Literature DB >> 18196790

Joint model of motion and anatomy for PET image reconstruction.

Feng Qiao1, Tinsu Pan, John W Clark, Osama Mawlawi.   

Abstract

Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respiratory motion. In this article, we present a joint model of both motion and anatomical information by integrating a motion-incorporated PET imaging system model with an anatomy-based maximum a posteriori image reconstruction algorithm. The mismatched anatomical information due to motion can thus be effectively utilized through this joint model. A computer simulation and a phantom study were conducted to assess the efficacy of the joint model, whereby motion and anatomical information were either modeled separately or combined. The reconstructed images in each case were compared to corresponding reference images obtained using a quadratic image prior based maximum a posteriori reconstruction algorithm for quantitative accuracy. Results of these studies indicated that while modeling anatomical information or motion alone improved the PET image quantitation accuracy, a larger improvement in accuracy was achieved when using the joint model. In the computer simulation study and using similar image noise levels, the improvement in quantitation accuracy compared to the reference images was 5.3% and 19.8% when using anatomical or motion information alone, respectively, and 35.5% when using the joint model. In the phantom study, these results were 5.6%, 5.8%, and 19.8%, respectively. These results suggest that motion compensation is important in order to effectively utilize anatomical information in chest imaging using PET. The joint motion-anatomy model presented in this paper provides a promising solution to this problem.

Mesh:

Year:  2007        PMID: 18196790     DOI: 10.1118/1.2804721

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

Review 1.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

2.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-12       Impact factor: 9.236

3.  Respiratory motion correction for quantitative PET/CT using all detected events with internal-external motion correlation.

Authors:  Chi Liu; Adam M Alessio; Paul E Kinahan
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

4.  Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211.

Authors:  Mathieu Hatt; John A Lee; Charles R Schmidtlein; Issam El Naqa; Curtis Caldwell; Elisabetta De Bernardi; Wei Lu; Shiva Das; Xavier Geets; Vincent Gregoire; Robert Jeraj; Michael P MacManus; Osama R Mawlawi; Ursula Nestle; Andrei B Pugachev; Heiko Schöder; Tony Shepherd; Emiliano Spezi; Dimitris Visvikis; Habib Zaidi; Assen S Kirov
Journal:  Med Phys       Date:  2017-05-18       Impact factor: 4.071

5.  Pulmonary imaging using respiratory motion compensated simultaneous PET/MR.

Authors:  Joyita Dutta; Chuan Huang; Quanzheng Li; Georges El Fakhri
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

6.  Ultra-low dose CT attenuation correction for PET/CT.

Authors:  Ting Xia; Adam M Alessio; Bruno De Man; Ravindra Manjeshwar; Evren Asma; Paul E Kinahan
Journal:  Phys Med Biol       Date:  2011-12-09       Impact factor: 3.609

7.  Quiescent period respiratory gating for PET/CT.

Authors:  Chi Liu; Adam Alessio; Larry Pierce; Kris Thielemans; Scott Wollenweber; Alexander Ganin; Paul Kinahan
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

Review 8.  Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

Authors:  Geoffrey D Hugo; Mihaela Rosu
Journal:  Z Med Phys       Date:  2012-07-10       Impact factor: 4.820

9.  Image reconstruction for PET/CT scanners: past achievements and future challenges.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  Imaging Med       Date:  2010-10-01

10.  The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging.

Authors:  Chi Liu; Larry A Pierce; Adam M Alessio; Paul E Kinahan
Journal:  Phys Med Biol       Date:  2009-11-20       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.