Literature DB >> 17899224

Comparison of resin cement adhesion to Y-TZP ceramic following manufacturers' instructions of the cements only.

Mutlu Ozcan1, Sandra Kerkdijk, Luiz Felipe Valandro.   

Abstract

The objectives of this study were (1) to evaluate the bond strength of four resin materials with various chemical compositions following the manufacturers' instructions only and (2) to test their durability in dry and thermal aged conditions when they were bonded to zirconia ceramic. Four types of resin materials namely, Panavia F 2.0, Multilink, SuperBond and Quadrant Posterior Dense, were attached to the disc-shaped zirconia ceramics (LAVA, 3M ESPE) using polyethylene molds and polymerized accordingly after the ceramics were wet ground finished and ultrasonically cleaned. The specimens were randomly divided into two groups for ageing conditions. While the dry groups were tested immediately after attachment of the resin cement, the other specimens were subjected to thermocycling (x6,000, 5-55 degrees C). Bond strength results were significantly affected by the storage condition (p<0.001) and type of resin (p<0.001; analysis of variance). Panavia F 2.0 showed the highest bond strength results under dry conditions (9.6+/-4.1 MPa). When manufacturers' instructions of the resin cements were followed, no adhesion (0 MPa) was achieved on the zirconia after 6,000 thermal cyclings including Panavia F 2.0.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17899224     DOI: 10.1007/s00784-007-0151-y

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  13 in total

1.  Effect of different artificial aging conditions on ceramic-composite bond strength.

Authors:  Stefan Martin Wegner; Winnie Gerdes; Matthias Kern
Journal:  Int J Prosthodont       Date:  2002 May-Jun       Impact factor: 1.681

2.  Fatigue and damage tolerance of Y-TZP ceramics in layered biomechanical systems.

Authors:  Yu Zhang; Antonia Pajares; Brian R Lawn
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-10-15       Impact factor: 3.368

3.  Effect of conditioning methods on the microtensile bond strength of phosphate monomer-based cement on zirconia ceramic in dry and aged conditions.

Authors:  Regina Amaral; Mutlu Ozcan; Luiz Felipe Valandro; Ivan Balducci; Marco Antonio Bottino
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-04       Impact factor: 3.368

4.  Bond strength of a resin cement to high-alumina and zirconia-reinforced ceramics: the effect of surface conditioning.

Authors:  Luiz Felipe Valandro; Mutlu Ozcan; Marco Cícero Bottino; Marco Antonio Bottino; Roberto Scotti; Alvaro Della Bona
Journal:  J Adhes Dent       Date:  2006-06       Impact factor: 2.359

5.  Long-term resin bond strength to zirconia ceramic.

Authors:  S M Wegner; M Kern
Journal:  J Adhes Dent       Date:  2000       Impact factor: 2.359

6.  Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics.

Authors:  J Tinschert; D Zwez; R Marx; K J Anusavice
Journal:  J Dent       Date:  2000-09       Impact factor: 4.379

7.  Microtensile bond strength of a resin cement to glass infiltrated zirconia-reinforced ceramic: the effect of surface conditioning.

Authors:  Regina Amaral; Mutlu Ozcan; Marco Antonio Bottino; Luiz Felipe Valandro
Journal:  Dent Mater       Date:  2005-07-21       Impact factor: 5.304

8.  In vitro evaluation of shear bond strengths of resin to densely-sintered high-purity zirconium-oxide ceramic after long-term storage and thermal cycling.

Authors:  Markus B Blatz; Avishai Sadan; Javier Martin; Brien Lang
Journal:  J Prosthet Dent       Date:  2004-04       Impact factor: 3.426

Review 9.  An introduction to silanes and their clinical applications in dentistry.

Authors:  Jukka P Matinlinna; Lippo V J Lassila; Mutlu Ozcan; Antti Yli-Urpo; Pekka K Vallittu
Journal:  Int J Prosthodont       Date:  2004 Mar-Apr       Impact factor: 1.681

10.  Bonding to glass infiltrated alumina ceramic: adhesive methods and their durability.

Authors:  M Kern; V P Thompson
Journal:  J Prosthet Dent       Date:  1995-03       Impact factor: 3.426

View more
  18 in total

1.  The impact of cement mixing and storage errors on the risk of failure of glass-ceramic crowns.

Authors:  H Loher; M Behr; U Hintereder; M Rosentritt; G Handel
Journal:  Clin Oral Investig       Date:  2008-08-22       Impact factor: 3.573

2.  Precision of fit: zirconia three-unit fixed dental prostheses.

Authors:  Florian Beuer; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

3.  Evaluation of the topographical surface changes and roughness of zirconia after different surface treatments.

Authors:  Meryem Gülce Subaşı; Özgür İnan
Journal:  Lasers Med Sci       Date:  2011-07-24       Impact factor: 3.161

4.  Influence of surface treatments and resin cement selection on bonding to zirconia.

Authors:  Meryem Gülce Subaşı; Özgür Inan
Journal:  Lasers Med Sci       Date:  2012-11-09       Impact factor: 3.161

5.  Bond strength of resin cement to zirconia ceramic with different surface treatments.

Authors:  Aslıhan Usumez; Nermin Hamdemirci; Bilge Yuksel Koroglu; Irfan Simsek; Ozge Parlar; Tugrul Sari
Journal:  Lasers Med Sci       Date:  2012-06-21       Impact factor: 3.161

6.  Non-thermal plasma enhanced bonding of resin cement to zirconia ceramic.

Authors:  Tianshuang Liu; Liang Hong; Timothy Hottel; Xiaoqing Dong; Qingsong Yu; Meng Chen
Journal:  Clin Plasma Med       Date:  2016-08-27

7.  Marginal adaptation of three self-adhesive resin cements vs. a well-tried adhesive luting agent.

Authors:  M Behr; M Hansmann; M Rosentritt; G Handel
Journal:  Clin Oral Investig       Date:  2009-02-19       Impact factor: 3.573

8.  Fracture characteristics of anterior resin-bonded zirconia-fixed partial dentures.

Authors:  Martin Rosentritt; Stefan Ries; Carola Kolbeck; Maria Westphal; Ernst-Jürgen Richter; Gerhard Handel
Journal:  Clin Oral Investig       Date:  2009-02-17       Impact factor: 3.573

9.  On the interfacial fracture resistance of resin-bonded zirconia and glass-infiltrated graded zirconia.

Authors:  Herzl Chai; Marina Kaizer; Asima Chughtai; Hui Tong; Carina Tanaka; Yu Zhang
Journal:  Dent Mater       Date:  2015-09-11       Impact factor: 5.304

10.  Effect of surface treatment on the initial bond strength of different luting cements to zirconium oxide ceramic.

Authors:  F P Nothdurft; P J Motter; P R Pospiech
Journal:  Clin Oral Investig       Date:  2008-08-30       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.