Color Doppler imaging of cardiac catheters using vibrating motors.

Kalyan E Reddy1, Edward D Light, Danny J Rivera, Joseph A Kisslo, Stephen W Smith.   

Abstract

A miniature motor rotating at 11,000 rpm was attached onto the proximal end of cardiac electrophysiological (EP) catheters in order to produce vibrations at the tip that were then visualized by color Doppler on ultrasound scanners. The catheter tip was imaged within a vascular graft submerged in a water tank using the Volumetrics Medical Imaging 3D scanner, the Siemens Sonoline Antares 2D scanner and the Philips ie33 3D ultrasound scanner with TEE probe. The vibrating catheter tip was visualized in each case, although results varied with the color Doppler properties of the individual scanner.

Entities:  

Mesh:

Year:  2008        PMID: 19514134      PMCID: PMC2804844          DOI: 10.1177/016173460803000408

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  6 in total

1.  Guidance of cardiac pacemaker leads using real time 3D ultrasound: feasibility studies.

Authors:  Stephen W Smith; Rebecca C Booi; Edward D Light; Christine L Merdes; Patrick D Wolf
Journal:  Ultrason Imaging       Date:  2002-04       Impact factor: 1.578

2.  Piezoelectric vibrating needle and catheter for enhancing ultrasound-guided peripheral nerve blocks.

Authors:  Stephen M Klein; Matthew P Fronheiser; John Reach; Karen C Nielsen; Stephen W Smith
Journal:  Anesth Analg       Date:  2007-12       Impact factor: 5.108

3.  Analysis of a vibrating interventional device to improve 3-D colormark tracking.

Authors:  Matthew P Fronheiser; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-08       Impact factor: 2.725

4.  Vibrating interventional device detection using real-time 3-D color Doppler.

Authors:  Matthew P Fronheiser; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

5.  Localization of needle tip with color doppler during pericardiocentesis: In vitro validation and initial clinical application.

Authors:  G Armstrong; L Cardon; D Vilkomerson; D Lipson; J Wong; L L Rodriguez; J D Thomas; B P Griffin
Journal:  J Am Soc Echocardiogr       Date:  2001-01       Impact factor: 5.251

6.  Real-time 3D color flow Doppler for guidance of vibrating interventional devices.

Authors:  Matthew P Fronheiser; Patrick D Wolf; Salim F Idriss; Rendon C Nelson; Warren Lee; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2004-07       Impact factor: 1.578

  6 in total
  3 in total

1.  Real-Time Visualization of an Acoustically Active Injection Catheter With Ultrasound Imaging: Algorithm and In Vivo Validation in a Swine Model.

Authors:  Viksit Kumar; Minako Katayama; Rachael Peavler; Azra Alizad; Marek Belohlavek; Mostafa Fatemi
Journal:  IEEE Trans Biomed Eng       Date:  2019-03-01       Impact factor: 4.538

Review 2.  Development of technologies for placement of perineural catheters.

Authors:  Hesham Elsharkawy; Ankit Maheshwari; Ehab Farag; Edward R Mariano; Richard W Rosenquist
Journal:  J Anesth       Date:  2015-09-14       Impact factor: 2.078

3.  3-D ultrasound-guided robotic needle steering in biological tissue.

Authors:  Troy K Adebar; Ashley E Fletcher; Allison M Okamura
Journal:  IEEE Trans Biomed Eng       Date:  2014-07-01       Impact factor: 4.538

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.