Abstract

The mechanical behavior of human liver has been characterized with aspiration experiments. Measurements have been performed in vivo under sterile conditions during open surgery. Twenty-three measurements on six healthy human livers were performed using the same loading history for each test, so to allow a direct comparison of the measured deformations. The measurement results are reported and the experimental uncertainties evaluated. One of the main objectives of the present paper is to share information on the in vivo mechanical response of human liver with the biomechanics research community: the present data can be used for mechanical model development and validation purposes. The parameters of a quasi-linear viscoelastic model have been determined from the experimental data by means of inverse finite element calculations. The corresponding linear elastic modulus is compared with values from the literature. In particular, a significant discrepancy has been found with respect to the values proposed by Carter et al. [Carter, F.J., Frank, T.G., Davies, P.J., McLean, D., Cuschieri, A., 2001. Measurement and modelling of the compliance of human and porcine organs. Medical Image Analysis 5, 231-236] and the reasons for this difference are discussed. The predictive capabilities of the quasi-linear viscoelastic model and the Rubin Bodner non-linear elastic-viscoplastic model are compared with respect to the tissue response in repeated aspiration cycles. Finally, for demonstration purposes, the constitutive model corresponding to the "average" liver response has been implemented into a finite element whole liver model and used for simulations related to liver surgery.

Entities:  

Mesh:

Year:  2007        PMID: 18171633     DOI: 10.1016/j.media.2007.10.001

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  28 in total

1.  Robotic palpation and mechanical property characterization for abnormal tissue localization.

Authors:  Bummo Ahn; Yeongjin Kim; Cheol Kyu Oh; Jung Kim
Journal:  Med Biol Eng Comput       Date:  2012-07-07       Impact factor: 2.602

2.  The design of in vitro liver sinusoid mimics using chitosan-hyaluronic acid polyelectrolyte multilayers.

Authors:  Yeonhee Kim; Adam L Larkin; Richey M Davis; Padmavathy Rajagopalan
Journal:  Tissue Eng Part A       Date:  2010-09       Impact factor: 3.845

3.  Development of in vivo constitutive models for liver: application to surgical simulation.

Authors:  Kevin Lister; Zhan Gao; Jaydev P Desai
Journal:  Ann Biomed Eng       Date:  2010-12-16       Impact factor: 3.934

Review 4.  The Role of the Microenvironment in Controlling the Fate of Bioprinted Stem Cells.

Authors:  Lauren N West-Livingston; Jihoon Park; Sang Jin Lee; Anthony Atala; James J Yoo
Journal:  Chem Rev       Date:  2020-06-19       Impact factor: 60.622

5.  Characterization of a hyper-viscoelastic phantom mimicking biological soft tissue using an abdominal pneumatic driver with magnetic resonance elastography (MRE).

Authors:  Gwladys E Leclerc; Laëtitia Debernard; Félix Foucart; Ludovic Robert; Kay M Pelletier; Fabrice Charleux; Richard Ehman; Marie-Christine Ho Ba Tho; Sabine F Bensamoun
Journal:  J Biomech       Date:  2012-01-28       Impact factor: 2.712

Review 6.  Advances in Micropipette Aspiration: Applications in Cell Biomechanics, Models, and Extended Studies.

Authors:  Blanca González-Bermúdez; Gustavo V Guinea; Gustavo R Plaza
Journal:  Biophys J       Date:  2019-01-07       Impact factor: 4.033

7.  Designing a multicellular organotypic 3D liver model with a detachable, nanoscale polymeric Space of Disse.

Authors:  Adam L Larkin; Richard R Rodrigues; T M Murali; Padmavathy Rajagopalan
Journal:  Tissue Eng Part C Methods       Date:  2013-06-22       Impact factor: 3.056

8.  A Physics-driven Neural Networks-based Simulation System (PhyNNeSS) for multimodal interactive virtual environments involving nonlinear deformable objects.

Authors:  Suvranu De; Dhannanjay Deo; Ganesh Sankaranarayanan; Venkata S Arikatla
Journal:  Presence (Camb)       Date:  2011-08

9.  Constitutive modeling of porcine liver in indentation using 3D ultrasound imaging.

Authors:  P Jordan; S Socrate; T E Zickler; R D Howe
Journal:  J Mech Behav Biomed Mater       Date:  2008-09-06

10.  Robotic mechanical localization of prostate cancer correlates with magnetic resonance imaging scans.

Authors:  Tae Young Shin; Yeong Jin Kim; Sey Kiat Lim; Jung Kim; Koon Ho Rha
Journal:  Yonsei Med J       Date:  2013-07       Impact factor: 2.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.