Accuracy of q-space related parameters in MRI: simulations and phantom measurements.

Jimmy Lätt1, Markus Nilsson, Carin Malmborg, Hannah Rosquist, Ronnie Wirestam, Freddy Ståhlberg, Daniel Topgaard, Sara Brockstedt.   

Abstract

The accuracy of q-space measurements was evaluated at a 3.0-T clinical magnetic resonance imaging (MRI) scanner, as compared with a 4.7-T nuclear magnetic resonance (NMR) spectrometer. Measurements were performed using a stimulated-echo pulse-sequence on n-decane as well as on polyethylene glycol (PEG) mixed with different concentrations of water, in order to obtain bi-exponential signal decay curves. The diffusion coefficients as well as the modelled diffusional kurtosis K(fit) were obtained from the signal decay curve, while the full-width at half-maximum (FWHM) and the diffusional kurtosis K were obtained from the displacement distribution. Simulations of restricted diffusion, under conditions similar to those obtainable with a clinical MRI scanner, were carried out assuming various degrees of violation of the short gradient pulse (SGP) condition and of the long diffusion time limit. The results indicated that an MRI system can not be used for quantification of structural sizes less than about 10 microm by means of FWHM since the parameter underestimates the confinements due to violation of the SGP condition. However, FWHM can still be used as an important contrast parameter. The obtained kurtosis values were lower than expected from theory and the results showed that care must be taken when interpreting a kurtosis estimate deviating from zero.

Entities:  

Mesh:

Year:  2007        PMID: 18041259     DOI: 10.1109/TMI.2007.907278

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  16 in total

1.  q-space and conventional diffusion imaging of axon and myelin damage in the rat spinal cord after axotomy.

Authors:  Jonathan A D Farrell; Jiangyang Zhang; Melina V Jones; Cynthia A Deboy; Paul N Hoffman; Bennett A Landman; Seth A Smith; Daniel S Reich; Peter A Calabresi; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

2.  Effects of restricted diffusion in a biological phantom: a q-space diffusion MRI study of asparagus stems at a 3T clinical scanner.

Authors:  Jimmy Lätt; Markus Nilsson; Anna Rydhög; Ronnie Wirestam; Freddy Ståhlberg; Sara Brockstedt
Journal:  MAGMA       Date:  2007-10-19       Impact factor: 2.310

3.  Q-space trajectory imaging for multidimensional diffusion MRI of the human brain.

Authors:  Carl-Fredrik Westin; Hans Knutsson; Ofer Pasternak; Filip Szczepankiewicz; Evren Özarslan; Danielle van Westen; Cecilia Mattisson; Mats Bogren; Lauren J O'Donnell; Marek Kubicki; Daniel Topgaard; Markus Nilsson
Journal:  Neuroimage       Date:  2016-02-23       Impact factor: 6.556

4.  Precision and accuracy of diffusion kurtosis estimation and the influence of b-value selection.

Authors:  Andrey Chuhutin; Brian Hansen; Sune Nørhøj Jespersen
Journal:  NMR Biomed       Date:  2017-08-25       Impact factor: 4.044

Review 5.  MRI quantification of non-Gaussian water diffusion by kurtosis analysis.

Authors:  Jens H Jensen; Joseph A Helpern
Journal:  NMR Biomed       Date:  2010-08       Impact factor: 4.044

Review 6.  The role of tissue microstructure and water exchange in biophysical modelling of diffusion in white matter.

Authors:  Markus Nilsson; Danielle van Westen; Freddy Ståhlberg; Pia C Sundgren; Jimmy Lätt
Journal:  MAGMA       Date:  2013-02-27       Impact factor: 2.310

7.  The link between diffusion MRI and tumor heterogeneity: Mapping cell eccentricity and density by diffusional variance decomposition (DIVIDE).

Authors:  Filip Szczepankiewicz; Danielle van Westen; Elisabet Englund; Carl-Fredrik Westin; Freddy Ståhlberg; Jimmy Lätt; Pia C Sundgren; Markus Nilsson
Journal:  Neuroimage       Date:  2016-07-20       Impact factor: 6.556

8.  Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRI.

Authors:  Hua Li; Xiaoyu Jiang; Jingping Xie; John C Gore; Junzhong Xu
Journal:  Magn Reson Med       Date:  2016-06-25       Impact factor: 4.668

9.  Q-space truncation and sampling in diffusion spectrum imaging.

Authors:  Qiyuan Tian; Ariel Rokem; Rebecca D Folkerth; Aapo Nummenmaa; Qiuyun Fan; Brian L Edlow; Jennifer A McNab
Journal:  Magn Reson Med       Date:  2016-01-13       Impact factor: 4.668

10.  Mapping mean axon diameter and axonal volume fraction by MRI using temporal diffusion spectroscopy.

Authors:  Junzhong Xu; Hua Li; Kevin D Harkins; Xiaoyu Jiang; Jingping Xie; Hakmook Kang; Mark D Does; John C Gore
Journal:  Neuroimage       Date:  2014-09-16       Impact factor: 6.556

View more