Literature DB >> 18044547

Intra-operative 3D guidance in prostate brachytherapy using a non-isocentric C-arm.

A Jain1, A Deguet, I Iordachita, G Chintalapani, J Blevins, Y Le, E Armour, C Burdette, D Song, G Fichtinger.   

Abstract

Intra-operative guidance in Transrectal Ultrasound (TRUS) guided prostate brachytherapy requires localization of inserted radioactive seeds relative to the prostate. Seeds were reconstructed using a typical C-arm, and exported to a commercial brachytherapy system for dosimetry analysis. Technical obstacles for 3D reconstruction on a non-isocentric C-arm included pose-dependent C-arm calibration; distortion correction; pose estimation of C-arm images; seed reconstruction; and C-arm to TRUS registration. In precision-machined hard phantoms with 40-100 seeds, we correctly reconstructed 99.8% seeds with a mean 3D accuracy of 0.68 mm. In soft tissue phantoms with 45-87 seeds and clinically realistic 15 degrees C-arm motion, we correctly reconstructed 100% seeds with an accuracy of 1.3 mm. The reconstructed 3D seed positions were then registered to the prostate segmented from TRUS. In a Phase-1 clinical trial, so far on 4 patients with 66-84 seeds, we achieved intra-operative monitoring of seed distribution and dosimetry. We optimized the 100% prescribed iso-dose contour by inserting an average of 3.75 additional seeds, making intra-operative dosimetry possible on a typical C-arm, at negligible additional cost to the existing clinical installation.

Entities:  

Mesh:

Year:  2007        PMID: 18044547     DOI: 10.1007/978-3-540-75759-7_2

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  8 in total

1.  C-arm rotation encoding with accelerometers.

Authors:  Victor Grzeda; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-04-10       Impact factor: 2.924

2.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

3.  Robotic assistance for ultrasound-guided prostate brachytherapy.

Authors:  Gabor Fichtinger; Jonathan P Fiene; Christopher W Kennedy; Gernot Kronreif; Iulian Iordachita; Danny Y Song; Everette C Burdette; Peter Kazanzides
Journal:  Med Image Anal       Date:  2008-06-18       Impact factor: 8.545

4.  A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

Authors:  Shahram Amiri; David R Wilson; Bassam A Masri; Carolyn Anglin
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-10       Impact factor: 2.924

5.  Automatic segmentation of radiographic fiducial and seeds from X-ray images in prostate brachytherapy.

Authors:  Nathanael Kuo; Anton Deguet; Danny Y Song; Everette C Burdette; Jerry L Prince; Junghoon Lee
Journal:  Med Eng Phys       Date:  2011-07-29       Impact factor: 2.242

6.  Intra-operative 3D guidance and edema detection in prostate brachytherapy using a non-isocentric C-arm.

Authors:  A Jain; A Deguet; I Iordachita; G Chintalapani; S Vikal; J Blevins; Y Le; E Armour; C Burdette; D Song; G Fichtinger
Journal:  Med Image Anal       Date:  2010-08-14       Impact factor: 8.545

7.  Intra-operative Localization of Brachytherapy Implants Using Intensity-based Registration.

Authors:  Z Karimaghaloo; P Abolmaesumi; N Ahmidi; T K Chen; D G Gobbi; G Fichtinger
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01

8.  Surgical and Interventional Robotics: Part II: Surgical CAD-CAM Systems.

Authors:  Gabor Fichtinger; Peter Kazanzides; Allison M Okamura; Gregory D Hager; Louis L Whitcomb; Russell H Taylor
Journal:  IEEE Robot Autom Mag       Date:  2008-09-01       Impact factor: 5.143

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.