Literature DB >> 17986265

Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments.

Yoshihiro Ito1, Daisuke Sato, Satoshi Yoneda, Daisuke Ito, Hisatomo Kondo, Shohei Kasugai.   

Abstract

BACKGROUND: Resonance frequency analysis (RFA) is applied to evaluate implant stability, and the clinical relevance of this application is accepted. However, a discrepancy between resonance frequency (RF) and other parameters of implant stability such as implant insertion torque and bone mineral density at the insertion site has been reported. In addition, the relation between RF and histological implant-bone contact has not been well documented.
PURPOSE: To explain this discrepancy and to clarify the relation between RF and histological implant-bone contact, we conducted the present study.
MATERIALS AND METHODS: A hydroxyapatite-coated implant, 4 mm diameter and 10 mm length, was used. We placed the implant in a small plastic box vertically and fixed the implant in the box with small screws at different height positions. An 'Osstell' transducer was mounted on the implant and RF was measured with or without loosening the screws. Twenty-four implants were placed in the tibiae of four mini-pigs. The animals were sacrificed 1, 2 and 4 weeks after the placement, and the RF of each implant was measured. Ground sections were prepared and implant-bone contact was histomophometrically measured.
RESULTS: Loosening the screw at the neck region of the implant remarkably decreased RF compared with the screws of the other regions. Correlation between RF and implant-bone contact, which was measured all around the implant, was not significant (r=0.221, P=0.299). However, the correlation coefficient increased to '0.361' when implant-bone contact was measured at the neck of the implant (P=0.0835), although these two parameters were not statistically correlated.
CONCLUSIONS: Although RF did not correlate with histological implant-bone contact, the present results demonstrated that a connection between the implant and bone at the neck region of the implant affects RF the most effectively, further suggesting the superiority of RFA in the process of implant treatment and the follow-up. The present results could explain the discrepancy between RFA and other parameters of implant stability.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17986265     DOI: 10.1111/j.1600-0501.2007.01419.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  14 in total

1.  Relation between insertion torque and bone-implant contact percentage: an artificial bone study.

Authors:  Cheng Liu; Ming-Tzu Tsai; Heng-Li Huang; Michael Yuan-Chien Chen; Jui-Ting Hsu; Kuo-Chih Su; Chih-Han Chang; Aaron Yu-Jen Wu
Journal:  Clin Oral Investig       Date:  2012-01-10       Impact factor: 3.573

2.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

Review 3.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

4.  A Radiographic and Clinical Comparison of Immediate vs. Early Loading (4 Weeks) of Implants with a New Thermo-Chemically Treated Surface: A Randomized Clinical Trial.

Authors:  Matteo Albertini; Federico Herrero-Climent; Carmen María Díaz-Castro; Jose Nart; Ana Fernández-Palacín; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2021-01-29       Impact factor: 3.390

5.  The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia.

Authors:  In-Phill Park; Seong-Kyun Kim; Shin-Jae Lee; Joo-Hee Lee
Journal:  J Adv Prosthodont       Date:  2011-06-30       Impact factor: 1.904

Review 6.  Clinical evaluation of osseointegration using resonance frequency analysis.

Authors:  Parth Satwalekar; Sandeep Nalla; Ramaswamy Reddy; Sheeba Glory Chowdary
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

7.  Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients.

Authors:  Kanthanat Chatvaratthana; Sita Thaworanunta; Dutmanee Seriwatanachai; Natthamet Wongsirichat
Journal:  PLoS One       Date:  2017-12-27       Impact factor: 3.240

8.  Monitoring the Changes of Material Properties at Bone-Implant Interface during the Healing Process In Vivo: A Viscoelastic Investigation.

Authors:  Hsiang-Ho Chen; Wei-Yi Lai; Tze-Jian Chee; Ya-Hui Chan; Sheng-Wei Feng
Journal:  Biomed Res Int       Date:  2017-03-08       Impact factor: 3.411

9.  Prospective multicenter non-randomized controlled study on intraosseous stability and healing period for dental implants in the posterior region.

Authors:  Shinya Homma; Yasushi Makabe; Takuya Sakai; Kenzou Morinaga; Satoru Yokoue; Hirofumi Kido; Yasutomo Yajima
Journal:  Int J Implant Dent       Date:  2018-03-29

10.  The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography.

Authors:  Se-Ryong Kang; Sung-Chul Bok; Soon-Chul Choi; Sam-Sun Lee; Min-Suk Heo; Kyung-Hoe Huh; Tae-Il Kim; Won-Jin Yi
Journal:  J Periodontal Implant Sci       Date:  2016-04-26       Impact factor: 2.614

View more