Literature DB >> 1805395

Experience with a transnasally fixed endoprosthesis for treating esophageal anastomotic leakage.

M Brückner1, H Grimm, V C Nam, N Soehendra.   

Abstract

Eight patients suffering from leakage around the esophagus were treated with a transnasally fixed Celestin tube. All of the subjects had exhibited an anastomotic dehiscence after having undergone esophageal resection, cardia resection or total gastrectomy. Following treatment, in all cases the anastomoses healed quickly with no complications.

Entities:  

Mesh:

Year:  1991        PMID: 1805395     DOI: 10.1007/BF02653260

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  12 in total

1.  Safety of EEA staplers for anastomosis between upper esophagus and the gastric tube.

Authors:  K Sugimachi; S Ohno; S Maekawa; M Mori; H Kuwano; H Ueo
Journal:  J Surg Oncol       Date:  1990-01       Impact factor: 3.454

2.  Limitations and dangers of gastrografin swallow after esophageal and upper gastric operations.

Authors:  S T Fan; W Y Lau; W C Yip; G P Poon; C Yeung; K K Wong
Journal:  Am J Surg       Date:  1988-03       Impact factor: 2.565

3.  'Noninvasive' treatment of esophagogastric anastomotic leakage.

Authors:  J D Papadimitriou; G Exarchakos; J Condis
Journal:  Arch Surg       Date:  1988-01

4.  Four hundred esophageal anastomoses with a stapler.

Authors:  F Fekete; B Gayet; S Place; J Biagini
Journal:  Int Surg       Date:  1989 Apr-Jun

5.  Experience with the EEA stapler for esophagojejunostomy.

Authors:  H Habu; F Kando; N Saito; Y Sato; K Takeshita; M Sunagawa; M Endo
Journal:  Int Surg       Date:  1989 Apr-Jun

6.  Transnasal fixation of the esophageal prosthesis.

Authors:  M Brückner; H Grimm; V C Nam; N Soehendra
Journal:  Endoscopy       Date:  1988-11       Impact factor: 10.093

7.  [Treatment of suture insufficiency--preliminary therapy, definitive therapy, indications].

Authors:  R Pichlmayr; H J Meyer
Journal:  Langenbecks Arch Chir       Date:  1982

8.  Esophagogastric anastomosis performed with a stapler: the occurrence of leakage and stricture.

Authors:  J Wong; H Cheung; R Lui; Y W Fan; A Smith; K F Siu
Journal:  Surgery       Date:  1987-04       Impact factor: 3.982

9.  Some clinical and technical aspects of circular stapled anastomoses of rectum and oesophagus.

Authors:  G H Dickson
Journal:  Ann R Coll Surg Engl       Date:  1989-01       Impact factor: 1.891

10.  Esophagovisceral anastomotic leak. A prospective statistical study of predisposing factors.

Authors:  A Peracchia; R Bardini; A Ruol; M Asolati; D Scibetta
Journal:  J Thorac Cardiovasc Surg       Date:  1988-04       Impact factor: 5.209

View more
  4 in total

1.  Endoscopic vacuum sponge therapy for esophageal defects.

Authors:  Gunnar Loske; Tobias Schorsch; Christian Müller
Journal:  Surg Endosc       Date:  2010-03-24       Impact factor: 4.584

2.  A double-layered (comvi) self-expandable metal stent for malignant gastroduodenal obstruction: a prospective multicenter study.

Authors:  Yong Wuk Kim; Cheol Woong Choi; Dae Hwan Kang; Hyung Wook Kim; Chung Uk Chung; Dong Uk Kim; Su Bum Park; Kee Tae Park; Suk Kim; Eul Jo Jeung; Yong Mok Bae
Journal:  Dig Dis Sci       Date:  2011-01-25       Impact factor: 3.199

3.  Endoscopic management of inveterate esophageal perforations and leaks.

Authors:  A Segalin; L Bonavina; M Lazzerini; F De Ruberto; C Faranda; A Peracchia
Journal:  Surg Endosc       Date:  1996-09       Impact factor: 4.584

4.  Successful closure of spontaneous esophageal rupture (Boerhaave's syndrome) by endoscopic ligation with snare loops.

Authors:  Jun Kuwabara; Yuji Watanabe; You Kojima; Naoyuki Higaki; Yoshiou Ikeda; Kouichi Sato; Motohira Yoshida; Yuji Yamamoto; Satoshi Kikuchi
Journal:  Springerplus       Date:  2016-06-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.