Microelectrodes are among the most accurate and reliable monitoring devices for measuring the dynamics of biofilm processes. This paper describes a novel needle-type microelectrode array (MEA) for simultaneous in situ measurements of dissolved oxygen (DO) and oxidation reduction potential (ORP) fabricated using microelectromechanical systems (MEMS) technologies. The MEA exhibits fast response times for both DO and ORP measurements and shows a substantial increase in DO sensitivity. To demonstrate the versatility of the new sensor, it was applied to the measurement of DO and ORP microprofiles in a multispecies biofilm. This work demonstrates that the MEA is able to monitor local concentration changes with a high spatial resolution and provide the versatility of the microelectrode technique needed for biofilm studies as well as the capability for repetitive measurements. In addition, the use of MEMS technologies and batch fabrication approaches enables integration, high consistency, high yields, and mass production. With further development, it may be possible to add additional sensors to the MEA (e.g., pH, phosphate) and integrate them with a reference electrode.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18075099     DOI: 10.1021/es070969o

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  7 in total

1.  Biofilm thickness measurement using an ultrasound method in a liquid phase.

Authors:  R Maurício; C J Dias; N Jubilado; F Santana
Journal:  Environ Monit Assess       Date:  2013-03-15       Impact factor: 2.513

2.  The reliability of clinical dynamic monitoring of redox status using a new redox potential (ORP) determination method.

Authors:  Lizhu Zhi; Juan Liang; Xinlei Hu; Jun Xu; Chaoheng Yu; Huawei Shao; Xuanliang Pan; Chunmao Han
Journal:  Redox Rep       Date:  2013-03-28       Impact factor: 4.412

3.  Microbiosensor for the detection of acetate in electrode-respiring biofilms.

Authors:  Erhan Atci; Jerome T Babauta; Sujala T Sultana; Haluk Beyenal
Journal:  Biosens Bioelectron       Date:  2016-03-15       Impact factor: 10.618

Review 4.  Material properties of biofilms-a review of methods for understanding permeability and mechanics.

Authors:  Nicole Billings; Alona Birjiniuk; Tahoura S Samad; Patrick S Doyle; Katharina Ribbeck
Journal:  Rep Prog Phys       Date:  2015-02-26

5.  CO2 production as an indicator of biofilm metabolism.

Authors:  Otini Kroukamp; Gideon M Wolfaardt
Journal:  Appl Environ Microbiol       Date:  2009-04-03       Impact factor: 4.792

Review 6.  Microneedles for drug and vaccine delivery.

Authors:  Yeu-Chun Kim; Jung-Hwan Park; Mark R Prausnitz
Journal:  Adv Drug Deliv Rev       Date:  2012-05-01       Impact factor: 15.470

7.  A Minimally Invasive Microsensor Specially Designed for Simultaneous Dissolved Oxygen and pH Biofilm Profiling.

Authors:  Xavier Guimerà; Ana Moya; Antonio David Dorado; Xavi Illa; Rosa Villa; David Gabriel; Xavier Gamisans; Gemma Gabriel
Journal:  Sensors (Basel)       Date:  2019-11-01       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.