Literature DB >> 15719976

Rest period duration of the coronary arteries: implications for magnetic resonance coronary angiography.

Guy Shechter1, Jon R Resar, Elliot R McVeigh.   

Abstract

Magnetic resonance (MR) and computed tomography coronary imaging is susceptible to artifacts caused by motion of the heart. The presence of rest periods during the cardiac and respiratory cycles suggests that images free of motion artifacts could be acquired. In this paper, we studied the rest period (RP) duration of the coronary arteries during a cardiac contraction and a tidal respiratory cycle. We also studied whether three MR motion correction methods could be used to increase the respiratory RP duration. Free breathing x-ray coronary angiograms were acquired in ten patients. The three-dimensional (3D) structure of the coronary arteries was reconstructed from a biplane acquisition using stereo reconstruction methods. The 3D motion of the arterial model was then recovered using an automatic motion tracking algorithm. The motion field was then decomposed into separate cardiac and respiratory components using a cardiac respiratory parametric model. For the proximal-to-middle segments of the right coronary artery (RCA), a cardiac RP (<1 mm 3D displacement) of 76+/-34 ms was measured at end systole (ES), and 65+/-42 ms in mid-diastole (MD). The cardiac RP was 80+/-25 ms at ES and 112+/-42 ms at MD for the proximal 5 cm of the left coronary tree. At end expiration, the respiratory RP (in percent of the respiratory period) was 26+/-8% for the RCA and 27+/-17% for the left coronary tree. Left coronary respiratory RP (<0.5 mm 3D displacement) increased with translation (32% of the respiratory period), rigid body (51%), and affine (79%) motion correction. The RCA respiratory RP using translational (27%) and rigid body (33%) motion correction were not statistically different from each other. Measurements of the cardiac and respiratory rest periods will improve our understanding of the temporal and spatial resolution constraints for coronary imaging.

Entities:  

Mesh:

Year:  2005        PMID: 15719976      PMCID: PMC2396325          DOI: 10.1118/1.1836291

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Free-breathing cardiac MR imaging: study of implications of respiratory motion--initial results.

Authors:  K Nehrke; P Börnert; D Manke; J C Böck
Journal:  Radiology       Date:  2001-09       Impact factor: 11.105

2.  Respiratory motion in coronary magnetic resonance angiography: a comparison of different motion models.

Authors:  Dirk Manke; Kay Nehrke; Peter Börnert; Peter Rösch; Olaf Dössel
Journal:  J Magn Reson Imaging       Date:  2002-06       Impact factor: 4.813

3.  Three-dimensional motion tracking of coronary arteries in biplane cineangiograms.

Authors:  Guy Shechter; Frédéric Devernay; Eve Coste-Manière; Arshed Quyyumi; Elliot R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  2003-04       Impact factor: 10.048

4.  Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model.

Authors:  Dirk Manke; Kay Nehrke; Peter Börnert
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

5.  Respiratory motion of the heart from free breathing coronary angiograms.

Authors:  Guy Shechter; Cengizhan Ozturk; Jon R Resar; Elliot R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  2004-08       Impact factor: 10.048

6.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

7.  Systolic time intervals in heart failure in man.

Authors:  A M Weissler; W S Harris; C D Schoenfeld
Journal:  Circulation       Date:  1968-02       Impact factor: 29.690

8.  Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography.

Authors:  Y Wang; E Vidan; G W Bergman
Journal:  Radiology       Date:  1999-12       Impact factor: 11.105

9.  Effect of respiration on cardiac motion determined by cineangiography. Implications concerning three-dimensional heart reconstruction using computer tomography.

Authors:  H G Bogren; B M Lantz; R R Miller; D T Mason
Journal:  Acta Radiol Diagn (Stockh)       Date:  1977-11

10.  Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging.

Authors:  Z A Fayad; V Fuster; J T Fallon; T Jayasundera; S G Worthley; G Helft; J G Aguinaldo; J J Badimon; S K Sharma
Journal:  Circulation       Date:  2000-08-01       Impact factor: 29.690

View more
  9 in total

1.  Cardiorespiratory-resolved magnetic resonance imaging: measuring respiratory modulation of cardiac function.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

2.  Displacement and velocity of the coronary arteries: cardiac and respiratory motion.

Authors:  Guy Shechter; Jon R Resar; Elliot R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  2006-03       Impact factor: 10.048

3.  Temporally targeted imaging method applied to ECG-gated computed tomography: preliminary phantom and in vivo experience.

Authors:  Brian E Nett; Shuai Leng; Joseph N Zambelli; Scott B Reeder; Michael A Speidel; Guang-Hong Chen
Journal:  Acad Radiol       Date:  2008-01       Impact factor: 3.173

4.  The compensation for asynchronous cardiac quiescence in coronary wall MR imaging.

Authors:  Kai Lin; Donald M Lloyd-Jones; Ying Liu; Biao Lu; Huadan Xue; Yining Wang; Debiao Li; James C Carr
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-30       Impact factor: 2.357

5.  Time-resolved analysis of coronary vein motion and cross-sectional area.

Authors:  Jonathan D Suever; Pierre J Watson; Robert L Eisner; Stamatios Lerakis; Robert E O'Donnell; John N Oshinski
Journal:  J Magn Reson Imaging       Date:  2011-07-18       Impact factor: 4.813

6.  High efficiency coronary MR angiography with nonrigid cardiac motion correction.

Authors:  Jianing Pang; Yuhua Chen; Zhaoyang Fan; Christopher Nguyen; Qi Yang; Yibin Xie; Debiao Li
Journal:  Magn Reson Med       Date:  2016-07-25       Impact factor: 4.668

7.  Three-dimensional cine MRI in free-breathing infants and children with congenital heart disease.

Authors:  Achim Seeger; Michael C Fenchel; Gerald F Greil; Petros Martirosian; Ulrich Kramer; Christiane Bretschneider; Joerg Doering; Claus D Claussen; Ludger Sieverding; Stephan Miller
Journal:  Pediatr Radiol       Date:  2009-10-02

8.  Cardiac gating calibration by the Septal Scout for magnetic resonance coronary angiography.

Authors:  Garry Liu; Graham A Wright
Journal:  J Cardiovasc Magn Reson       Date:  2014-01-24       Impact factor: 5.364

9.  Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study.

Authors:  Fabian Kording; Jin Yamamura; Gunnar Lund; Friedrich Ueberle; Caroline Jung; Gerhard Adam; Bjoern Philip Schoennagel
Journal:  Magn Reson Med Sci       Date:  2016-03-21       Impact factor: 2.471

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.