Literature DB >> 18215932

An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation.

D Feng1, S C Huang, Z Z Wang, D Ho.   

Abstract

An unbiased algorithm of generalized linear least squares (GLLS) for parameter estimation of nonuniformly sampled biomedical systems is proposed. The basic theory and detailed derivation of the algorithm are given. This algorithm removes the initial values required and computational burden of nonlinear least regression and achieves a comparable estimation quality in terms of the estimates' bias and standard deviation. Therefore, this algorithm is particular useful in image-wide (pixel-by-pixel based) parameter estimation, e.g., to generate parametric images from tracer dynamic studies with positron emission tomography. An example is presented to demonstrate the performance of this new technique. This algorithm is also generally applicable to other continuous system parameter estimation.

Year:  1996        PMID: 18215932     DOI: 10.1109/42.511754

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  14 in total

1.  Modified regression model for the Logan plot.

Authors:  József Varga; Zsolt Szabo
Journal:  J Cereb Blood Flow Metab       Date:  2002-02       Impact factor: 6.200

2.  Improving PET receptor binding estimates from Logan plots using principal component analysis.

Authors:  Aniket Joshi; Jeffrey A Fessler; Robert A Koeppe
Journal:  J Cereb Blood Flow Metab       Date:  2007-12-05       Impact factor: 6.200

Review 3.  Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT.

Authors:  H Iida; S Eberl
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

4.  Empirical Bayesian estimation in graphical analysis: a voxel-based approach for the determination of the volume of distribution in PET studies.

Authors:  Francesca Zanderigo; R Todd Ogden; Alessandra Bertoldo; Claudio Cobelli; J John Mann; Ramin V Parsey
Journal:  Nucl Med Biol       Date:  2010-04-07       Impact factor: 2.408

5.  A method for generating image-derived input function in quantitative 18F-FDG PET study based on the monotonicity of the input and output function curve.

Authors:  Shan Zhou; Kewei Chen; Eric M Reiman; De-min Li; Baoci Shan
Journal:  Nucl Med Commun       Date:  2012-04       Impact factor: 1.690

Review 6.  Recent advances in parametric neuroreceptor mapping with dynamic PET: basic concepts and graphical analyses.

Authors:  Seongho Seo; Su Jin Kim; Dong Soo Lee; Jae Sung Lee
Journal:  Neurosci Bull       Date:  2014-09-28       Impact factor: 5.203

7.  Simplified estimation of binding parameters based on image-derived reference tissue models for dopamine transporter bindings in non-human primates using [18F]FE-PE2I and PET.

Authors:  Ikuo Odano; Andrea Varrone; Tetsuo Hosoya; Kazuya Sakaguchi; Balázs Gulyás; Parasuraman Padmanabhan; Krishna Kanta Ghosh; Chang-Tong Yang; Ilonka Guenther; Zhimin Wang; Raymond Serrano; Nevil Ghislain Chimon; Christer Halldin
Journal:  Am J Nucl Med Mol Imaging       Date:  2017-12-20

8.  Non-invasive assessment of distribution volume ratios and binding potential: tissue heterogeneity and interindividually averaged time-activity curves.

Authors:  M Reimold; W Mueller-Schauenburg; G A Becker; G Reischl; B M Dohmen; R Bares
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-12-19       Impact factor: 9.236

9.  Multiple linear analysis methods for the quantification of irreversibly binding radiotracers.

Authors:  Su Jin Kim; Jae Sung Lee; Yu Kyeong Kim; James Frost; Gary Wand; Mary E McCaul; Dong Soo Lee
Journal:  J Cereb Blood Flow Metab       Date:  2008-07-16       Impact factor: 6.200

10.  FDG-PET parametric imaging by total variation minimization.

Authors:  Hongbin Guo; Rosemary A Renaut; Kewei Chen; Eric Reiman
Journal:  Comput Med Imaging Graph       Date:  2009-03-03       Impact factor: 4.790

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.