Literature DB >> 18059434

Improving PET receptor binding estimates from Logan plots using principal component analysis.

Aniket Joshi1, Jeffrey A Fessler, Robert A Koeppe.   

Abstract

This work reports a principal component analysis (PCA)-based approach for reducing bias in distribution volume ratio (DVR) estimates from Logan plots in positron emission tomography (PET). Comparison has been made of all existing bias-removal methods with the proposed PCA method, for both single-estimate PET studies and intervention studies where pre- and post-intervention estimates are made. Bias in Logan-based DVR estimates is because of the noise in the PET time-activity curves (TACs) that propagates as correlated errors in dependent and independent variables of the Logan equation. Intervention studies show this same bias but also higher variance in DVR estimates. In this work, noise in the TACs was reduced by fitting the curves to a low-dimension PCA-based linear model, leading to reduced bias and variance in DVR. For validating the approach, TACs with realistic noise were simulated for a 11C-labeled tracer with carfentanil (CFN)-like kinetics for both single-measurement and intervention studies. Principal component analysis and existing methods were applied to the simulated data and their performance was compared by statistical analysis. The results indicated that existing methods either removed only part of the bias or reduced bias at the expense of precision. The proposed method removed approximately 90% of the bias while also improving precision in both single- and dual-measurement simulations. After validation of the proposed method in simulations, PCA, along with the existing methods, was applied to human [11C]CFN data acquired for both single estimation of DVR and dual-estimation intervention studies. Similar results were observed in human scans as were seen in the simulation studies.

Entities:  

Mesh:

Year:  2007        PMID: 18059434      PMCID: PMC2910513          DOI: 10.1038/sj.jcbfm.9600584

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  15 in total

1.  Effects of statistical noise on graphic analysis of PET neuroreceptor studies.

Authors:  M Slifstein; M Laruelle
Journal:  J Nucl Med       Date:  2000-12       Impact factor: 10.057

2.  Modified regression model for the Logan plot.

Authors:  József Varga; Zsolt Szabo
Journal:  J Cereb Blood Flow Metab       Date:  2002-02       Impact factor: 6.200

3.  Fast formation of statistically reliable FDG parametric images based on clustering and principal components.

Authors:  Y Kimura; M Senda; N M Alpert
Journal:  Phys Med Biol       Date:  2002-02-07       Impact factor: 3.609

4.  Estimation of kinetic parameters in graphical analysis of PET imaging data.

Authors:  R Todd Ogden
Journal:  Stat Med       Date:  2003-11-30       Impact factor: 2.373

5.  Strategies to improve neuroreceptor parameter estimation by linear regression analysis.

Authors:  Masanori Ichise; Hiroshi Toyama; Robert B Innis; Richard E Carson
Journal:  J Cereb Blood Flow Metab       Date:  2002-10       Impact factor: 6.200

6.  A new application of pre-normalized principal component analysis for improvement of image quality and clinical diagnosis in human brain PET studies--clinical brain studies using [11C]-GR205171, [11C]-L-deuterium-deprenyl, [11C]-5-Hydroxy-L-Tryptophan, [11C]-L-DOPA and Pittsburgh Compound-B.

Authors:  Pasha Razifar; Jan Axelsson; Harald Schneider; Bengt Långström; Ewert Bengtsson; Mats Bergström
Journal:  Neuroimage       Date:  2006-08-24       Impact factor: 6.556

7.  An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation.

Authors:  D Feng; S C Huang; Z Z Wang; D Ho
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

8.  The use of principal components in the quantitative analysis of gamma camera dynamic studies.

Authors:  D C Barber
Journal:  Phys Med Biol       Date:  1980-03       Impact factor: 3.609

9.  A strategy for removing the bias in the graphical analysis method.

Authors:  J Logan; J S Fowler; N D Volkow; Y S Ding; G J Wang; D L Alexoff
Journal:  J Cereb Blood Flow Metab       Date:  2001-03       Impact factor: 6.200

10.  Anatomic standardization: linear scaling and nonlinear warping of functional brain images.

Authors:  S Minoshima; R A Koeppe; K A Frey; D E Kuhl
Journal:  J Nucl Med       Date:  1994-09       Impact factor: 10.057

View more
  16 in total

1.  The use of alternative forms of graphical analysis to balance bias and precision in PET images.

Authors:  Jean Logan; David Alexoff; Joanna S Fowler
Journal:  J Cereb Blood Flow Metab       Date:  2010-09-01       Impact factor: 6.200

2.  Pain imaging in the emerging era of molecular medicine.

Authors:  Christian S Stohler; Jon-Kar Zubieta
Journal:  Methods Mol Biol       Date:  2010

3.  Comparative assessment of parametric neuroreceptor mapping approaches based on the simplified reference tissue model using [¹¹C]ABP688 PET.

Authors:  Seongho Seo; Su J Kim; Yu K Kim; Jee-Young Lee; Jae M Jeong; Dong S Lee; Jae S Lee
Journal:  J Cereb Blood Flow Metab       Date:  2015-08-05       Impact factor: 6.200

4.  Reference region approaches in PET: a comparative study on multiple radioligands.

Authors:  Francesca Zanderigo; R Todd Ogden; Ramin V Parsey
Journal:  J Cereb Blood Flow Metab       Date:  2013-02-20       Impact factor: 6.200

5.  Empirical Bayesian estimation in graphical analysis: a voxel-based approach for the determination of the volume of distribution in PET studies.

Authors:  Francesca Zanderigo; R Todd Ogden; Alessandra Bertoldo; Claudio Cobelli; J John Mann; Ramin V Parsey
Journal:  Nucl Med Biol       Date:  2010-04-07       Impact factor: 2.408

Review 6.  Recent advances in parametric neuroreceptor mapping with dynamic PET: basic concepts and graphical analyses.

Authors:  Seongho Seo; Su Jin Kim; Dong Soo Lee; Jae Sung Lee
Journal:  Neurosci Bull       Date:  2014-09-28       Impact factor: 5.203

7.  A linear model for estimation of neurotransmitter response profiles from dynamic PET data.

Authors:  Marc D Normandin; Wynne K Schiffer; Evan D Morris
Journal:  Neuroimage       Date:  2011-07-13       Impact factor: 6.556

8.  Multi-graphical analysis of dynamic PET.

Authors:  Yun Zhou; Weiguo Ye; James R Brasić; Dean F Wong
Journal:  Neuroimage       Date:  2009-11-17       Impact factor: 6.556

9.  Multiple linear analysis methods for the quantification of irreversibly binding radiotracers.

Authors:  Su Jin Kim; Jae Sung Lee; Yu Kyeong Kim; James Frost; Gary Wand; Mary E McCaul; Dong Soo Lee
Journal:  J Cereb Blood Flow Metab       Date:  2008-07-16       Impact factor: 6.200

10.  Smoothing dynamic positron emission tomography time courses using functional principal components.

Authors:  Ci-Ren Jiang; John A D Aston; Jane-Ling Wang
Journal:  Neuroimage       Date:  2009-04-01       Impact factor: 6.556

View more