Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: intravascular ultrasound results from ENDEAVOR III.

Akiyoshi Miyazawa1, Junya Ako, Yoichiro Hongo, Seung-Ho Hur, Ichizo Tsujino, Brian K Courtney, Ali H M Hassan, David E Kandzari, Yasuhiro Honda, Peter J Fitzgerald.   

Abstract

BACKGROUND: The purpose of this study was to investigate the vascular response of zotarolimus-eluting stent (ZES) and sirolimus-eluting stent (SES) using serial intravascular ultrasound (IVUS).
METHODS: Data were obtained from the Endeavor Drug-Eluting Coronary Stent System Versus the Center Siromlimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (ENDEAVOR) III trial, a randomized study comparing ZES and SES for the treatment of de novo native coronary artery lesions. Serial (baseline and 8-month follow-up) IVUS was available in 258 patients (190 ZES, 68 SES).
RESULTS: At 8 months, ZES had greater percentage of neointimal volume index (ZES 1.1 +/- 0.8 mm3/mm vs SES 0.2 +/- 0.1 mm3/mm, P < .01), resulting in smaller lumen volume index (6.0 +/- 2.0 mm3/mm vs 7.0 +/- 2.1 mm3/mm, P < .05). Zotarolimus-eluting stents showed larger IVUS-detectable neointimal coverage over stent surface (50.2% vs 10.5%, P < .01) and greater mean neointimal thickness (0.19 +/- 0.07 mm vs 0.10 +/- 0.06 mm, P < .01). Zotarolimus-eluting stents had a significantly lower incidence of late-acquired incomplete stent apposition.
CONCLUSIONS: Zotarolimus-eluting stent is associated with a significantly greater amount of neointimal hyperplasia compared with SES. This amount of hyperplasia in ZES is distributed throughout the stent at 8-month follow-up.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18082499     DOI: 10.1016/j.ahj.2007.08.008

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  10 in total

1.  Comparison of vascular remodeling in patients treated with sirolimus-versus zotarolimus-eluting stent following acute myocardial infarction.

Authors:  Ki-Woon Kang; Young-Guk Ko; Dong-Ho Shin; Jung-Sun Kim; Byeong-Keuk Kim; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Clin Cardiol       Date:  2011-12-12       Impact factor: 2.882

2.  In vitro study of dual drug-eluting stents with locally focused sirolimus and atorvastatin release.

Authors:  Svea Petersen; Janine Hussner; Thomas Reske; Niels Grabow; Volkmar Senz; Robert Begunk; Daniela Arbeiter; Heyo K Kroemer; Klaus-Peter Schmitz; Henriette E Meyer zu Schwabedissen; Katrin Sternberg
Journal:  J Mater Sci Mater Med       Date:  2013-07-12       Impact factor: 3.896

3.  Optical coherence tomographic comparison of neointimal coverage between sirolimus- and resolute zotarolimus-eluting stents at 9 months after stent implantation.

Authors:  Jung-Sun Kim; Jin-Sun Kim; Dong-Ho Shin; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2011-08-21       Impact factor: 2.357

4.  Interventional cardiology: Outcomes in coronary stent trials--1 year is not enough.

Authors:  Vasileios F Panoulas; Antonio Colombo
Journal:  Nat Rev Cardiol       Date:  2014-05-06       Impact factor: 32.419

Review 5.  Recent Advances in Stent Technology: Do They Reduce Cardiovascular Events?

Authors:  Allen J Weiss; Marta Lorente-Ros; Ashish Correa; Nitin Barman; Jacqueline E Tamis-Holland
Journal:  Curr Atheroscler Rep       Date:  2022-07-11       Impact factor: 5.967

6.  Comparison of neointimal hyperplasia and peri-stent vascular remodeling after implantation of everolimus-eluting versus sirolimus-eluting stents: intravascular ultrasound results from the EXCELLENT study.

Authors:  Young-Guk Ko; Dong-Ho Shin; Jung-Sun Kim; Byeong-Keuk Kim; Donghoon Choi; Myeong-Ki Hong; Hyeon-Cheol Gwon; Taehoon Ahn; In-Ho Chae; Jung-Han Yoon; Hyo-Soo Kim; Yangsoo Jang
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-03       Impact factor: 2.357

7.  The initial extent of malapposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography.

Authors:  Ung Kim; Jung-Sun Kim; Jin-Sun Kim; Jung-Myung Lee; Jung-Woo Son; Jaedeok Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang
Journal:  Yonsei Med J       Date:  2010-05       Impact factor: 2.759

8.  Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents.

Authors:  J-S Kim; I-K Jang; J-S Kim; T H Kim; M Takano; T Kume; N W Hur; Y-G Ko; D Choi; M-K Hong; Y Jang
Journal:  Heart       Date:  2009-06-16       Impact factor: 5.994

9.  Comparison of zotarolimus-eluting and sirolimus-eluting coronary stents: a study from the Western Denmark Heart Registry.

Authors:  Michael Maeng; Lisette Okkels Jensen; Anne Kaltoft; Hans-Henrik Tilsted; Evald Høj Christiansen; Per Thayssen; Morten Madsen; Henrik Toft Sørensen; Jens Flensted Lassen; Leif Thuesen
Journal:  BMC Cardiovasc Disord       Date:  2012-10-02       Impact factor: 2.298

10.  Randomised trial of the comparison of drug-eluting stents in patients with diabetes: OCT DES trial.

Authors:  Stephen Hamshere; Alex Byrne; Tawfiq Choudhury; Sean M Gallagher; Krishnaraj S Rathod; Julia Lungley; Charles J Knight; Akhil Kapur; Daniel A Jones; Anthony Mathur
Journal:  Open Heart       Date:  2018-04-05