Literature DB >> 10624743

Effect of electrode dimensions on motor unit potentials.

N A Dimitrova1, G V Dimitrov, V N Chikhman.   

Abstract

Different effects of longitudinal and transversal electrode dimensions on nerve or muscle single fibre action potentials detected monopolarly, were reported in the literature. The results were contradictory. We studied motor unit potentials (MUPs) detected at a large distance (typical of surface recording) on the basis of a mathematical model without source simplification. The MUPs were calculated as a single convolution of the first temporal derivative of a realistic intracellular action potential and MU impulse response. The spatial averaging of the MUPs by rectangular plate electrodes was performed through analytical integration of the MU impulse response over the electrode area. The effects of longitudinal dimension of the electrode were stronger than those of a transversal one. The effects were distance dependent. The longitudinal dimension of the electrode influenced the main phases (that reflected the excitation origin and propagation) more than the terminal phases (that reflected the excitation extinction at the muscle fibers' ends). This was due to differences in the character of the potential fields (quadrupole or dipole) during generation of individual MUP phases. It was shown that the relative weight of the individual MUP phases could be stressed or suppressed by a proper choice of electrode dimensions, position and orientation.

Mesh:

Year:  1999        PMID: 10624743     DOI: 10.1016/s1350-4533(99)00069-7

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

Review 1.  Surface electromyogram signal modelling.

Authors:  K C McGill
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

2.  Advances in surface electromyographic signal simulation with analytical and numerical descriptions of the volume conductor.

Authors:  D Farina; L Mesin; S Martina
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

3.  A simulation study for a surface EMG sensor that detects distinguishable motor unit action potentials.

Authors:  Jin Lee; Alexander Adam; Carlo J De Luca
Journal:  J Neurosci Methods       Date:  2007-09-18       Impact factor: 2.390

4.  Analysis of deep brain stimulation electrode characteristics for neural recording.

Authors:  Alexander R Kent; Warren M Grill
Journal:  J Neural Eng       Date:  2014-06-12       Impact factor: 5.379

5.  Specificity of surface EMG recordings for gastrocnemius during upright standing.

Authors:  Taian Martins Vieira; Alberto Botter; Silvia Muceli; Dario Farina
Journal:  Sci Rep       Date:  2017-10-16       Impact factor: 4.379