Literature DB >> 17944337

Clinical outcome study of customized zirconia abutments for single-implant restorations.

Luigi Canullo1.   

Abstract

PURPOSE: This study evaluated the clinical performance of cemented customized zirconia abutments. Additionally, the marginal fit between the selected implant components was measured and the clinical gingival response was monitored.
MATERIALS AND METHODS: Twenty-five patients were consecutively selected for a prospective study of 30 implant-supported single-tooth restorations. Customized titanium post and zirconia abutment complexes were prepared, and scanning electron microscopy (SEM) analysis was used to study bicomponent marginal gaps. The abutments were screwed onto the implants and restored with all-ceramic crowns. Plaque and gingival indices were recorded at 6 monthly intervals over a 36- to 44-month period.
RESULTS: SEM analysis showed mean marginal gaps of 10.161 microm (SD: 0.7) horizontally and 4.783 microm (SD: 0.67) vertically. Abutment fractures and screw loosening were neither reported nor observed throughout the clinical observation period. Mean Plaque Index scores were 0.57 (SD: 0.32) on abutments and 0.74 (SD: 0.34) on teeth, while mean Gingival Index scores were 0.54 (SD: 0.2) on abutments and 0.72 (SD: 0.3) on teeth.
CONCLUSIONS: These preliminary results suggest that metallic-zirconia abutments may be comparable to currently available esthetic implant abutments.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17944337

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  14 in total

Review 1.  Mechanical resistance of zirconium implant abutments: a review of the literature.

Authors:  R Velázquez-Cayón; C Vaquero-Aguilar; D Torres-Lagares; M Jiménez-Melendo; J-L Gutiérrez-Pérez
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

2.  Comparison of pro-inflammatory cytokines and bone metabolism mediators around titanium and zirconia dental implant abutments following a minimum of 6 months of clinical function.

Authors:  Christopher A Barwacz; Kim A Brogden; Clark M Stanford; Deborah V Dawson; Erica N Recker; Derek Blanchette
Journal:  Clin Oral Implants Res       Date:  2014-01-13       Impact factor: 5.977

3.  Impact of abutment material on peri-implant soft tissue color. An in vitro study.

Authors:  Leticia Sala; Antonio Bascones-Martínez; Ana Carrillo-de-Albornoz
Journal:  Clin Oral Investig       Date:  2016-11-22       Impact factor: 3.573

4.  Fracture behavior of zirconia implant abutments is influenced by superstructure-geometry.

Authors:  Frank P Nothdurft; Konrad Neumann; Andreas W Knauber
Journal:  Clin Oral Investig       Date:  2013-09-20       Impact factor: 3.573

5.  Cellular viability and genetic expression of human gingival fibroblasts to zirconia with enamel matrix derivative (Emdogain®).

Authors:  Yong-Dae Kwon; Hyun-Jung Choi; Heesu Lee; Jung-Woo Lee; Hans-Peter Weber; Ahran Pae
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

Review 6.  Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis.

Authors:  Amr G ElHoussiney; He Zhang; Jinlin Song; Ping Ji; Lu Wang; Sheng Yang
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-26

7.  Tensile Bond Strength of Three Custom-made Tooth-Colored Implant Superstructures to Titanium Inserts.

Authors:  Mitra Zirak; Mahroo Vojdani; Amir Ali Reza Khaledi; Mitra Farzin
Journal:  J Dent (Shiraz)       Date:  2019-06

8.  Mechanical testing of thin-walled zirconia abutments.

Authors:  Luigi Canullo; Paulo G Coelho; Estevam A Bonfante
Journal:  J Appl Oral Sci       Date:  2013 Jan-Feb       Impact factor: 2.698

9.  Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region.

Authors:  Guerino Paolantoni; Gaetano Marenzi; Andrea Blasi; Jolanda Mignogna; Gilberto Sammartino
Journal:  Biomed Res Int       Date:  2016-01-04       Impact factor: 3.411

Review 10.  Clinical reliability of zirconium abutment in implant restorations in the English and Korean literature.

Authors:  Su-Been Yu; Bong-Gyu Song; Kyeong-Jun Cheon; Ju-Won Kim; Young-Hee Kim; Byoung-Eun Yang
Journal:  Maxillofac Plast Reconstr Surg       Date:  2018-09-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.