Literature DB >> 17904394

Cyclic fatigue of ProTaper rotary nickel-titanium instruments in artificial canals with 2 different radii of curvature.

Ugur Inan1, Cumhur Aydin, Yasar M Tunca.   

Abstract

OBJECTIVE: This study compared the cyclic fatigue resistance of ProTaper rotary nickel-titanium (NiTi) files in artificial canals with 2 different radii of curvature. STUDY
DESIGN: One hundred ProTaper rotary instruments were used in this study. Twenty files of each size (S1, S2, F1, F2, and F3) were tested. Cyclic fatigue testing was performed using a device that allowed the instruments to rotate freely inside stainless steel artificial canals with radii of curvature of 5 and 10 mm. The number of cycles to fracture was recorded for each file and the data were analyzed using a t-test.
RESULTS: The 5-mm radius group had significantly fewer cycles to fracture than the 10-mm radius group for all file sizes. For sizes F2 and F3, the difference between the 5 and 10-mm radius groups was highly significant (P < .001). For the 10-mm group, the difference between S1 and F3 was significant (P < .05). For the more abrupt 5-mm radius group, the difference between S1-F2, S2-F2, and F1-F2 was statistically significant. The difference between S1-F3, S2-F3, and F1-F3 was highly significant (P < .001).
CONCLUSION: Cyclic fatigue resistance of ProTaper instruments was dependent on both instrument size and radius of curvature. Especially larger-size instruments should be used with great care in curved canals.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17904394     DOI: 10.1016/j.tripleo.2007.06.019

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  7 in total

1.  Influence of axial movement on fatigue of ProFile Ni-Ti rotary instruments: an in vitro evaluation.

Authors:  Marie-Chantal Avoaka; Youssef Haïkel
Journal:  Bosn J Basic Med Sci       Date:  2010-05       Impact factor: 3.363

2.  Electrochemical impedance spectroscopy investigation on the clinical lifetime of ProTaper rotary file system.

Authors:  Virgil Penta; Cristian Pirvu; Ioana Demetrescu
Journal:  Biomed Res Int       Date:  2014-01-29       Impact factor: 3.411

3.  Bending resistance and cyclic fatigue life of Reciproc Blue, WaveOne Gold, and Genius files in a double (S-shaped) curved canal.

Authors:  Taha Özyürek; Mustafa Gündoğar; Koray Yılmaz; Gülşah Uslu
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-12-13

4.  An in vitro comparison of cyclic fatigue resistance of ProTaper universal and GT series X files.

Authors:  Ramiro Montenegro-Santillán; Teresa Alegre-Domingo; Vicente Faus-Matoses; Vicente Faus-Llácer
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-05-01

5.  Failure of ProTaper rotary Ni-Ti instruments used by undergraduate students.

Authors:  Marc García-Font; Fernando Duran-Sindreu; Sergio Morello-Castro; Montserrat Mercade-Bellido; Rufino Bueno-Martínez; Miguel Roig-Cayón
Journal:  J Clin Exp Dent       Date:  2012-10-01

6.  The Effect of Autoclave Sterilization on Resistance to Cyclic Fatigue of Hero Endodontic File #642 (6%) at Two Artificial Curvature.

Authors:  Masoud Khabiri; Maziar Ebrahimi; Mohammad Reza Saei
Journal:  J Dent (Shiraz)       Date:  2017-12

7.  Evaluation of Cyclic Fatigue of Hyflex EDM, Twisted Files, and ProTaper Gold Manufactured with Different Processes: An In Vitro Study.

Authors:  Pooja D Khandagale; Prashant P Shetty; Saleem D Makandar; Pradeep A Bapna; Mohmed Isaqali Karobari; Anand Marya; Pietro Messina; Giuseppe Alessandro Scardina
Journal:  Int J Dent       Date:  2021-07-29
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.