Literature DB >> 35821187

Recent Advances in Stent Technology: Do They Reduce Cardiovascular Events?

Allen J Weiss1, Marta Lorente-Ros2, Ashish Correa3, Nitin Barman3, Jacqueline E Tamis-Holland4.   

Abstract

PURPOSE OF REVIEW: Drug-eluting stents are used in nearly all cases of percutaneous coronary revascularization and have been shown to be superior to balloon angioplasty or bare metal stents. The designs of these stents are continually evolving to maximize efficacy and safety. RECENT
FINDINGS: This review outlines the important components of a drug-eluting stent and highlights the changes in stent design that have led to the optimization of clinical outcomes. Most stents used in contemporary times are thin strut, durable polymer drug-eluting stents (DES) that elute either everolimus or zotarolimus. Newer DES designs incorporating bioresorbable polymers or ultrathin struts have shown encouraging safety and efficacy profiles. DES are essential for the management of patients with obstructive coronary artery disease and are used in most coronary interventions. Changes in stent designs over the past 30 years reflect the ongoing need to address the limitations of earlier stents aimed to improve patient outcomes.
© 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  Bioresorbable polymer; Drug-eluting stent; Drug-eluting stent architecture; Drug-eluting stent technology; Percutaneous coronary intervention; Ultrathin struts

Mesh:

Substances:

Year:  2022        PMID: 35821187     DOI: 10.1007/s11883-022-01049-z

Source DB:  PubMed          Journal:  Curr Atheroscler Rep        ISSN: 1523-3804            Impact factor:   5.967


  71 in total

1.  Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study.

Authors:  R Hoffmann; G S Mintz; G R Dussaillant; J J Popma; A D Pichard; L F Satler; K M Kent; J Griffin; M B Leon
Journal:  Circulation       Date:  1996-09-15       Impact factor: 29.690

Review 2.  Restenosis after successful coronary angioplasty. Pathophysiology and prevention.

Authors:  W McBride; R A Lange; L D Hillis
Journal:  N Engl J Med       Date:  1988-06-30       Impact factor: 91.245

3.  Transluminal dilatation of coronary-artery stenosis.

Authors:  A Gruntzig
Journal:  Lancet       Date:  1978-02-04       Impact factor: 79.321

4.  In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia.

Authors:  R Kornowski; M K Hong; F O Tio; O Bramwell; H Wu; M B Leon
Journal:  J Am Coll Cardiol       Date:  1998-01       Impact factor: 24.094

5.  A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group.

Authors:  P W Serruys; P de Jaegere; F Kiemeneij; C Macaya; W Rutsch; G Heyndrickx; H Emanuelsson; J Marco; V Legrand; P Materne
Journal:  N Engl J Med       Date:  1994-08-25       Impact factor: 91.245

6.  Restenosis after percutaneous transluminal coronary angioplasty (PTCA): a report from the PTCA Registry of the National Heart, Lung, and Blood Institute.

Authors:  D R Holmes; R E Vlietstra; H C Smith; G W Vetrovec; K M Kent; M J Cowley; D P Faxon; A R Gruentzig; S F Kelsey; K M Detre
Journal:  Am J Cardiol       Date:  1984-06-15       Impact factor: 2.778

7.  A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators.

Authors:  D L Fischman; M B Leon; D S Baim; R A Schatz; M P Savage; I Penn; K Detre; L Veltri; D Ricci; M Nobuyoshi
Journal:  N Engl J Med       Date:  1994-08-25       Impact factor: 91.245

8.  A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.

Authors:  Marie-Claude Morice; Patrick W Serruys; J Eduardo Sousa; Jean Fajadet; Ernesto Ban Hayashi; Marco Perin; Antonio Colombo; G Schuler; Paul Barragan; Giulio Guagliumi; Ferenc Molnàr; Robert Falotico
Journal:  N Engl J Med       Date:  2002-06-06       Impact factor: 91.245

9.  Clinical experience with the Palmaz-Schatz coronary stent. Initial results of a multicenter study.

Authors:  R A Schatz; D S Baim; M Leon; S G Ellis; S Goldberg; J W Hirshfeld; M W Cleman; H S Cabin; C Walker; J Stagg
Journal:  Circulation       Date:  1991-01       Impact factor: 29.690

10.  Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty.

Authors:  U Sigwart; J Puel; V Mirkovitch; F Joffre; L Kappenberger
Journal:  N Engl J Med       Date:  1987-03-19       Impact factor: 91.245

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.