Literature DB >> 17960684

An ABJS Best Paper: Dynamic intraoperative ligament balancing for total knee arthroplasty.

Darryl D D'Lima1, Shantanu Patil, Nikolai Steklov, Clifford W Colwell.   

Abstract

Complications after total knee arthroplasty, such as malalignment, instability, and excessive wear, have been attributed to poor soft tissue balance. Traditional instruments that assist in intraoperative soft tissue balancing rely on static measurements. We used a custom tibial trial, instrumented with force transducers, for dynamic measurement of soft tissue balance. Six cadaver knees and two patients were implanted with the trial tray along with a standard femoral component and a tibial insert. We recorded tibial forces during passive knee flexion, after the initial bone cuts were made, after soft tissue balancing, and after replacing the selected optimal insert with one that was 2 mm thicker. In all knees, substantial imbalance in tibial forces initially was recorded. Soft tissue balancing substantially reduced the imbalance. Although reasonable balance was achieved at 0-degree and 90-degree flexion, there was some measurable imbalance at flexion angles other than 0 degrees and 90 degrees. Increasing the thickness of the insert by 2 mm substantially increased net tibial forces. Inconsistent soft tissue balance may explain some of the wide variation in knee kinematics. Surgical navigation systems have reduced the variability in component alignment. An instrumented tibial trial can be a valuable adjunct to directly measure soft tissue balance. (C) 2007 Lippincott Williams & Wilkins, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17960684

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  19 in total

1.  Ligament tension in the ACL-deficient knee: assessment of medial and lateral gaps.

Authors:  David Mayman; Christopher Plaskos; Daniel Kendoff; G Wernecke; Andrew D Pearle; Richard Laskin
Journal:  Clin Orthop Relat Res       Date:  2009-02-24       Impact factor: 4.176

2.  Agreements between different methods of gap balance estimation in cruciate-retaining total knee arthroplasty.

Authors:  Yong In; Seok-Jung Kim; Jung-Man Kim; Young-Kyun Woo; Nam-Yong Choi; Jun-Won Kang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-10-31       Impact factor: 4.342

3.  Can we define envelope of laxity during navigated knee arthroplasty?

Authors:  K M Ghosh; A P Blain; L Longstaff; S Rushton; A A Amis; D J Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-06       Impact factor: 4.342

4.  Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection.

Authors:  Dae-Hee Lee; Jong-Hoon Park; Dong-Ik Song; Debabrata Padhy; Woong-Kyo Jeong; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-03       Impact factor: 4.342

5.  The 2011 ABJS Nicolas Andry Award: 'Lab'-in-a-knee: in vivo knee forces, kinematics, and contact analysis.

Authors:  Darryl D D'Lima; Shantanu Patil; Nicolai Steklov; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2011-05-20       Impact factor: 4.176

6.  Results of total knee arthroplasty with NexGen LPS-Flex for osteoarthritis in the valgus knee: a study of 26 patients followed for a minimum of 2 years.

Authors:  Naoki Nakano; Tomoyuki Matsumoto; Hirotsugu Muratsu; Takehiko Matsushita; Koji Takayama; Tokio Matsuzaki; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-07-17

7.  The pie-crusting technique using a blade knife for medial collateral ligament release is unreliable in varus total knee arthroplasty.

Authors:  Dai-Soon Kwak; Yong In; Tae Kyun Kim; Han Suk Cho; In Jun Koh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-07       Impact factor: 4.342

8.  High tibial slope correlates with increased posterior tibial translation in healthy knees.

Authors:  Imke Schatka; Andreas Weiler; Tobias M Jung; Thula C Walter; Clemens Gwinner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-09-09       Impact factor: 4.342

9.  Development of a pneumatic tensioning device for gap measurement during total knee arthroplasty.

Authors:  Dai-Soon Kwak; Chae-Gwan Kong; Seung-Ho Han; Dong-Hyun Kim; Yong In
Journal:  Clin Orthop Surg       Date:  2012-08-14

10.  A new method to measure ligament balancing in total knee arthroplasty: laxity measurements in 100 knees.

Authors:  Eirik Aunan; Thomas Kibsgård; John Clarke-Jenssen; Stephan M Röhrl
Journal:  Arch Orthop Trauma Surg       Date:  2012-05-13       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.