Literature DB >> 17975233

The GlideScope-specific rigid stylet and standard malleable stylet are equally effective for GlideScope use.

Timothy P Turkstra1, Christopher C Harle, Kevin P Armstrong, Paidrig M Armstrong, Richard A Cherry, Jason Hoogstra, Philip M Jones.   

Abstract

PURPOSE: The GlideScope videolaryngoscope usually provides excellent glottic visualization, but directing an endotracheal tube (ETT) through the vocal cords can be challenging. The goal of the study was to compare the dedicated GlideScope-specific rigid stylet to the standard malleable stylet, assessed by time to intubation (TTI).
METHODS: Eighty patients requiring orotracheal intubation for elective surgery were randomly allocated to either the GlideScope rigid stylet (GRS) or a standard malleable stylet to facilitate intubation using the GlideScope. Time to intubation was recorded by blinded assessors; operators were blinded until after laryngoscopy. The operator assessed the ease of intubation using a visual analogue scale (VAS). The number of intubation attempts, number of failures, glottic grades, and use of external laryngeal manipulation were documented.
RESULTS: The median TTI was 42.7 sec (inter-quartile range (IQR) 38.9-56.7) for the GRS group compared to 39.9 sec (IQR 34.1-48.2) for the control group (P=0.07). The median VAS score for ease of intubation was 20 (IQR 12.0-33.0) for the GRS group compared to 18 (IQR 9.5-29.5) for the control group (P=0.21). There was no significant difference in TTI or VAS between stylets. The overall incidence of a Cormack-Lehane grade I or II glottic view was 98%.
CONCLUSIONS: In a group of experienced operators using the GlideScope, the dedicated GRS and the standard malleable ETT stylet are equally effective in facilitating endotracheal intubation.

Entities:  

Mesh:

Year:  2007        PMID: 17975233     DOI: 10.1007/BF03026792

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  10 in total

1.  The effect of stylet choice on the success rate of intubation using the GlideScope video laryngoscope in the emergency department.

Authors:  John C Sakles; Leah Kalin
Journal:  Acad Emerg Med       Date:  2012-01-24       Impact factor: 3.451

Review 2.  [Indirect laryngoscopy : Alternatives to securing the airway].

Authors:  R R Noppens; C Werner; T Piepho
Journal:  Anaesthesist       Date:  2010-02       Impact factor: 1.041

Review 3.  [Indirect laryngoscopy/video laryngoscopy. A review of devices used in emergency and intensive care medicine in Germany].

Authors:  N Pirlich; T Piepho; H Gervais; R R Noppens
Journal:  Med Klin Intensivmed Notfmed       Date:  2012-08-29       Impact factor: 0.840

4.  Clinical evaluation of C-MAC videolaryngoscope with or without use of stylet for endotracheal intubation in patients with cervical spine immobilization.

Authors:  Nidhi Gupta; Girija Prasad Rath; Hemanshu Prabhakar
Journal:  J Anesth       Date:  2013-03-11       Impact factor: 2.078

5.  Parker Flex-It stylet is as effective as GlideRite Rigid stylet for orotracheal intubation by Glidescope.

Authors:  Saad A Sheta; Ashraf A Abdelhalim; Ismail A ElZoughari; Tariq A AlZahrani; Abdulhamid H Al-Saeed
Journal:  Saudi Med J       Date:  2015-12       Impact factor: 1.484

6.  Comparing S-Guide® and Gliderite® Times to Assist Video laryngoscopic Intubation in Patients with Simulated Difficult Airways: A Single-Blinded Randomized Prospective Study.

Authors:  Coralie Nkoulou; Thomas Maibach; Istvan Bathory; Nicolas Fournier; Patrick Schoettker
Journal:  Turk J Anaesthesiol Reanim       Date:  2022-04

7.  Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.

Authors:  C Frerk; V S Mitchell; A F McNarry; C Mendonca; R Bhagrath; A Patel; E P O'Sullivan; N M Woodall; I Ahmad
Journal:  Br J Anaesth       Date:  2015-11-10       Impact factor: 9.166

8.  Comparison of the GlideRite to the conventional malleable stylet for endotracheal intubation by the Macintosh laryngoscope: a simulation study using manikins.

Authors:  Yong Tack Kong; Hyun Jung Lee; Ji Ung Na; Dong Hyuk Shin; Sang Kuk Han; Jeong Hun Lee; Pil Cho Choi
Journal:  Clin Exp Emerg Med       Date:  2016-03-31

9.  Comparison of intubation times using a manikin with an immobilized cervical spine: Macintosh laryngoscope vs. GlideScope vs. fiberoptic bronchoscope.

Authors:  Jung-In Ko; Sang Ook Ha; Min Seok Koo; Miyoung Kwon; Jieun Kim; Jin Jeon; So Hee Park; Sangwoo Shim; Youjin Chang; Taejin Park
Journal:  Clin Exp Emerg Med       Date:  2015-12-28

10.  Canadian Airway Focus Group updated consensus-based recommendations for management of the difficult airway: part 1. Difficult airway management encountered in an unconscious patient.

Authors:  J Adam Law; Laura V Duggan; Mathieu Asselin; Paul Baker; Edward Crosby; Andrew Downey; Orlando R Hung; Philip M Jones; François Lemay; Rudiger Noppens; Matteo Parotto; Roanne Preston; Nick Sowers; Kathryn Sparrow; Timothy P Turkstra; David T Wong; George Kovacs
Journal:  Can J Anaesth       Date:  2021-06-18       Impact factor: 5.063

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.