Literature DB >> 17879104

Heavy-ion conformal irradiation in the shallow-seated tumor therapy terminal at HIRFL.

Qiang Li1, Zhongying Dai, Zheng Yan, Xiaodong Jin, Xinguo Liu, Guoqing Xiao.   

Abstract

Basic research related to heavy-ion cancer therapy has been done at the Institute of Modern Physics (IMP), Chinese Academy of Sciences since 1995. Now a plan of clinical trial with heavy ions has been launched at IMP. First, superficially placed tumor treatment with heavy ions is expected in the therapy terminal at the Heavy Ion Research Facility in Lanzhou (HIRFL), where carbon ion beams with energy up to 100 MeV/u can be supplied. The shallow-seated tumor therapy terminal at HIRFL is equipped with a passive beam delivery system including two orthogonal dipole magnets, which continuously scan pencil beams laterally and generate a broad and uniform irradiation field, a motor-driven energy degrader and a multi-leaf collimator. Two different types of range modulator, ripple filter and ridge filter with which Guassian-shaped physical dose and uniform biological effective dose Bragg peaks can be shaped for therapeutic ion beams respectively, have been designed and manufactured. Therefore, two-dimensional and three-dimensional conformal irradiations to tumors can be performed with the passive beam delivery system at the earlier therapy terminal. Both the conformal irradiation methods have been verified experimentally and carbon-ion conformal irradiations to patients with superficially placed tumors have been carried out at HIRFL since November 2006.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17879104     DOI: 10.1007/s11517-007-0245-3

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  Design and construction of a ripple filter for a smoothed depth dose distribution in conformal particle therapy.

Authors:  U Weber; G Kraft
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

2.  Ridge filter design and optimization for the broad-beam three-dimensional irradiation system for heavy-ion radiotherapy.

Authors:  B Schaffner; T Kanai; Y Futami; M Shimbo; E Urakabe
Journal:  Med Phys       Date:  2000-04       Impact factor: 4.071

3.  Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy.

Authors:  T Kanai; M Endo; S Minohara; N Miyahara; H Koyama-ito; H Tomura; N Matsufuji; Y Futami; A Fukumura; T Hiraoka; Y Furusawa; K Ando; M Suzuki; F Soga; K Kawachi
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-04-01       Impact factor: 7.038

4.  The 200-MeV proton therapy project at the Paul Scherrer Institute: conceptual design and practical realization.

Authors:  E Pedroni; R Bacher; H Blattmann; T Böhringer; A Coray; A Lomax; S Lin; G Munkel; S Scheib; U Schneider
Journal:  Med Phys       Date:  1995-01       Impact factor: 4.071

5.  Broad beam three-dimensional irradiation for proton radiotherapy.

Authors:  T Kanai; K Kawachi; H Matsuzawa; T Inada
Journal:  Med Phys       Date:  1983 May-Jun       Impact factor: 4.071

6.  Commissioning of a conformal irradiation system for heavy-ion radiotherapy using a layer-stacking method.

Authors:  Tatsuaki Kanai; Nobuyuki Kanematsu; Shinichi Minohara; Masataka Komori; Masami Torikoshi; Hiroshi Asakura; Noritoshi Ikeda; Takayuki Uno; Yuka Takei
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

  6 in total
  4 in total

1.  World Congress on Medical Physics and Biomedical Engineering (WC2006, Seoul).

Authors:  Eung Je Woo; Hee-Joung Kim; Jos A E Spaan
Journal:  Med Biol Eng Comput       Date:  2007-11-15       Impact factor: 2.602

Review 2.  Charged particles in radiation oncology.

Authors:  Marco Durante; Jay S Loeffler
Journal:  Nat Rev Clin Oncol       Date:  2009-12-01       Impact factor: 66.675

Review 3.  Flourish of Proton and Carbon Ion Radiotherapy in China.

Authors:  Yue Li; Xiaoman Li; Jiancheng Yang; Sicheng Wang; Meitang Tang; Jiawen Xia; Yunzhe Gao
Journal:  Front Oncol       Date:  2022-02-14       Impact factor: 6.244

Review 4.  Effects of space flight on sperm function and integrity: A systematic review.

Authors:  Khulood Ahrari; Temidayo S Omolaoye; Nandu Goswami; Hanan Alsuwaidi; Stefan S du Plessis
Journal:  Front Physiol       Date:  2022-08-11       Impact factor: 4.755

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.