Literature DB >> 18066561

Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup.

Dragos Popescu1, X Gallart, S Garcia, G Bori, X Tomas, J Riba.   

Abstract

Alumina ceramic-on-ceramic total hip arthroplasty (THA) has been widely used due to its advantages such as low wear, scratch resistance, wettable surface and relatively low biological reactivity of the wear particles. Nevertheless, this material in THA still persists to be one of the major concerns about the risk of fracture, due to its brittleness. Many authors have reported a fracture of the ceramic head but few reported a fracture of the ceramic acetabular insert. In order to reduce the rigidity of the ceramic-on-ceramic coupling and prevent an impingement between the rim of the ceramic liner and the metal neck of the femoral stem, a modular acetabular component with a sandwich insertion (alumina/polyethylene/titanium) was proposed. We report the fracture of the ceramic acetabular liner of such a ceramic sandwich cup due to a slightly retroverted position of the cup that causes an impingement between the femoral stem and the rim of the insert. The fracture occurred 3 years after the operation without trauma. At revision the entire cup was replaced using a polyethylene liner without inner ceramic liner.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18066561     DOI: 10.1007/s00402-007-0536-z

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  10 in total

1.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

2.  Experience with sandwich liner and its high rate of failure.

Authors:  John Junghun Shin; Ji-Soo Shin; Jae-Hyun Kim; Sung Kwan Hwang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-07-16

3.  High rate of ceramic sandwich liner fracture.

Authors:  Ronny Lopes; Jean M Philippeau; Norbert Passuti; François Gouin
Journal:  Clin Orthop Relat Res       Date:  2012-03-02       Impact factor: 4.176

4.  Imaging of ceramic liner fractures in total hip arthroplasty: the value of CT.

Authors:  Yoshimi Endo; Lisa Renner; Tom Schmidt-Braekling; Douglas N Mintz; Friedrich Boettner
Journal:  Skeletal Radiol       Date:  2015-03-07       Impact factor: 2.199

Review 5.  [The problem of fractures of ceramic heads. What should be done?].

Authors:  H R Dürr
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

6.  Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.

Authors:  Ryan M Baxter; Daniel W Macdonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

7.  Highly Cross-linked Polyethylene Liner Dissociation from a Cement-less Modular Acetabular Shell: Two Case Reports.

Authors:  Shunsuke Kawano; Motoki Sonohata; Masaru Kitajima; Masaaki Mawatari
Journal:  Open Orthop J       Date:  2016-12-26

Review 8.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

9.  Fracture of ceramic liner and head in a total hip arthroplasty with a sandwich type cup.

Authors:  Diego Reátegui; Sebastián García; Guillem Bori; Xavier Gallart
Journal:  Case Rep Orthop       Date:  2013-04-18

10.  Mid term results of total hip arthroplasty using polyethylene-ceramic composite (Sandwich) liner.

Authors:  Tao Wang; Jun-Ying Sun; Guo-Chun Zha; Sheng-Jie Dong; Xi-Jiang Zhao
Journal:  Indian J Orthop       Date:  2016 Jan-Feb       Impact factor: 1.251