Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period.

Olfa Hamzaoui1, Xavier Monnet, Christian Richard, David Osman, Denis Chemla, Jean-Louis Teboul.   

Abstract

OBJECTIVES: To examine whether the agreement between pulse contour and transpulmonary thermodilution cardiac index (CI) measurements is altered by changes in vascular tone within an up to 6-hr calibration-free period.
DESIGN: Observational study.
SETTING: Medical intensive care unit of a university hospital. PATIENTS: Fifty-nine critically ill patients.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Data from 59 critically ill patients equipped with a PiCCO device were retrospectively analyzed. The database contained the transpulmonary thermodilution CI (CI(T)) value obtained at each time point the device was calibrated and the pulse contour CI (CI(PC)) value recorded immediately before this time point. Seven subsets of CI pairs were defined according to intervals of time elapsed from the previous calibration (within the first 30 mins, between 30 mins and 1 hr, and every hour up to 6 hrs). In the whole set of 400 CI pairs, CI(PC) correlated with CI(T) (r2 = .68, p < .001). The bias +/- SD was 0.12 +/- 0.61 L/min/m2, and the percentage error was 35%. Among the seven time-interval subsets, the percentage error was <30% only in the two first ones (27% and 26%, respectively). When changes in systemic vascular resistance by >15% occurred (129 times), CI(PC) correlated with CI(T) (r2 = .64), the bias +/- SD was 0.12 +/- 0.62 L/min/m2, and the percentage error was 36%. In the subset of CI pairs recorded within the 1-hr calibration-free period while vascular resistance changed by >15% (n = 32), the bias +/- SD was 0.04 +/- 0.47 L/min/m and the percentage error was 29%.
CONCLUSIONS: Our study in critically ill patients suggests that the agreement between pulse contour cardiac output and transpulmonary thermodilution cardiac output was not significantly influenced by changes in vascular tone. However, after a 1-hr calibration-free period, recalibration may be encouraged. Such a procedure provides helpful information drawn from other thermodilution-derived variables.

Entities:  

Mesh:

Year:  2008        PMID: 18091547     DOI: 10.1097/01.CCM.OB013E318161FEC4

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  48 in total

1.  Can the "FloTrac" really track flow in septic patients?

Authors:  Xavier Monnet; Daniel Lahner
Journal:  Intensive Care Med       Date:  2010-12-10       Impact factor: 17.440

Review 2.  Reproducibility of transpulmonary thermodilution cardiac output measurements in clinical practice: a systematic review.

Authors:  Raphaël Giraud; Nils Siegenthaler; Paolo Merlani; Karim Bendjelid
Journal:  J Clin Monit Comput       Date:  2016-01-11       Impact factor: 2.502

Review 3.  Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis.

Authors:  Xavier Monnet; Paul Marik; Jean-Louis Teboul
Journal:  Intensive Care Med       Date:  2016-01-29       Impact factor: 17.440

Review 4.  Is there a role for invasive hemodynamic monitoring in acute heart failure management?

Authors:  Daniel De Backer
Journal:  Curr Heart Fail Rep       Date:  2015-06

5.  Can changes in arterial pressure be used to detect changes in cardiac index during fluid challenge in patients with septic shock?

Authors:  Charalampos Pierrakos; Dimitrios Velissaris; Sabino Scolletta; Sarah Heenen; Daniel De Backer; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2012-01-26       Impact factor: 17.440

Review 6.  Advanced hemodynamic monitoring: principles and practice in neurocritical care.

Authors:  Christos Lazaridis
Journal:  Neurocrit Care       Date:  2012-02       Impact factor: 3.210

Review 7.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

8.  An autocalibrating algorithm for non-invasive cardiac output determination based on the analysis of an arterial pressure waveform recorded with radial artery applanation tonometry: a proof of concept pilot analysis.

Authors:  Bernd Saugel; Agnes S Meidert; Nicolas Langwieser; Julia Y Wagner; Florian Fassio; Alexander Hapfelmeier; Luisa M Prechtl; Wolfgang Huber; Roland M Schmid; Oliver Gödje
Journal:  J Clin Monit Comput       Date:  2013-12-10       Impact factor: 2.502

Review 9.  Alternatives to the Swan-Ganz catheter.

Authors:  Daniel De Backer; Jan Bakker; Maurizio Cecconi; Ludhmila Hajjar; Da Wei Liu; Suzanna Lobo; Xavier Monnet; Andrea Morelli; Sheila Neinan Myatra; Azriel Perel; Michael R Pinsky; Bernd Saugel; Jean-Louis Teboul; Antoine Vieillard-Baron; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2018-05-03       Impact factor: 17.440

10.  Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients.

Authors:  Christopher G Scully; Shanti Gomatam; Shawn Forrest; David G Strauss
Journal:  J Clin Monit Comput       Date:  2015-08-19       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.