In vivo and in vitro differences in the charge-injection and electrochemical properties of iridium oxide electrodes.

Stuart F Cogan1.   

Abstract

The electrochemical response of activated iridium oxide (AIROF) electrodes implanted acutely in the subretinal space of the rabbit is compared with in vitro measurements in model electrolytes. Voltage transients during current pulsing, cyclic voltammetry, impedance spectroscopy and open-circuit potential measurements were compared. Subretinal charge injection by constant current pulsing required significantly greater driving voltages due to both higher access resistances (iR) and large electrochemical polarization across the electrode-tissue interface. Differences in the in vivo and in vitro open-circuit potentials were also noted. The data suggest that the buffering capacity in the subretinal space, at least in the acute study, is higher than that in inorganic models of interstitial fluid. Possible origins of these differences in terms of electrode-tissue interactions are discussed.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17946868     DOI: 10.1109/IEMBS.2006.259654

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  11 in total

1.  Evaluation of high-perimeter electrode designs for deep brain stimulation.

Authors:  Bryan Howell; Warren M Grill
Journal:  J Neural Eng       Date:  2014-07-16       Impact factor: 5.379

Review 2.  Wireless microstimulators for neural prosthetics.

Authors:  Mesut Sahin; Victor Pikov
Journal:  Crit Rev Biomed Eng       Date:  2011

3.  Characterization of high capacitance electrodes for the application of direct current electrical nerve block.

Authors:  Tina Vrabec; Niloy Bhadra; Jesse Wainright; Narendra Bhadra; Manfred Franke; Kevin Kilgore
Journal:  Med Biol Eng Comput       Date:  2015-09-11       Impact factor: 2.602

4.  Maximizing Charge Injection Limits of Iridium Oxide Electrodes with a Programmable Anodic Bias Circuit.

Authors:  Alpaslan Ersöz; Insoo Kim; Martin Han
Journal:  Int IEEE EMBS Conf Neural Eng       Date:  2021-06-02

5.  Neural electrode degradation from continuous electrical stimulation: comparison of sputtered and activated iridium oxide.

Authors:  Sandeep Negi; Rajmohan Bhandari; Loren Rieth; Rick Van Wagenen; Florian Solzbacher
Journal:  J Neurosci Methods       Date:  2009-10-28       Impact factor: 2.390

6.  Electrochemical safety limits for clinical stimulation investigated using depth and strip electrodes in the pig brain.

Authors:  Ritwik Vatsyayan; Daniel Cleary; Joel R Martin; Eric Halgren; Shadi A Dayeh
Journal:  J Neural Eng       Date:  2021-06-04       Impact factor: 5.043

7.  In vivo comparison of the charge densities required to evoke motor responses using novel annular penetrating microelectrodes.

Authors:  Emma K Brunton; Bjorn Winther-Jensen; Chun Wang; Edwin B Yan; Saman Hagh Gooie; Arthur J Lowery; Ramesh Rajan
Journal:  Front Neuroeng       Date:  2015-05-12

8.  Substrate arrays of iridium oxide microelectrodes for in vitro neuronal interfacing.

Authors:  Shady Gawad; Michele Giugliano; Marc Heuschkel; Börge Wessling; Henry Markram; Uwe Schnakenberg; Philippe Renaud; Hywel Morgan
Journal:  Front Neuroeng       Date:  2009-01-22

9.  In vivo comparison of the charge densities required to evoke motor responses using novel annular penetrating microelectrodes.

Authors:  Emma K Brunton; Bjorn Winther-Jensen; Chun Wang; Edwin B Yan; Saman Hagh Gooie; Arthur J Lowery; Ramesh Rajan
Journal:  Front Neurosci       Date:  2015-05-12       Impact factor: 4.677

10.  Electrochemical properties of titanium nitride nerve stimulation electrodes: an in vitro and in vivo study.

Authors:  Suzan Meijs; Morten Fjorback; Carina Jensen; Søren Sørensen; Kristian Rechendorff; Nico J M Rijkhoff
Journal:  Front Neurosci       Date:  2015-08-04       Impact factor: 4.677

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.