Literature DB >> 18187352

Resonator with reduced sample heating and increased homogeneity for solid-state NMR.

Alexander Krahn1, Uwe Priller, Lyndon Emsley, Frank Engelke.   

Abstract

In the application of solid-state NMR to many systems, the presence of radiofrequency (rf) electric fields inside classical solenoidal coils causes heating of lossy samples. In particular, this is critical for proteins in ionic buffers. Rf sample heating increases proportional to frequency which may result in the need to reduce the rf pulse power to prevent partial or total sample deterioration. In the present paper, we propose a multifrequency-tunable NMR resonator where the sample is electrically shielded from the NMR coil by a conductive sheet that increases the magneto-electric ratio. Expressions for the B1 efficiency as function of magnetic and electric filling factors are derived that allow a direct comparison of different resonators. Rf efficiency, homogeneity, signal-to-noise, and rf sample heating are compared. NMR spectra at 700MHz on ethylene glycol, glycine, and a model protein were acquired to compare the resonators under realistic experimental conditions.

Entities:  

Mesh:

Year:  2008        PMID: 18187352     DOI: 10.1016/j.jmr.2007.12.004

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  8 in total

1.  3D-printed dissolvable inserts for efficient and customizable fabrication of NMR transceiver coils.

Authors:  Jessica I Kelz; John E Kelly; Rachel W Martin
Journal:  J Magn Reson       Date:  2019-06-17       Impact factor: 2.229

Review 2.  Probes for high field solid-state NMR of lossy biological samples.

Authors:  Christopher V Grant; Chin H Wu; Stanley J Opella
Journal:  J Magn Reson       Date:  2010-03-31       Impact factor: 2.229

3.  Faraday shields within a solenoidal coil to reduce sample heating: numerical comparison of designs and experimental verification.

Authors:  BuSik Park; Thomas Neuberger; Andrew G Webb; Don C Bigler; Christopher M Collins
Journal:  J Magn Reson       Date:  2009-10-04       Impact factor: 2.229

4.  A low-E magic angle spinning probe for biological solid state NMR at 750 MHz.

Authors:  Seth A McNeill; Peter L Gor'kov; Kiran Shetty; William W Brey; Joanna R Long
Journal:  J Magn Reson       Date:  2008-12-14       Impact factor: 2.229

5.  A Modified Alderman-Grant Coil makes possible an efficient cross-coil probe for high field solid-state NMR of lossy biological samples.

Authors:  Christopher V Grant; Yuan Yang; Mira Glibowicka; Chin H Wu; Sang Ho Park; Charles M Deber; Stanley J Opella
Journal:  J Magn Reson       Date:  2009-08-15       Impact factor: 2.229

6.  Heat management strategies for solid-state NMR of functional proteins.

Authors:  Daniel J Fowler; Michael J Harris; Lynmarie K Thompson
Journal:  J Magn Reson       Date:  2012-09       Impact factor: 2.229

7.  A strip-shield improves the efficiency of a solenoid coil in probes for high-field solid-state NMR of lossy biological samples.

Authors:  Chin H Wu; Christopher V Grant; Gabriel A Cook; Sang Ho Park; Stanley J Opella
Journal:  J Magn Reson       Date:  2009-06-09       Impact factor: 2.229

8.  A method to separate conservative and magnetically-induced electric fields in calculations for MRI and MRS in electrically-small samples.

Authors:  BuSik Park; Andrew G Webb; Christopher M Collins
Journal:  J Magn Reson       Date:  2009-05-21       Impact factor: 2.229

  8 in total