Literature DB >> 18196809

Treatment planning for a small animal using Monte Carlo simulation.

James C L Chow1, Michael K K Leung.   

Abstract

The development of a small animal model for radiotherapy research requires a complete setup of customized imaging equipment, irradiators, and planning software that matches the sizes of the subjects. The purpose of this study is to develop and demonstrate the use of a flexible in-house research environment for treatment planning on small animals. The software package, called DOSCTP, provides a user-friendly platform for DICOM computed tomography-based Monte Carlo dose calculation using the EGSnrcMP-based DOSXYZnrc code. Validation of the treatment planning was performed by comparing the dose distributions for simple photon beam geometries calculated through the Pinnacle3 treatment planning system and measurements. A treatment plan for a mouse based on a CT image set by a 360-deg photon arc is demonstrated. It is shown that it is possible to create 3D conformal treatment plans for small animals with consideration of inhomogeneities using small photon beam field sizes in the diameter range of 0.5-5 cm, with conformal dose covering the target volume while sparing the surrounding critical tissue. It is also found that Monte Carlo simulation is suitable to carry out treatment planning dose calculation for small animal anatomy with voxel size about one order of magnitude smaller than that of the human.

Entities:  

Mesh:

Year:  2007        PMID: 18196809     DOI: 10.1118/1.2805254

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

Review 1.  Hi-tech systems for in-vivo image-guided preclinical radiobiology.

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-12       Impact factor: 9.236

2.  Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy.

Authors:  Magdalena Bazalova; Hu Zhou; Paul J Keall; Edward E Graves
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

Review 3.  Some computer graphical user interfaces in radiation therapy.

Authors:  James C L Chow
Journal:  World J Radiol       Date:  2016-03-28

4.  Modality comparison for small animal radiotherapy: a simulation study.

Authors:  Magdalena Bazalova; Geoff Nelson; John M Noll; Edward E Graves
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

5.  Commissioning of a novel microCT/RT system for small animal conformal radiotherapy.

Authors:  Manuel Rodriguez; Hu Zhou; Paul Keall; Edward Graves
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

6.  Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators.

Authors:  Matthew D Belley; Chu Wang; Giao Nguyen; Rathnayaka Gunasingha; Nelson J Chao; Benny J Chen; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

7.  High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities.

Authors:  John Wong; Elwood Armour; Peter Kazanzides; Iulian Iordachita; Erik Tryggestad; Hua Deng; Mohammad Matinfar; Christopher Kennedy; Zejian Liu; Timothy Chan; Owen Gray; Frank Verhaegen; Todd McNutt; Eric Ford; Theodore L DeWeese
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-08-01       Impact factor: 7.038

8.  High throughput film dosimetry in homogeneous and heterogeneous media for a small animal irradiator.

Authors:  L Wack; W Ngwa; E Tryggestad; P Tsiamas; R Berbeco; S K Ng; J Hesser; P Zygmanski
Journal:  Phys Med       Date:  2013-03-17       Impact factor: 2.685

9.  A kernel-based dose calculation algorithm for kV photon beams with explicit handling of energy and material dependencies.

Authors:  Anna Merle Reinhart; Martin F Fast; Peter Ziegenhein; Simeon Nill; Uwe Oelfke
Journal:  Br J Radiol       Date:  2016-10-27       Impact factor: 3.039

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.