Determination of the mean normal prothrombin time for assessment of international normalized ratios. Usefulness of lyophilized plasma.

R H Peters1, A M van den Besselaar, F M Olthuis.   

Abstract

To report a Prothrombin Time (PT) as International Normalized Ratio in controlling oral anticoagulant therapy, the Mean Normal PT (MNPT) is required. To correct for methodological differences in performing the PT test, each laboratory should determine its own MNPT for each batch of reagent using fresh blood samples from a large number of normal individuals. This would be a laborious procedure. Two models for simplified assessment of MNPT were investigated by two laboratories in a collaborative study. According to the models, the MNPT of a new batch of reagent is calculated, using the PT of a lyophilized control plasma measured with the new batch and a reference batch, as well as the MNPT of the reference batch obtained with fresh samples. Experimental results were obtained with 19 batches of bovine thromboplastin, 4 lyophilized normal control plasmas and fresh blood samples of 40 normal individuals. The PTs of the 4 lyophilized normal control plasmas were not identical to the MNPT of the fresh normal samples and also different from each other. Therefore, the uncorrected PTs of these control plasmas cannot be used as MNPT. In general, there was good agreement between measured and calculated MNPT, although some control plasmas gave better results than others. There were no significant differences between the results obtained by both calculation models.

Entities:  

Mesh:

Year:  1991        PMID: 1796393

Source DB:  PubMed          Journal:  Thromb Haemost        ISSN: 0340-6245            Impact factor:   5.249


  4 in total

1.  Multicentre evaluation of the Thrombotest International Sensitivity Index used with a steel ball coagulometer.

Authors:  A M van den Besselaar; R H Peters
Journal:  J Clin Pathol       Date:  1996-05       Impact factor: 3.411

2.  Effect of thromboplastin and coagulometer interaction on the precision of the International Normalised Ratio.

Authors:  D W Pi; J M Raboud; C Filby; C J Carter
Journal:  J Clin Pathol       Date:  1995-01       Impact factor: 3.411

3.  Evaluation of the Steelex M600H coagulometer prothrombin time-international normalized ratio assay with Steelex test reagents.

Authors:  Yasemin U Budak; Kağan Huysal; Murat Polat; Gülsevil Tarakçi; Hakan Uçar
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

4.  Radiopaque Hemocompatible Ruminant-Sourced Gut Material with Antimicrobial Physiognomies for Biomedical Applications in Diabetics.

Authors:  Nimmy K Francis; Harpreet S Pawar; Santanu Dhara; Anirban Mitra; Analava Mitra
Journal:  ACS Omega       Date:  2017-03-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.