Ridge filter design and optimization for the broad-beam three-dimensional irradiation system for heavy-ion radiotherapy.

B Schaffner1, T Kanai, Y Futami, M Shimbo, E Urakabe.   

Abstract

The broad-beam three-dimensional irradiation system under development at National Institute of Radiological Sciences (NIRS) requires a small ridge filter to spread the initially monoenergetic heavy-ion beam to a small spread-out Bragg peak (SOBP). A large SOBP covering the target volume is then achieved by a superposition of differently weighted and displaced small SOBPs. Two approaches were studied for the definition of a suitable ridge filter and experimental verifications were performed. Both approaches show a good agreement between the calculated and measured dose and lead to a good homogeneity of the biological dose in the target. However, the ridge filter design that produces a Gaussian-shaped spectrum of the particle ranges was found to be more robust to small errors and uncertainties in the beam application. Furthermore, an optimization procedure for two fields was applied to compensate for the missing dose from the fragmentation tail for the case of a simple-geometry target. The optimized biological dose distributions show that a very good homogeneity is achievable in the target.

Mesh:

Substances:

Year:  2000        PMID: 10798694     DOI: 10.1118/1.598934

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Ultra-high dose rate radiation production and delivery systems intended for FLASH.

Authors:  Jonathan Farr; Veljko Grilj; Victor Malka; Srinivasan Sudharsan; Marco Schippers
Journal:  Med Phys       Date:  2022-05-05       Impact factor: 4.506

2.  Heavy-ion conformal irradiation in the shallow-seated tumor therapy terminal at HIRFL.

Authors:  Qiang Li; Zhongying Dai; Zheng Yan; Xiaodong Jin; Xinguo Liu; Guoqing Xiao
Journal:  Med Biol Eng Comput       Date:  2007-09-19       Impact factor: 2.602

3.  Synchrotron-Based Pencil Beam Scanning Nozzle with an Integrated Mini-Ridge Filter: A Dosimetric Study to Optimize Treatment Delivery.

Authors:  Xianliang Wang; Yupeng Li; Xiaodong Zhang; Heng Li; Koichi Miyazaki; Rintaro Fujimoto; Hiroshi Akiyama; Michael T Gillin; Falk Poenisch; Narayan Sahoo; David Grosshans; Brandon Gunn; Steven Jay Frank; Pei Wang; Jinyi Lang; Qing Hou; Xiaorong Ronald Zhu
Journal:  Cancers (Basel)       Date:  2017-12-13       Impact factor: 6.639

4.  Carbon-ion pencil beam scanning for thoracic treatment - initiation report and dose metrics evaluation.

Authors:  Masataka Karube; Shinichiro Mori; Hiroshi Tsuji; Naoyoshi Yamamoto; Mio Nakajima; Keiichi Nakagawa; Tadashi Kamada
Journal:  J Radiat Res       Date:  2016-07-05       Impact factor: 2.724

5.  Quantitative analysis of treatments using real-time image gated spot-scanning with synchrotron-based proton beam therapy system log data.

Authors:  Takaaki Yoshimura; Shinichi Shimizu; Takayuki Hashimoto; Kentaro Nishioka; Norio Katoh; Hiroshi Taguchi; Koichi Yasuda; Taeko Matsuura; Seishin Takao; Masaya Tamura; Sodai Tanaka; Yoichi M Ito; Yuto Matsuo; Hiroshi Tamura; Kenji Horita; Kikuo Umegaki; Hiroki Shirato
Journal:  J Appl Clin Med Phys       Date:  2020-11-05       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.