Literature DB >> 17975751

Prospective registry evaluating safety and efficacy of cobalt-chromium stent implantation in patients with de novo coronary lesions.

Paweł Buszman1, Stanisław Trznadel, Aleksander Zurakowski, Krzysztof Milewski, Leszek Kinasz, Marek Król, Marek Kondys.   

Abstract

BACKGROUND: Cobalt-chromium (Co-Cr) stents are a new type of endovascular prostheses characterised by better mechanical properties than traditional stainless steel stents. AIM: To assess the safety and efficacy of percutaneous coronary interventions (PCI) using the new Co-Cr Kos stent (Balton, Poland).
METHODS: A total of 59 patients with coronary artery diseases (76% men, aged 60+/-9 years, diabetes - 16.9%, smoking - 62.7%, 11.8% - acute myocardial infarction) underwent PCI for de novo lesions in native coronary vessels. The patients were followed for 6 months for the occurrence of cardiac events. Quantitative coronary angiography was performed at baseline and after 6 months.
RESULTS: In total, we implanted 62 stents in 59 coronary arteries. The mean diameter of the stents was 3.18+/-0.18 mm, and length - 14.62+/-2.12 mm. During a one-month follow-up period no cardiac events were noted. During a 6-month follow-up no death or new myocardial infarction were recorded. Control angiography was done in 55 (92%) subjects. Repeated target vessel revascularisation due to recurrent angina or in-stent restenosis was required in 10 (17%) patients; however, off-line core evaluation found significant re-narrowing in implanted stents (>50% diameter stenosis) only in 6 cases (10.9%). The mean late vessel lumen loss was 0.55+/-0.6 mm and stenosis 25.2+/-17.9%.
CONCLUSIONS: Implantation of the new Co-Cr Kos stent during PCI is safe and effective.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17975751

Source DB:  PubMed          Journal:  Kardiol Pol        ISSN: 0022-9032            Impact factor:   3.108


  5 in total

1.  Effect of a novel peptide, WKYMVm- and sirolimus-coated stent on re-endothelialization and anti-restenosis.

Authors:  Eun-Jae Jang; In-Ho Bae; Dae Sung Park; So-Youn Lee; Kyung Seob Lim; Jun-Kyu Park; Jae-Won Shim; Doo Sun Sim; Myung Ho Jeong
Journal:  J Mater Sci Mater Med       Date:  2015-10-05       Impact factor: 3.896

2.  Cobalt-chrome MULTI-LINK VISION-stent implantation in diabetics and complex lesions: results from the DaVinci-Registry.

Authors:  Holger M Nef; Helge Möllmann; Michael Weber; Wolfgang Auch-Schwelk; Tassilo Bonzel; Joanis Varelas; Thomas K Nordt; Joachim Schofer; Hans-Heinrich Minden; Jürgen Stumpf; Steffen Schneider; Albrecht Elsässer; Christian W Hamm
Journal:  Clin Res Cardiol       Date:  2009-08-21       Impact factor: 5.460

3.  The Control of Drug Release and Vascular Endothelialization after Hyaluronic Acid-Coated Paclitaxel Multi-Layer Coating Stent Implantation in Porcine Coronary Restenosis Model.

Authors:  In-Ho Bae; Myung Ho Jeong; Ju Han Kim; Yong Hwan Park; Kyung Seob Lim; Dae Sung Park; Jae Won Shim; Jung Ha Kim; Youngkeun Ahn; Young Joon Hong; Doo Sun Sim
Journal:  Korean Circ J       Date:  2016-12-23       Impact factor: 3.243

4.  Mechanical and physio-biological properties of peptide-coated stent for re-endothelialization.

Authors:  In-Ho Bae; Myung Ho Jeong; Dae Sung Park; Kyung Seob Lim; Jae Won Shim; Mun Ki Kim; Jun-Kyu Park
Journal:  Biomater Res       Date:  2020-01-23

5.  Novel Polymer-Free Everolimus-Eluting Stent Fabricated using Femtosecond Laser Improves Re-endothelialization and Anti-inflammation.

Authors:  In-Ho Bae; Myung Ho Jeong; Kyung Seob Lim; Dae Sung Park; Jae Won Shim; Jun-Kyu Park; Kwang Hwan Oh; Mi Rim Jin; Doo Sun Sim
Journal:  Sci Rep       Date:  2018-05-09       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.