Literature DB >> 16830664

Bond strength of a resin cement to high-alumina and zirconia-reinforced ceramics: the effect of surface conditioning.

Luiz Felipe Valandro1, Mutlu Ozcan, Marco Cícero Bottino, Marco Antonio Bottino, Roberto Scotti, Alvaro Della Bona.   

Abstract

PURPOSE: The aim of this study was to evaluate the effect of two surface conditioning methods on the microtensile bond strength of a resin cement to three high-strength core ceramics: high alumina-based (In-Ceram Alumina, Procera AllCeram) and zirconia-reinforced alumina-based (In-Ceram Zirconia) ceramics.
MATERIALS AND METHODS: Ten blocks (5 x 6 x 8 mm) of In-Ceram Alumina (AL), In-Ceram Zirconia (ZR), and Procera (PR) ceramics were fabricated according to each manufacturer's instructions and duplicated in composite. The specimens were assigned to one of the two following treatment conditions: (1) airborne particle abrasion with 110-microm Al2O3 particles + silanization, (2) silica coating with 30 microm SiOx particles (CoJet, 3M ESPE) + silanization. Each ceramic block was duplicated in composite resin (W3D-Master, Wilcos, Petrópolis, RJ, Brazil) using a mold made out of silicon impression material. Composite resin layers were incrementally condensed into the mold to fill up the mold and each layer was light polymerized for 40 s. The composite blocks were bonded to the surface-conditioned ceramic blocks using a resin cement system (Panavia F, Kuraray, Okayama, Japan). One composite resin block was fabricated for each ceramic block. The ceramic-composite was stored at 37 degrees C in distilled water for 7 days prior to bond tests. The blocks were cut under water cooling to produce bar specimens (n = 30) with a bonding area of approximately 0.6 mm2. The bond strength tests were performed in a universal testing machine (crosshead speed: 1 mm/min). Bond strength values were statistically analyzed using two-way ANOVA and Tukey's test (< or = 0.05).
RESULTS: Silica coating with silanization increased the bond strength significantly for all three high-strength ceramics (18.5 to 31.2 MPa) compared to that of airborne particle abrasion with 110-microm Al2O3 (12.7-17.3 MPa) (ANOVA, p < 0.05). PR exhibited the lowest bond strengths after both Al2O3 and silica coating (12.7 and 18.5 MPa, respectively).
CONCLUSION: Conditioning the high-strength ceramic surfaces with silica coating and silanization provided higher bond strengths of the resin cement than with airborne particle abrasion with 110-microm Al2O3 and silanization.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16830664

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  16 in total

1.  Early bond strength of two resin cements to Y-TZP ceramic using MPS or MPS/4-META silanes.

Authors:  Mutlu Özcan; Cenk Cura; Luiz Felipe Valandro
Journal:  Odontology       Date:  2011-01-27       Impact factor: 2.634

Review 2.  Adhesion/cementation to zirconia and other non-silicate ceramics: where are we now?

Authors:  Jeffrey Y Thompson; Brian R Stoner; Jeffrey R Piascik; Robert Smith
Journal:  Dent Mater       Date:  2010-11-20       Impact factor: 5.304

3.  The Impact of Plasma Treatment of Cercon® Zirconia Ceramics on Adhesion to Resin Composite Cements and Surface Properties.

Authors:  Kasra Tabari; Sepanta Hosseinpour; Hossein Mohammad-Rahimi
Journal:  J Lasers Med Sci       Date:  2017-08-29

4.  Bond strength of metal brackets bonded to a silica-based ceramic with light-cured adhesive : Influence of various surface treatment methods.

Authors:  Zhe-Chen Zhang; Yu-Fen Qian; Yi-Ming Yang; Qi-Ping Feng; Gang Shen
Journal:  J Orofac Orthop       Date:  2016-07-21       Impact factor: 1.938

5.  Comparison of resin cement adhesion to Y-TZP ceramic following manufacturers' instructions of the cements only.

Authors:  Mutlu Ozcan; Sandra Kerkdijk; Luiz Felipe Valandro
Journal:  Clin Oral Investig       Date:  2007-09-26       Impact factor: 3.573

6.  Surface modification for enhanced silanation of zirconia ceramics.

Authors:  J R Piascik; E J Swift; J Y Thompson; S Grego; B R Stoner
Journal:  Dent Mater       Date:  2009-04-18       Impact factor: 5.304

7.  The effect of CO2 and Nd:YAP lasers on CAD/CAM Ceramics: SEM, EDS and thermal studies.

Authors:  Ahmed El Gamal; Carlo Fornaini; Jean Paul Rocca; Omid H Muhammad; Etienne Medioni; Annamaria Cucinotta; Nathalie Brulat-Bouchard
Journal:  Laser Ther       Date:  2016-03-31

8.  Plasma in dentistry.

Authors:  Seunghee Cha; Young-Seok Park
Journal:  Clin Plasma Med       Date:  2014-05-10

9.  Shear Bond Strength of Zirconia Ceramic to Four Different Core Materials, An in vitro Study.

Authors:  Sara Tavakolizadeh; Mohamad Dehghan; Rahab Ghoveizi; Dmd MScD; Anahita Fayyazi
Journal:  J Dent (Shiraz)       Date:  2021-06

10.  Finite Element Analysis of IPS Empress II Ceramic Bridge Reinforced by Zirconia Bar.

Authors:  H Kermanshah; T Bitaraf; A Geramy
Journal:  J Dent (Tehran)       Date:  2012-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.