Maximizing the laboratory setting for testing devices and understanding statistical output in pulse oximetry.

Paul B Batchelder1, Dena M Raley.   

Abstract

Maximizing the laboratory setting for testing baseline pulse oximetry accuracy in an arterial desaturation study requires a study design that considers management of several aspects in the physiology of the test subject, special attention to the device under test, and great care in the preanalytical (sample handling) and analytical (Co-oximeter) phases. Statistics used to describe the resulting SpO2 performance include Precision (size of the data cloud), Bias (offset of the data cloud), and A(rms) (accuracy root mean square), which combines the size and offset of the data cloud in one number. The A(rms) is the primary statistic required by regulatory organizations to describe general performance over the entire saturation range. It does not describe any one point, but is a compilation of all points over the range tested. Most pulse oximeters in use today specify an A(rms) of 2%. To meet this specification, two-thirds of the readings will be within 2% of the Co-oximeter reference; however, some individual readings can be as inaccurate as 6% or more. The A(rms) statistic does not have the capacity to represent all pulse oximeter behavior. Saturation pop-ups, drop-downs, frozen readings, and periods of no reading are not portrayed by the A(rms). The next steps in the advancement of regulatory validation testing would be to develop standards that include an expanded analysis of pulse oximeter performance by assessment of pop-ups, dropouts, frozen readings, and periods of no reading through assessment of sensitivity/specificity and possibly a "Performance Index" similar to the approach taken by Barker.

Mesh:

Substances:

Year:  2007        PMID: 18048904     DOI: 10.1213/01.ane.0000268495.35207.ab

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  11 in total

1.  The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia.

Authors:  Elizabeth E Foglia; Robin K Whyte; Aasma Chaudhary; Antonio Mott; Jodi Chen; Kathleen J Propert; Barbara Schmidt
Journal:  J Pediatr       Date:  2016-12-09       Impact factor: 4.406

2.  Development of Low-Cost and Portable Pulse Oximeter Device with Improved Accuracy and Accessibility.

Authors:  Hundessa Daba Nemomssa; Hakkins Raj
Journal:  Med Devices (Auckl)       Date:  2022-05-05

3.  Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO2-saturation sensor.

Authors:  Jarkko Harju; Antti Vehkaoja; Ville Lindroos; Pekka Kumpulainen; Sasu Liuhanen; Arvi Yli-Hankala; Niku Oksala
Journal:  J Clin Monit Comput       Date:  2016-10-17       Impact factor: 2.502

4.  Calibration-free pulse oximetry based on two wavelengths in the infrared - a preliminary study.

Authors:  Meir Nitzan; Salman Noach; Elias Tobal; Yair Adar; Yaacov Miller; Eran Shalom; Shlomo Engelberg
Journal:  Sensors (Basel)       Date:  2014-04-23       Impact factor: 3.576

5.  Proof of concept non-invasive estimation of peripheral venous oxygen saturation.

Authors:  Musabbir Khan; Chris G Pretty; Alexander C Amies; Joel Balmer; Houda E Banna; Geoffrey M Shaw; J Geoffrey Chase
Journal:  Biomed Eng Online       Date:  2017-05-19       Impact factor: 2.819

6.  Racial discrepancy in pulse oximeter accuracy in preterm infants.

Authors:  Zachary Vesoulis; Anna Tims; Hafsa Lodhi; Natasha Lalos; Halana Whitehead
Journal:  J Perinatol       Date:  2021-10-12       Impact factor: 3.225

7.  Evaluation of a New Smartphone Powered Low-cost Pulse Oximeter Device.

Authors:  Hundessa Daba Nemomssa; Hakkins Raj
Journal:  Ethiop J Health Sci       Date:  2022-07

8.  Smartphone camera oximetry in an induced hypoxemia study.

Authors:  Jason S Hoffman; Varun K Viswanath; Caiwei Tian; Xinyi Ding; Matthew J Thompson; Eric C Larson; Shwetak N Patel; Edward J Wang
Journal:  NPJ Digit Med       Date:  2022-09-19

Review 9.  Pulse oximetry: fundamentals and technology update.

Authors:  Meir Nitzan; Ayal Romem; Robert Koppel
Journal:  Med Devices (Auckl)       Date:  2014-07-08

10.  Evaluation of a Novel Ear Pulse Oximeter: Towards Automated Oxygen Titration in Eyeglass Frames.

Authors:  Fabian Braun; Christophe Verjus; Josep Solà; Marcus Marienfeld; Manuela Funke-Chambour; Jens Krauss; Thomas Geiser; Sabina A Guler
Journal:  Sensors (Basel)       Date:  2020-06-10       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.