Literature DB >> 17881049

Diffusion of vitamin E in ultra-high molecular weight polyethylene.

Ebru Oral1, Keith K Wannomae, Shannon L Rowell, Orhun K Muratoglu.   

Abstract

Vitamin E-doped, radiation crosslinked ultra-high molecular weight polyethylene (UHMWPE) is developed as an alternate oxidation and wear resistant bearing surface in joint arthroplasty. We analyzed the diffusion behavior of vitamin E through UHMWPE and predicted penetration depth following doping with vitamin E and subsequent homogenization in inert gas used to penetrate implant components with vitamin E. Crosslinked UHMWPE (65- and 100-kGy irradiation) had higher activation energy and lower diffusion coefficients than uncrosslinked UHMWPE, but there were only slight differences in vitamin E profiles and penetration depth between the two doses. By using homogenization in inert gas below the melting point of the polymer following doping in pure vitamin E, the surface concentration of vitamin E was decreased and vitamin E stabilization was achieved throughout a desired thickness. We developed an analytical model based on Fickian theory that closely predicted vitamin E concentration as a function of depth following doping and homogenization.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17881049      PMCID: PMC2094214          DOI: 10.1016/j.biomaterials.2007.08.025

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  15 in total

1.  Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement. Ultra-high-molecular-weight polyethylene.

Authors:  A A Edidin; L Pruitt; C W Jewett; D J Crane; D Roberts; S M Kurtz
Journal:  J Arthroplasty       Date:  1999-08       Impact factor: 4.757

2.  The relationship between the clinical performance and large deformation mechanical behavior of retrieved UHMWPE tibial inserts.

Authors:  S M Kurtz; C M Rimnac; L Pruitt; C W Jewett; V Goldberg; A A Edidin
Journal:  Biomaterials       Date:  2000-02       Impact factor: 12.479

3.  Studies on the effect of electron beam radiation on the molecular structure of ultra-high molecular weight polyethylene under the influence of alpha-tocopherol with respect to its application in medical implants.

Authors:  M Parth; N Aust; K Lederer
Journal:  J Mater Sci Mater Med       Date:  2002-10       Impact factor: 3.896

4.  Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles.

Authors:  H G Willert; H Bertram; G H Buchhorn
Journal:  Clin Orthop Relat Res       Date:  1990-09       Impact factor: 4.176

5.  Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E.

Authors:  Ebru Oral; Steven D Christensen; Arnaz S Malhi; Keith K Wannomae; Orhun K Muratoglu
Journal:  J Arthroplasty       Date:  2006-06       Impact factor: 4.757

6.  The radiation improvement of polyethylene prostheses. A preliminary study.

Authors:  C J Grobbelaar; T A du Plessis; F Marais
Journal:  J Bone Joint Surg Br       Date:  1978-08

Review 7.  Protective role of vitamin E in biological systems.

Authors:  L Packer
Journal:  Am J Clin Nutr       Date:  1991-04       Impact factor: 7.045

8.  Osteolysis in alloarthroplasty of the hip. The role of bone cement fragmentation.

Authors:  H G Willert; H Bertram; G H Buchhorn
Journal:  Clin Orthop Relat Res       Date:  1990-09       Impact factor: 4.176

Review 9.  The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis.

Authors:  Georgios Digas; Johan Kärrholm; Jonas Thanner; Henrik Malchau; Peter Herberts
Journal:  Clin Orthop Relat Res       Date:  2004-12       Impact factor: 4.176

10.  Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE.

Authors:  Ebru Oral; Arnaz S Malhi; Orhun K Muratoglu
Journal:  Biomaterials       Date:  2005-08-18       Impact factor: 12.479

View more
  23 in total

1.  Second-generation annealed highly cross-linked polyethylene exhibits low wear.

Authors:  James A D'Antonio; William N Capello; Rama Ramakrishnan
Journal:  Clin Orthop Relat Res       Date:  2011-12-09       Impact factor: 4.176

2.  Elevated cytokine expression of different PEEK wear particles compared to UHMWPE in vivo.

Authors:  V Lorber; A C Paulus; A Buschmann; B Schmitt; T M Grupp; V Jansson; Sandra Utzschneider
Journal:  J Mater Sci Mater Med       Date:  2013-09-26       Impact factor: 3.896

3.  CORR Insights(®): Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.

Authors:  James A D'Antonio
Journal:  Clin Orthop Relat Res       Date:  2015-05-30       Impact factor: 4.176

Review 4.  Vitamin E diffused, highly crosslinked UHMWPE: a review.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Int Orthop       Date:  2010-12-01       Impact factor: 3.075

5.  A comparison of the efficacy of various antioxidants on the oxidative stability of irradiated polyethylene.

Authors:  Natalie Hope; Anuj Bellare
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

Review 6.  Vitamin E-stabilized UHMWPE for total joint implants: a review.

Authors:  Pierangiola Bracco; Ebru Oral
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

7.  Effect of cross-link density on the high pressure crystallization of UHMWPE.

Authors:  Ebru Oral; Christine Godleski-Beckos; Bassem W Ghali; Andrew J Lozynsky; Orhun K Muratoglu
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-08       Impact factor: 3.368

8.  Polyethylene oxidation in total hip arthroplasty: evolution and new advances.

Authors:  Enrique Gómez-Barrena; Francisco Medel; José Antonio Puértolas
Journal:  Open Orthop J       Date:  2009-12-24

Review 9.  Highly cross-linked polyethylene may not have an advantage in total knee arthroplasty.

Authors:  Vasileios I Sakellariou; Peter Sculco; Lazaros Poultsides; Timothy Wright; Thomas P Sculco
Journal:  HSS J       Date:  2013-08-10

10.  UHMWPE for arthroplasty: past or future?

Authors:  Elena Maria Brach Del Prever; Alessandro Bistolfi; Pierangiola Bracco; Luigi Costa
Journal:  J Orthop Traumatol       Date:  2008-12-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.