Literature DB >> 17951355

Pulmonary nodules: 3D volumetric measurement with multidetector CT--effect of intravenous contrast medium.

Osamu Honda1, Takeshi Johkoh, Hiromitsu Sumikawa, Atsuo Inoue, Noriyuki Tomiyama, Naoki Mihara, Yuka Fujita, Mitsuko Tsubamoto, Masahiro Yanagawa, Tadahisa Daimon, Javzandulam Natsag, Hironobu Nakamura.   

Abstract

PURPOSE: To retrospectively evaluate the effect of contrast medium on the three-dimensional volumetric measurement of pulmonary nodules.
MATERIALS AND METHODS: The study was approved by the local institutional review committee, with waiver of informed consent. Sixty pulmonary nodules in 60 patients (17 women, 43 men; age range, 29-82 years) were imaged before and after administration of contrast medium with a 64-channel multidetector computed tomographic (CT) scanner; reconstructed images with a section thickness of 0.625 mm were obtained by using a bone algorithm and a standard algorithm. Volumetric measurements of pulmonary nodules were performed by using commercially available software, and the postcontrast volume ratio was calculated by dividing the postcontrast volume by the precontrast volume. Precontrast and postcontrast volumes were then analyzed by using a Wilcoxon signed rank test.
RESULTS: The median measured volumes of pulmonary nodules were 817 mm(3) (precontrast imaging, bone algorithm), 887 mm(3) (postcontrast imaging, bone algorithm), 812 mm(3) (precontrast imaging, standard algorithm), and 855 mm(3) (postcontrast imaging, standard algorithm). The measured volumes obtained with the bone algorithm were significantly larger than those obtained with the standard algorithm, both before and after administration of contrast medium (P < .01); with both the standard algorithm and the bone algorithm, the measured postcontrast volumes were significantly larger than the precontrast volumes (P < .01). The postcontrast volume ratio was more than 1.0 in 45 cases (75%) when the bone algorithm was used and in 53 cases (88%) when the standard algorithm was used. The mean postcontrast volume ratio was 1.054 with the bone algorithm and 1.065 with the standard algorithm.
CONCLUSION: The measured volume of pulmonary nodules obtained by using three-dimensional volumetric software increased after administration of contrast medium. Moreover, the measured volume of pulmonary nodules that was obtained with the bone algorithm was larger than that obtained with the standard algorithm, regardless of whether contrast medium was used. (c) RSNA, 2007.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17951355     DOI: 10.1148/radiol.2453062116

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Computer-assisted solid lung nodule 3D volumetry on CT: influence of scan mode and iterative reconstruction: a CT phantom study.

Authors:  Adriaan Coenen; Osamu Honda; Eric J van der Jagt; Noriyuki Tomiyama
Journal:  Jpn J Radiol       Date:  2013-08-18       Impact factor: 2.374

Review 2.  European and North American lung cancer screening experience and implications for pulmonary nodule management.

Authors:  Arjun Nair; David M Hansell
Journal:  Eur Radiol       Date:  2011-08-10       Impact factor: 5.315

3.  Pulmonary Nodules: growth rate assessment in patients by using serial CT and three-dimensional volumetry.

Authors:  Jane P Ko; Erika J Berman; Manmeen Kaur; James S Babb; Elan Bomsztyk; Alissa K Greenberg; David P Naidich; Henry Rusinek
Journal:  Radiology       Date:  2011-12-09       Impact factor: 11.105

4.  Variability of pulmonary nodule volumetry on coronary CT angiograms.

Authors:  Erique Pinto; Diana Penha; Bruno Hochhegger; Colin Monaghan; Edson Marchiori; Luís Taborda-Barata; Klaus Irion
Journal:  Medicine (Baltimore)       Date:  2022-09-02       Impact factor: 1.817

5.  The impact of lung parenchyma attenuation on nodule volumetry in lung cancer screening.

Authors:  Diana Penha; Erique Pinto; Bruno Hochhegger; Colin Monaghan; Edson Marchiori; Luís Taborda-Barata; Klaus Irion
Journal:  Insights Imaging       Date:  2021-06-25

6.  The Effects of Iodine Attenuation on Pulmonary Nodule Volumetry using Novel Dual-Layer Computed Tomography Reconstructions.

Authors:  A M den Harder; F Bangert; R W van Hamersvelt; T Leiner; Julien Milles; A M R Schilham; M J Willemink; P A de Jong
Journal:  Eur Radiol       Date:  2017-07-04       Impact factor: 5.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.