Literature DB >> 17920495

Accuracy of cone-beam computed tomography imaging of the temporomandibular joint: comparisons with panoramic radiology and linear tomography.

Oana Bida Honey1, William Charles Scarfe, Michael J Hilgers, Kathleen Klueber, Anibal M Silveira, Bruce S Haskell, Allan G Farman.   

Abstract

INTRODUCTION: Cone-beam computed tomography (CBCT) is increasingly being used as an imaging modality, particularly in the assessment of the temporomandibular joint (TMJ). A blinded observational cross-sectional in-vitro study was conducted to compare the diagnostic accuracy of observers viewing images made with CBCT, panoramic radiography, and linear tomography. The task was to detect cortical erosions affecting the mandibular condylar head.
METHODS: The sample consisted of 37 TMJ articulations from 30 skulls with either normal condylar morphology (n = 19) or erosion of the lateral pole (n = 18). The articulations were imaged by using corrected angle linear tomography (TOMO), normal (Pan-N) and TMJ-specific (Pan-TM) panoramic radiography, and CBCT. Digital images were obtained with photostimulable phosphor plates for all modalities except CBCT. The CBCT detector used an amorphous silicon flat-panel array combined with cesium iodide. Images and 10 rereads were presented to 10 observers on a flat-panel display at a pixel-to-monitor ratio of 1:1. CBCT multi-planar images were presented both statically (CBCT-S) and interactively (CBCT-I). The observers were permitted to scroll through axial (0.4 mm) and para-sagittal (1 mm) sections and then independently rate their confidence about the presence or absence of cortical erosion. Intraobserver reliability was determined by weighted kappa and diagnostic accuracy by the fitted area under the ROC curve. Means were compared by using ANOVA (P < or =.05).
RESULTS: Intraobserver reliability was moderate (0.57 +/- 0.22; range, 0.34-0.78). Pan-N (0.72 +/- 0.15), CBCT-I (0.65 +/- 0.21), and CBCT-S (0.65 +/- 0.17) reliability was significantly greater than TOMO (0.44 +/- 0.25). The diagnostic accuracy of CBCT-I (0.95 +/- 0.05) and CBCT-S (0.77 +/- 0.17) was significantly greater than all other modalities (Pan-N [0.64 +/- 0.11], Pan-TM [0.55 +/- 0.11], TOMO [0.58 +/- 0.15]). CBCT-I was also more accurate than CBCT-S, and Pan-N was more accurate than Pan-TM and TOMO.
CONCLUSIONS: CBCT images provide superior reliability and greater accuracy than TOMO and TMJ panoramic projections in the detection of condylar cortical erosion.

Entities:  

Mesh:

Year:  2007        PMID: 17920495     DOI: 10.1016/j.ajodo.2005.10.032

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  67 in total

Review 1.  Temporomandibular joint diagnostics using CBCT.

Authors:  T A Larheim; A-K Abrahamsson; M Kristensen; L Z Arvidsson
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

2.  Bilateral bifid mandibular condyles diagnosed with three-dimensional reconstruction.

Authors:  J M Tanner; A H Friedlander; T I Chang
Journal:  Dentomaxillofac Radiol       Date:  2012-01-12       Impact factor: 2.419

3.  Comparative study between conventional and cone beam CT-synthesized half and total skull cephalograms.

Authors:  G S Liedke; E L Delamare; M B Vizzotto; H L D da Silveira; J R Prietsch; V Dutra; H E D da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2012-02       Impact factor: 2.419

4.  A comparative study of accuracy of detection of surface osseous changes in the temporomandibular joint using multidetector CT and cone beam CT.

Authors:  E H Zain-Alabdeen; R I Alsadhan
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

Review 5.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

Review 6.  The current status of cone beam computed tomography imaging in orthodontics.

Authors:  S Kapila; R S Conley; W E Harrell
Journal:  Dentomaxillofac Radiol       Date:  2011-01       Impact factor: 2.419

7.  Diagnostic accuracy of cone beam computed tomography and conventional multislice spiral tomography in sheep mandibular condyle fractures.

Authors:  Y Sirin; K Guven; S Horasan; S Sencan
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

8.  Usefulness of cone beam computed tomography in temporomandibular joints with soft tissue pathology.

Authors:  M Alkhader; A Kuribayashi; N Ohbayashi; S Nakamura; T Kurabayashi
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

9.  Relationship between mandibular condyle and articular eminence cortication with mandibular cortical index on cone-beam CT.

Authors:  Eda Didem Yalcin; Cigdem Bozan
Journal:  Surg Radiol Anat       Date:  2019-11-25       Impact factor: 1.246

10.  Brain imaging with a flat detector C-arm : Technique and clinical interest of XperCT.

Authors:  M Söderman; D Babic; S Holmin; T Andersson
Journal:  Neuroradiology       Date:  2008-06-17       Impact factor: 2.804

View more