Literature DB >> 18056513

Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty.

Cale A Jacobs1, Christian P Christensen, A Seth Greenwald, Harry McKellop.   

Abstract

Aseptic loosening secondary to wear-debris-induced osteolysis has been identified as the leading cause of late failure of total hip arthroplasty. Highly cross-linked polyethylene acetabular liners were developed as one approach to reducing this wear. Preclinical laboratory wear testing showed a number of cross-linked polyethylenes to have dramatically less wear than the polyethylene that had been in use for several decades. After the initial bedding-in phase (one to two years), the percent reductions in the wear rate, as indicated by the amount of penetration of the head into the socket evident on serial radiographs, have been comparable with what was predicted from preclinical hip-simulator testing of the highly cross-linked polyethylenes. To our knowledge, there have been no reports of clinically relevant osteolysis that was clearly attributable to wear of a highly cross-linked polyethylene acetabular liner. However, the clinical performance of these materials should be closely monitored with long-term follow-up.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18056513     DOI: 10.2106/JBJS.G.00043

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  28 in total

1.  Relationship between the pelvic osteolytic volume on computed tomography and clinical outcome in patients with cementless acetabular components.

Authors:  Ho Hyun Yun; Won Yong Shon; Suk Joo Hong; Jung-Ro Yoon; Jae-Hyuk Yang
Journal:  Int Orthop       Date:  2010-10-07       Impact factor: 3.075

2.  Causes of failure of ceramic-on-ceramic and metal-on-metal hip arthroplasties.

Authors:  Manny Porat; Javad Parvizi; Peter F Sharkey; Keith R Berend; Adolph V Lombardi; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Edward Ebramzadeh; Harry McKellop
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  Continued improved wear with an annealed highly cross-linked polyethylene.

Authors:  William N Capello; James A D'Antonio; Rama Ramakrishnan; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2010-09-16       Impact factor: 4.176

5.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

6.  Wear is reduced in THA performed with highly cross-linked polyethylene.

Authors:  Burak Beksaç; Antonio Salas; Alejandro González Della Valle; Eduardo A Salvati
Journal:  Clin Orthop Relat Res       Date:  2008-12-12       Impact factor: 4.176

Review 7.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

8.  What are the options for better outcomes of total hip arthroplasty?

Authors:  Shin-Yoon Kim
Journal:  Clin Orthop Surg       Date:  2010-11-05

9.  Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem.

Authors:  Robert M Urban; Deborah J Hall; Craig Della Valle; Markus A Wimmer; Joshua J Jacobs; Jorge O Galante
Journal:  J Bone Joint Surg Am       Date:  2012-10-17       Impact factor: 5.284

10.  UHMWPE for arthroplasty: past or future?

Authors:  Elena Maria Brach Del Prever; Alessandro Bistolfi; Pierangiola Bracco; Luigi Costa
Journal:  J Orthop Traumatol       Date:  2008-12-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.