In vivo evaluation of ProPex electronic apex locator.

Ebru Ozsezer1, Ugur Inan, Ugur Aydin.   

Abstract

The aim of this in vivo study was to evaluate the performance of ProPex apex locator after extirpation and in presence of different irrigation solutions: 2.5% NaOCl, 0.9% NaCl, and 0.2% chlorhexidine gluconate solutions. Twenty-seven single-rooted human teeth scheduled for extraction with mature apices were selected for this study. Measurements were performed by using ProPex after extirpation and in presence of the irrigation solutions. After extraction of the teeth, a stereomicroscope was used to confirm visually the relationship of the tip of the endodontic file to the apical foramen, and actual lengths (ALs) were determined by reducing 0.5 mm from these lengths. The data were statistically analyzed with cluster analysis. The results of this study showed that measurements after extirpation had the smallest distance to the ALs. Among the irrigation solution groups, chlorhexidine gluconate group had the smallest distance to the ALs, whereas saline group had the greatest. Most accurate measurements were obtained after extirpation.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17878086     DOI: 10.1016/j.joen.2007.04.003

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  10 in total

1.  Comparison of two electronic apex locators on human cadavers.

Authors:  Luca Marigo; Gian Luca Gervasi; Francesco Somma; Giuseppe Squeo; Raffaella Castagnola
Journal:  Clin Oral Investig       Date:  2015-11-04       Impact factor: 3.573

2.  Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  Saru Jain; Ravi Kapur
Journal:  Contemp Clin Dent       Date:  2012-09

3.  A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study.

Authors:  Irfana Khursheed; Ruchika Bansal; Tajinder Bansal; Harkanwal Preet Singh; Madhulika Yadav; K Jetender Reddy
Journal:  Dent Res J (Isfahan)       Date:  2014-01

4.  Comparative Evaluation of Accuracy of Two Electronic Apex Locators in the Presence of Contemporary Irrigants: An In vitro Study.

Authors:  Queentaj Baruah; Nidhi Sinha; Bijay Singh; P Narendranatha Reddy; Kaveri Baruah; Vaishak Augustine
Journal:  J Int Soc Prev Community Dent       Date:  2018-07-18

5.  Ex Vivo Evaluation of the Accuracy of 3 Electronic Apex Locators in Different Environments: A Micro-Computed Tomography Study.

Authors:  Firdevs Çınar; Yakup Üstün
Journal:  Eur Endod J       Date:  2020-12

6.  In vitro detection of simulated apical root perforation with two electronic apex locators.

Authors:  Kiumars Nazari Moghaddam; Shahrzad Nazari; Leila Shakeri; Kiamars Honardar; Farshid Mirmotalebi
Journal:  Iran Endod J       Date:  2010-02-20

7.  An in vitro stereomicroscopic comparative evaluation of a combination of apex locator and endodontic motor with an integrated endodontic motor.

Authors:  Ch Swarupa; Girija S Sajjan; Yv Sashi Kanth
Journal:  J Conserv Dent       Date:  2013-09

8.  Effects of dissolving solutions on the accuracy of an electronic apex locator-integrated endodontic handpiece.

Authors:  Yakup Ustun; Ozgur Uzun; Ozgur Er; Murat Maden; Fatma Yalpı; Burhan Can Canakci
Journal:  ScientificWorldJournal       Date:  2013-11-26

9.  The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators.

Authors:  Ewa Marek; Ryta Łagocka; Katarzyna Kot; Krzysztof Woźniak; Mariusz Lipski
Journal:  BMC Oral Health       Date:  2019-12-31       Impact factor: 2.757

10.  A Comparative Evaluation of Efficacy of Electronic Apex Locator, Digital Radiography, and Conventional Radiographic Method for Root Canal Working Length Determination in Primary Teeth: An In Vitro Study.

Authors:  Anchal Sahni; Rishabh Kapoor; Kapil Gandhi; Dipanshu Kumar; Geetika Datta; Ritika Malhotra
Journal:  Int J Clin Pediatr Dent       Date:  2020 Sep-Oct
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.