Literature DB >> 18165028

The influence of acetabular component position on wear in total hip arthroplasty.

Zhinian Wan1, Myriam Boutary, Lawrence D Dorr.   

Abstract

Our experience has implicated cup inclination as an important factor in wear, whereas others have suggested that the hip center of rotation (COR) must be closely reestablished to reduce wear. We conducted a retrospective study to determine the relative importance of these 2 factors. One hundred thirty-nine total hip arthroplasties were studied after a mean follow-up of 9.2 years (range, 6-3 years). Forty-nine of 139 operated hips had a contralateral normal hip, which allowed the most accurate measurement of the influence of change in the COR. Wear was related to the inclination of the cup but not to a change in the COR. Secondarily, wear was less with a ceramic-polyethylene polyarticular surface than with metal-polyethylene. The importance of this data is related to cup implantation techniques. The hip COR can be moved superiorly and/or medially to permit cup inclination below 45 degrees with correct cup coverage.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18165028     DOI: 10.1016/j.arth.2007.06.008

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  52 in total

1.  Causes of failure of ceramic-on-ceramic and metal-on-metal hip arthroplasties.

Authors:  Manny Porat; Javad Parvizi; Peter F Sharkey; Keith R Berend; Adolph V Lombardi; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Measuring acetabular component version after THA: CT or plain radiograph?

Authors:  Benjamin McArthur; Michael Cross; Christina Geatrakas; David Mayman; Bernard Ghelman
Journal:  Clin Orthop Relat Res       Date:  2012-03-01       Impact factor: 4.176

3.  Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs.

Authors:  Maximilian Haenle; Wolfram Mittelmeier; Rodrigo Barbano; Klaus Wörtler; Roger Scholz; Rainer Bader
Journal:  Surg Radiol Anat       Date:  2010-06-25       Impact factor: 1.246

4.  How does pelvic rotation or tilt affect radiographic measurement of acetabular component inclination angle during THA?

Authors:  Chris R Mellano; Andrew I Spitzer
Journal:  J Orthop       Date:  2015-06-23

5.  Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study.

Authors:  Peter K Sculco; Alexander S McLawhorn; Kaitlin M Carroll; Benjamin A McArthur; David J Mayman
Journal:  HSS J       Date:  2015-10-19

6.  Combined anteversion technique reduced the dislocation in cementless total hip arthroplasty.

Authors:  Yasuharu Nakashima; Masanobu Hirata; Mio Akiyama; Takashi Itokawa; Takuaki Yamamoto; Goro Motomura; Masanobu Ohishi; Satoshi Hamai; Yukihide Iwamoto
Journal:  Int Orthop       Date:  2013-09-13       Impact factor: 3.075

7.  Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty.

Authors:  Jiri Gallo; Vitezslav Havranek; Jana Zapletalova
Journal:  Int Orthop       Date:  2009-02-13       Impact factor: 3.075

8.  Combined anteversion technique for total hip arthroplasty.

Authors:  Lawrence D Dorr; Aamer Malik; Manish Dastane; Zhinian Wan
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

9.  A more reliable method to assess acetabular component position.

Authors:  John V Tiberi; Nicholas Pulos; Michael Kertzner; Thomas P Schmalzried; Thomas P Schmlazried
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

10.  Does the surgical approach influence the implant alignment in total hip arthroplasty? Comparative study between the direct anterior and the anterolateral approaches in the supine position.

Authors:  Yuya Kawarai; Satoshi Iida; Junichi Nakamura; Yoshiyuki Shinada; Chiho Suzuki; Seiji Ohtori
Journal:  Int Orthop       Date:  2017-05-31       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.