Literature DB >> 18091458

The clinical utility of dynamic contour tonometry and ocular pulse amplitude.

Jennifer S Weizer1, Sanjay Asrani, Sandra S Stinnett, Leon W Herndon.   

Abstract

PURPOSE: To determine if ocular pulse amplitude (OPA) as measured by dynamic contour tonometry (DCT) is related to severity of glaucoma, and if intraocular pressure (IOP) as measured by DCT is related to central corneal thickness (CCT).
METHODS: Patients were selected from the Duke Eye Center glaucoma clinic. Fifty-five eyes of 32 patients were included; right and left eyes were analyzed separately. CCT, OPA, DCT IOP, Goldmann applanation tonometry (GAT), Tonopen applanation tonometry (TAT), and systemic blood pressure were measured. Advanced Glaucoma Intervention Study score and mean deviation of visual field, and vertical and horizontal cup-disc ratios were recorded in a masked manner. Descriptive statistics were obtained, and OPA, DCT IOP, GAT, and TAT underwent univariate analyses to assess for relationships with predictor variables.
RESULTS: OPA, DCT IOP, GAT, and TAT were positively associated with CCT and with having no surgical intervention for right and left eyes, and were negatively associated with vertical and horizontal cup-disc ratios.
CONCLUSIONS: Increased OPA seems to correlate with less severe glaucoma and with increased CCT. DCT IOP seems to be affected by CCT along with GAT and TAT.

Entities:  

Mesh:

Year:  2007        PMID: 18091458     DOI: 10.1097/IJG.0b013e31806ab2fe

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  15 in total

1.  Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver.

Authors:  Umit Aykan; Mesut Erdurmus; Burhan Yilmaz; Ahmet Hamdi Bilge
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-24       Impact factor: 3.117

2.  [Mobile intraocular pressure measurement. From palpation to initial clinical experience with the handheld dynamic contour tonometer].

Authors:  U Schmid; C Kniestedt
Journal:  Ophthalmologe       Date:  2010-07       Impact factor: 1.059

3.  Goldmann applanation tonometry and dynamic contour tonometry in eyes with elevated intraocular pressure (IOP): comparison in the same eyes after subsequent medical normalization of IOP.

Authors:  Chungkwon Yoo; Young Sub Eom; Yong Yeon Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-07-22       Impact factor: 3.117

4.  Ocular pulse amplitude and retrobulbar blood flow change in dipper and non-dipper individuals.

Authors:  R Karadag; U C Keskin; A Koktener; Y Selcoki; I F Hepsen; M Kanbay
Journal:  Eye (Lond)       Date:  2011-03-18       Impact factor: 3.775

5.  Mechanical interferometry of nanoscale motion and local mechanical properties of living zebrafish embryos.

Authors:  Jason Reed; Siddarth Ramakrishnan; Joanna Schmit; James K Gimzewski
Journal:  ACS Nano       Date:  2009-08-25       Impact factor: 15.881

6.  Evaluation of a contact lens-embedded sensor for intraocular pressure measurement.

Authors:  Michael D Twa; Cynthia J Roberts; Huikai J Karol; Ashraf M Mahmoud; Paul A Weber; Robert H Small
Journal:  J Glaucoma       Date:  2010-08       Impact factor: 2.503

7.  Update and critical appraisal of combined timolol and carbonic anhydrase inhibitors and the effect on ocular blood flow in glaucoma patients.

Authors:  Adam M Moss; Alon Harris; Brent Siesky; Deepam Rusia; Kathleen M Williamson; Yochai Shoshani
Journal:  Clin Ophthalmol       Date:  2010-04-26

8.  Dynamic contour tonometry in asymmetric glaucoma patients.

Authors:  Emilio Rintaro Suzuki; Cibele Lima Belico Suzuki; Danielle Carlier; Daniele Penha; Marta Dos Anjos Rodrigues Parchen; Wagner Duarte Batista; Joao Agostini Netto
Journal:  Clin Ophthalmol       Date:  2012-04-11

9.  Dynamic contour tonometry in primary open angle glaucoma and pseudoexfoliation glaucoma: factors associated with intraocular pressure and ocular pulse amplitude.

Authors:  Sasan Moghimi; Hamidreza Torabi; Ghasem Fakhraie; Nariman Nassiri; Massood Mohammadi
Journal:  Middle East Afr J Ophthalmol       Date:  2013 Apr-Jun

10.  Efficacy of a contact lens sensor for monitoring 24-h intraocular pressure related patterns.

Authors:  Kaweh Mansouri; Robert N Weinreb; John H K Liu
Journal:  PLoS One       Date:  2015-05-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.