Literature DB >> 17921902

Scala tympani cochleostomy I: results of a survey.

Oliver F Adunka1, Craig A Buchman.   

Abstract

OBJECTIVE: To assess current surgical techniques for scala tympani cochlear implantation among North American surgeons. MATERIAL: A survey was distributed to all cochlear implant surgeons participating in the 2006 William House Cochlear Implant Study Group in Toronto, Canada. Participants were asked to anonymously identify their routine surgical practices. Images of trans-facial recess approaches to the round window and cochlear promontory were used in a multiple-choice fashion to assess the surgeon's typical exposure and cochleostomy location. Returned questionnaires were electronically processed and evaluated.
RESULTS: Fifty-five (75%) of 73 returned surveys had adequate data validity and availability. Landmark identification and preferred cochleostomy locations varied greatly. About 20% of surgeons selected cochleostomy locations superior to the round window membrane. Cochleostomy size and location appeared to be influenced by surgical experience and whether or not the round window overhang was drilled off.
CONCLUSION: This survey clearly documents marked variations in surgical techniques for scala tympani cochlear implantation. Future studies should more clearly define the surgical anatomy of this region for appropriate placement of a scala tympani cochleostomy. These findings may ultimately have an impact on hearing and neural preservation cochlear implant surgeries.

Entities:  

Mesh:

Year:  2007        PMID: 17921902     DOI: 10.1097/MLG.0b013e3181453a6c

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  18 in total

1.  Impact of the surgical experience on cochleostomy location: a comparative temporal bone study between endaural and posterior tympanotomy approaches for cochlear implantation.

Authors:  Clair Vandersteen; Thomas Demarcy; Coralie Roger; Eric Fontas; Charles Raffaelli; Nicholas Ayache; Hervé Delingette; Nicolas Guevara
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-10-16       Impact factor: 2.503

Review 2.  Soft cochlear implantation: rationale for the surgical approach.

Authors:  David R Friedland; Christina Runge-Samuelson
Journal:  Trends Amplif       Date:  2009-06

3.  Clinical validation of percutaneous cochlear implant surgery: initial report.

Authors:  Robert Frederick Labadie; Jack H Noble; Benoit M Dawant; Ramya Balachandran; Omid Majdani; J Michael Fitzpatrick
Journal:  Laryngoscope       Date:  2008-06       Impact factor: 3.325

4.  Cochleostomy placement and vestibular injury.

Authors:  Charley C Della Santina
Journal:  Otolaryngol Head Neck Surg       Date:  2008-06       Impact factor: 3.497

5.  Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes.

Authors:  George B Wanna; Jack H Noble; Matthew L Carlson; René H Gifford; Mary S Dietrich; David S Haynes; Benoit M Dawant; Robert F Labadie
Journal:  Laryngoscope       Date:  2014-05-30       Impact factor: 3.325

6.  [Insertion results for Contour™ and Contour Advance™ electrodes: are there individual learning curves?].

Authors:  A Aschendorff; T Klenzner; S Arndt; R Beck; C Schild; L Röddiger; W Maier; R Laszig
Journal:  HNO       Date:  2011-05       Impact factor: 1.284

7.  Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis.

Authors:  Jessica Teymouri; Timothy E Hullar; Timothy A Holden; Richard A Chole
Journal:  Otol Neurotol       Date:  2011-08       Impact factor: 2.311

8.  Evaluation of round window accessibility to cochlear implant insertion.

Authors:  Annabelle C Leong; Dan Jiang; Andreas Agger; Alec Fitzgerald-O'Connor
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-07-18       Impact factor: 2.503

9.  Multicenter surgical experience evaluation on the Mid-Scala electrode and insertion tools.

Authors:  Dzemal Gazibegovic; Eva M Bero
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-08-11       Impact factor: 2.503

10.  Role of electrode placement as a contributor to variability in cochlear implant outcomes.

Authors:  Charles C Finley; Timothy A Holden; Laura K Holden; Bruce R Whiting; Richard A Chole; Gail J Neely; Timothy E Hullar; Margaret W Skinner
Journal:  Otol Neurotol       Date:  2008-10       Impact factor: 2.311

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.