Literature DB >> 20307390

A disposable tear glucose biosensor-part 2: system integration and model validation.

Jeffrey T La Belle1, Daniel K Bishop, Stephen R Vossler, Dharmendra R Patel, Curtiss B Cook.   

Abstract

BACKGROUND: We presented a concept for a tear glucose sensor system in an article by Bishop and colleagues in this issue of Journal of Diabetes Science and Technology. A unique solution to collect tear fluid and measure glucose was developed. Individual components were selected, tested, and optimized, and system error modeling was performed. Further data on prototype testing are now provided.
METHODS: An integrated fluidics portion of the prototype was designed, cast, and tested. A sensor was created using screen-printed sensors integrated with a silicone rubber fluidics system and absorbent polyurethane foam. A simulated eye surface was prepared using fluid-saturated poly(2-hydroxyethyl methacrylate) sheets, and the disposable prototype was tested for both reproducibility at 0, 200, and 400 microM glucose (n = 7) and dynamic range of glucose detection from 0 to 1000 microM glucose.
RESULTS: From the replicated runs, an established relative standard deviation of 15.8% was calculated at 200 microM and a lower limit of detection was calculated at 43.4 microM. A linear dynamic range was demonstrated from 0 to 1000 microM with an R(2) of 99.56%. The previously developed model predicted a 14.9% variation. This compares to the observed variance of 15.8% measured at 200 microM glucose.
CONCLUSION: With the newly designed fluidics component, an integrated tear glucose prototype was assembled and tested. Testing of this integrated prototype demonstrated a satisfactory lower limit of detection for measuring glucose concentration in tears and was reproducible across a physiological sampling range. The next step in the device design process will be initial animal studies to evaluate the current prototype for factors such as eye irritation, ease of use, and correlation with blood glucose. (c) 2010 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20307390      PMCID: PMC2864165          DOI: 10.1177/193229681000400210

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  8 in total

1.  Human factors engineering and patient safety.

Authors:  J Gosbee
Journal:  Qual Saf Health Care       Date:  2002-12

2.  Tissue engineering: the end of the beginning.

Authors:  Michael J Lysaght; Anne L Hazlehurst
Journal:  Tissue Eng       Date:  2004 Jan-Feb

3.  A disposable tear glucose biosensor-part 1: design and concept testing.

Authors:  Daniel K Bishop; Jeffrey T La Belle; Stephen R Vossler; Dharmendra R Patel; Curtiss B Cook
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

4.  Tear glucose dynamics in diabetes mellitus.

Authors:  Jennifer D Lane; David M Krumholz; Robert A Sack; Carol Morris
Journal:  Curr Eye Res       Date:  2006-11       Impact factor: 2.424

5.  Designing the design phase of critical care devices: a cognitive approach.

Authors:  Sameer Malhotra; Archana Laxmisan; Alla Keselman; Jiajie Zhang; Vimla L Patel
Journal:  J Biomed Inform       Date:  2005-02       Impact factor: 6.317

6.  Tear glucose detection of hyperglycemia.

Authors:  A R Gasset; L E Braverman; M C Fleming; R A Arky; B R Alter
Journal:  Am J Ophthalmol       Date:  1968-03       Impact factor: 5.258

7.  Analysis of tear glucose concentration with electrospray ionization mass spectrometry.

Authors:  Christopher R Taormina; Justin T Baca; Sanford A Asher; Joseph J Grabowski; David N Finegold
Journal:  J Am Soc Mass Spectrom       Date:  2006-11-02       Impact factor: 3.109

Review 8.  Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus.

Authors:  Justin T Baca; David N Finegold; Sanford A Asher
Journal:  Ocul Surf       Date:  2007-10       Impact factor: 5.033

  8 in total
  5 in total

1.  Toward the Development of a Glucose Dehydrogenase-Based Saliva Glucose Sensor Without the Need for Sample Preparation.

Authors:  Chi Lin; Breanna Pratt; Mackenzie Honikel; Alaina Jenish; Bhavna Ramesh; Amnah Alkhan; Jeffrey T La Belle
Journal:  J Diabetes Sci Technol       Date:  2017-06-19

2.  A disposable tear glucose biosensor--part 3: assessment of enzymatic specificity.

Authors:  Kenneth Lan; Kenyon McAferty; Pankti Shah; Erica Lieberman; Dharmendra R Patel; Curtiss B Cook; Jeffrey T La Belle
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

3.  A Disposable Tear Glucose Biosensor-Part 4: Preliminary Animal Model Study Assessing Efficacy, Safety, and Feasibility.

Authors:  Jeffrey T La Belle; Erica Engelschall; Kenneth Lan; Pankti Shah; Neil Saez; Stephanie Maxwell; Teagan Adamson; Michelle Abou-Eid; Kenyon McAferty; Dharmendra R Patel; Curtiss B Cook
Journal:  J Diabetes Sci Technol       Date:  2014-01-01

4.  Glucose-responsive hydrogel electrode for biocompatible glucose transistor.

Authors:  Taira Kajisa; Toshiya Sakata
Journal:  Sci Technol Adv Mater       Date:  2017-01-09       Impact factor: 8.090

5.  Development of a Ratiometric Fluorescent Glucose Sensor Using an Oxygen-Sensing Membrane Immobilized with Glucose Oxidase for the Detection of Glucose in Tears.

Authors:  Hong Dinh Duong; Ok-Jae Sohn; Jong Il Rhee
Journal:  Biosensors (Basel)       Date:  2020-07-29