Literature DB >> 17938838

Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus.

Justin T Baca1, David N Finegold, Sanford A Asher.   

Abstract

One approach to the noninvasive monitoring of blood glucose concentration is to monitor glucose concentrations in tear fluid. While several methods for sensing glucose in tear fluid have been proposed, controversy remains as to the precise concentrations of tear glucose in normal and diabetic subjects and as to whether tear fluid glucose concentrations correlate with blood glucose concentrations. This review covers the present understanding of the physiology of glucose transport in tears, the regulation of the aqueous tear fraction, and studies of tear glucose concentration over the last 80 years. The various tear collection methods employed greatly influence the measured tear glucose concentrations. Studies that involve mechanical irritation of the conjunctiva during sampling measure the highest tear glucose concentrations, while studies that avoid tear stimulation measure the lowest concentrations. Attempts to monitor tear glucose concentration in situ by using contact lens-based sensing devices are discussed, and new observations are presented of tear glucose concentration obtained by a method designed to avoid tear stimulation. These studies indicate the importance of the sampling method in determining tear glucose concentrations. On the basis of these results, we discuss the future of in vivo tear glucose sensing and outline the studies needed to resolve the remaining questions about the relationship between tear and blood glucose concentrations.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17938838     DOI: 10.1016/s1542-0124(12)70094-0

Source DB:  PubMed          Journal:  Ocul Surf        ISSN: 1542-0124            Impact factor:   5.033


  33 in total

1.  A disposable tear glucose biosensor-part 1: design and concept testing.

Authors:  Daniel K Bishop; Jeffrey T La Belle; Stephen R Vossler; Dharmendra R Patel; Curtiss B Cook
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

2.  A disposable tear glucose biosensor-part 2: system integration and model validation.

Authors:  Jeffrey T La Belle; Daniel K Bishop; Stephen R Vossler; Dharmendra R Patel; Curtiss B Cook
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

Review 3.  Wearable biosensors for healthcare monitoring.

Authors:  Jayoung Kim; Alan S Campbell; Berta Esteban-Fernández de Ávila; Joseph Wang
Journal:  Nat Biotechnol       Date:  2019-02-25       Impact factor: 54.908

Review 4.  Noninvasive diagnostic devices for diabetes through measuring tear glucose.

Authors:  Jin Zhang; William Hodge; Cindy Hutnick; Xianbin Wang
Journal:  J Diabetes Sci Technol       Date:  2011-01-01

5.  A Disposable Tear Glucose Biosensor-Part 5: Improvements in Reagents and Tear Sampling Component.

Authors:  Chi En Lin; Yuka Ito; Anna Deng; Jared Johns; Daniel Matloff; Curtiss B Cook; Koji Sode; Jeffrey T La Belle
Journal:  J Diabetes Sci Technol       Date:  2018-04-18

6.  A contact lens with embedded sensor for monitoring tear glucose level.

Authors:  Huanfen Yao; Angela J Shum; Melissa Cowan; Ilkka Lähdesmäki; Babak A Parviz
Journal:  Biosens Bioelectron       Date:  2010-12-31       Impact factor: 10.618

7.  Flexible three-dimensional electrochemical glucose sensor with improved sensitivity realized in hybrid polymer microelectromechanical systems technique.

Authors:  Jasbir N Patel; Bonnie L Gray; Bozena Kaminska; Byron D Gates
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

8.  A disposable tear glucose biosensor--part 3: assessment of enzymatic specificity.

Authors:  Kenneth Lan; Kenyon McAferty; Pankti Shah; Erica Lieberman; Dharmendra R Patel; Curtiss B Cook; Jeffrey T La Belle
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

9.  A Disposable Tear Glucose Biosensor-Part 4: Preliminary Animal Model Study Assessing Efficacy, Safety, and Feasibility.

Authors:  Jeffrey T La Belle; Erica Engelschall; Kenneth Lan; Pankti Shah; Neil Saez; Stephanie Maxwell; Teagan Adamson; Michelle Abou-Eid; Kenyon McAferty; Dharmendra R Patel; Curtiss B Cook
Journal:  J Diabetes Sci Technol       Date:  2014-01-01

10.  Glucose-sensitive silicone hydrogel contact lens toward tear glucose monitoring.

Authors:  Ramachandram Badugu; Edward Albert Reece; Joseph R Lakowicz
Journal:  J Biomed Opt       Date:  2018-05       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.