Literature DB >> 18090469

Minimum 6-year followup of highly cross-linked polyethylene in THA.

Charles R Bragdon1, Young Min Kwon, Jeffrey A Geller, Meridith E Greene, Andrew A Freiberg, William H Harris, Henrik Malchau.   

Abstract

To reduce wear rates and particulate debris, highly cross-linked polyethylene has been in use in total hip arthroplasty for 8 years. We designed this followup study to primarily determine the total penetration rate of the femoral head and the steady-state wear rate of cross-linked polyethylene in patients undergoing primary total hip arthroplasty. We retrospectively reviewed data from 182 patients (200 hips) with a minimum 6-year followup (mean, 6.9 years; range, 6-8 years) and an average age of 60.2 years at surgery. The average Harris hip score, University of California-Los Angeles activity score, and WOMAC score were 91.1, 6.3, and 11.3, respectively. Radiographic evaluation showed no evidence of loosening or osteolytic lesions around the cup or stem. No revisions were performed for polyethylene wear or liner fracture. The average steady-state wear rate was -0.002 +/- 0.01 mm per year and -0.026 +/- 0.13 mm per year for 28-mm and 32-mm head sizes, respectively. We observed no correlation between the total wear rate and femoral head size, brand of polyethylene, age, gender, primary diagnosis, mode of fixation, surgical approach, University of California-Los Angeles activity score, Harris hip score, or WOMAC. Highly cross-linked polyethylene liners are associated with excellent midterm clinical, radiographic, and wear results in this group of patients.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18090469     DOI: 10.1097/BLO.0b013e31815760b1

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  17 in total

1.  Is routine mid-term total hip arthroplasty surveillance beneficial?

Authors:  James A Keeney; Bradley S Ellison; William J Maloney; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2012-06-06       Impact factor: 4.176

2.  Continued improved wear with an annealed highly cross-linked polyethylene.

Authors:  William N Capello; James A D'Antonio; Rama Ramakrishnan; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2010-09-16       Impact factor: 4.176

3.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

4.  Wear is reduced in THA performed with highly cross-linked polyethylene.

Authors:  Burak Beksaç; Antonio Salas; Alejandro González Della Valle; Eduardo A Salvati
Journal:  Clin Orthop Relat Res       Date:  2008-12-12       Impact factor: 4.176

5.  The first 50 years of total hip arthroplasty: lessons learned.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2008-11-04       Impact factor: 4.176

6.  Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

Authors:  Jeffrey T Hodrick; Erik P Severson; Deborah S McAlister; Brian Dahl; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

7.  THA with highly cross-linked polyethylene in patients 50 years or younger.

Authors:  Derek S Shia; John C Clohisy; Mark F Schinsky; John M Martell; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176

8.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

9.  Cross-linked compared with historical polyethylene in THA: an 8-year clinical study.

Authors:  Carel H Geerdink; Bernd Grimm; Wendy Vencken; Ide C Heyligers; Alphons J Tonino
Journal:  Clin Orthop Relat Res       Date:  2008-11-22       Impact factor: 4.176

10.  UHMWPE for arthroplasty: past or future?

Authors:  Elena Maria Brach Del Prever; Alessandro Bistolfi; Pierangiola Bracco; Luigi Costa
Journal:  J Orthop Traumatol       Date:  2008-12-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.