Literature DB >> 18204330

The Cleveland Clinic PediPump: virtual fitting studies in children using three-dimensional reconstructions of cardiac computed tomography scans.

Diyar Saeed1, Yoshio Ootaki, Angela Noecker, Stephan Weber, William A Smith, Brian W Duncan, Kiyotaka Fukamachi.   

Abstract

The fitting of implantable ventricular assist devices (VADs) is a particular challenge for pediatric patients and patients with small body surface area. The purpose of this study was to determine optimal placement of the PediPump, a pediatric VAD currently under development at the Cleveland Clinic, using virtual three-dimensional (3D) on-screen models. Digital models were created from computed tomographic datasets of pediatric hearts using commercially available 3D image processing software. Pixels representing the myocardium, great vessels, sternum, and rib cage were selected and rendered as on-screen models (n = 13) from pediatric patients with or without congenital heart disease (median age 42 months; range 2 days to 13 years 11 months). Using 3D model manipulation software, virtual models of the PediPump (70 x 10 mm) were combined on-screen with the anatomic models. A variety of virtual fitting options were created, which allowed easy detection of device interference with surrounding tissues. Generation of 3D on-screen models of cardiac structures in relation to PediPump placement has provided useful preliminary fitting information, which is being used to guide further development of this device.

Entities:  

Mesh:

Year:  2008        PMID: 18204330     DOI: 10.1097/MAT.0b013e31815b4495

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  5 in total

1.  The national heart, lung, and blood institute pediatric circulatory support program: a summary of the 5-year experience.

Authors:  J Timothy Baldwin; Harvey S Borovetz; Brian W Duncan; Mark J Gartner; Robert K Jarvik; William J Weiss
Journal:  Circulation       Date:  2011-03-22       Impact factor: 29.690

2.  Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart.

Authors:  Jamshid H Karimov; Robert J Steffen; Nicole Byram; Gengo Sunagawa; David Horvath; Vincent Cruz; Leonard A R Golding; Kiyotaka Fukamachi; Nader Moazami
Journal:  ASAIO J       Date:  2015 Jul-Aug       Impact factor: 2.872

3.  Patient-specific surgical planning and hemodynamic computational fluid dynamics optimization through free-form haptic anatomy editing tool (SURGEM).

Authors:  Kerem Pekkan; Brian Whited; Kirk Kanter; Shiva Sharma; Diane de Zelicourt; Kartik Sundareswaran; David Frakes; Jarek Rossignac; Ajit P Yoganathan
Journal:  Med Biol Eng Comput       Date:  2008-08-05       Impact factor: 2.602

4.  Mastoid cavity dimensions and shape: method of measurement and virtual fitting of implantable devices.

Authors:  Ophir Handzel; Haobing Wang; Jason Fiering; Jeffrey T Borenstein; Mark J Mescher; Erin E Leary Swan; Brian A Murphy; Zhiqiang Chen; Marcello Peppi; William F Sewell; Sharon G Kujawa; Michael J McKenna
Journal:  Audiol Neurootol       Date:  2009-04-15       Impact factor: 1.854

Review 5.  Innovative Modeling Techniques and 3D Printing in Patients with Left Ventricular Assist Devices: A Bridge from Bench to Clinical Practice.

Authors:  Rishi Thaker; Raquel Araujo-Gutierrez; Hernan G Marcos-Abdala; Tanushree Agrawal; Nadia Fida; Mahwash Kassi
Journal:  J Clin Med       Date:  2019-05-09       Impact factor: 4.241

  5 in total