Literature DB >> 18029025

A simulation study for a surface EMG sensor that detects distinguishable motor unit action potentials.

Jin Lee1, Alexander Adam, Carlo J De Luca.   

Abstract

An advanced volume conductor model was used to simulate the surface-detected motor unit action potentials (MUAPs) due to current sources located at different depths within the muscle tissue of the biceps brachii. Seven different spatial filters were investigated by linear summation of the monopolarly detected surface MUAPs on a square array of nine electrodes. The criterion of the relative energy-of-difference (EOD) between the MUAPs was used to rank spatial filters for their ability to distinguish two motor units located at different depths. Using the same criterion pair wise combinations of spatial filters were ranked for their ability to generate different MUAP shape representations of the same motor unit. In both analyses, the bi-transversal double-differential (BiTDD) configurations and pair wise combinations involving a BiTDD configuration consistently ranked highest. Varying electrode spacing did not change the results in a relevant way. Based on the EOD calculations, a four-channel detection system using all available electrodes of the array is proposed. The implications of using only six electrodes, effectively reducing contact area of the sensor in half, are discussed.

Mesh:

Year:  2007        PMID: 18029025      PMCID: PMC2692496          DOI: 10.1016/j.jneumeth.2007.09.007

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  46 in total

1.  Effect of electrode dimensions on motor unit potentials.

Authors:  N A Dimitrova; G V Dimitrov; V N Chikhman
Journal:  Med Eng Phys       Date:  1999 Jul-Sep       Impact factor: 2.242

2.  A novel approach for precise simulation of the EMG signal detected by surface electrodes.

Authors:  D Farina; R Merletti
Journal:  IEEE Trans Biomed Eng       Date:  2001-06       Impact factor: 4.538

3.  Decomposition of multiunit electromyographic signals.

Authors:  J Fang; G C Agarwal; B T Shahani
Journal:  IEEE Trans Biomed Eng       Date:  1999-06       Impact factor: 4.538

4.  Three-layer volume conductor model and software package for applications in surface electromyography.

Authors:  J H Blok; D F Stegeman; A van Oosterom
Journal:  Ann Biomed Eng       Date:  2002-04       Impact factor: 3.934

5.  Neither high-pass filtering nor mathematical differentiation of the EMG signals can considerably reduce cross-talk.

Authors:  N A Dimitrova; G V Dimitrov; O A Nikitin
Journal:  J Electromyogr Kinesiol       Date:  2002-08       Impact factor: 2.368

6.  Precise and fast calculation of the motor unit potentials detected by a point and rectangular plate electrode.

Authors:  G V Dimitrov; N A Dimitrova
Journal:  Med Eng Phys       Date:  1998-07       Impact factor: 2.242

7.  The active fiber in a volume conductor.

Authors:  R Plonsey
Journal:  IEEE Trans Biomed Eng       Date:  1974-09       Impact factor: 4.538

8.  Volume conduction of motor unit potentials from different human muscles to long distances.

Authors:  A Gydikov; L Gerilovsky; P Gatev; K Kostov
Journal:  Electromyogr Clin Neurophysiol       Date:  1982 Jan-Feb

9.  Automatic decomposition of the clinical electromyogram.

Authors:  K C McGill; K L Cummins; L J Dorfman
Journal:  IEEE Trans Biomed Eng       Date:  1985-07       Impact factor: 4.538

10.  A procedure for decomposing the myoelectric signal into its constituent action potentials--Part II: Execution and test for accuracy.

Authors:  R S LeFever; A P Xenakis; C J De Luca
Journal:  IEEE Trans Biomed Eng       Date:  1982-03       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.