Literature DB >> 17876243

The Leksell Gamma Knife Perfexion and comparisons with its predecessors.

Christer Lindquist1, Ian Paddick.   

Abstract

OBJECTIVE: The objective of this study is to introduce a new radiosurgical device, the Leksell Gamma Knife Perfexion (Elekta Instruments AB, Stockholm, Sweden). Design and performance characteristics are compared with previous models of the gamma knife in a clinical setting.
METHODS: Performance-related features in the design of the new radiosurgical system are described, and the ability to create complex shapes of isodose volumes even with a single isocenter is demonstrated. The concept of "dynamic shaping" of dose distribution is introduced as a means of decreasing the exposure to structures outside the target. Dose plans for the Leksell Gamma Knife Models B, 4C, and Perfexion have been created for target pathologies to illustrate how the software and hardware of the new radiosurgical system can increase treatment quality, decrease treatment time, and increase patient comfort. Radiation doses to critical organs in the rest of the human body are compared.
RESULTS: The automated collimator arrangement in the Perfexion makes it possible to produce more complex treatment volumes than with previous models of the gamma knife. This results from the enhanced ability to shape isodose volumes, even for single isocenters. The collimator arrangement and the patient positioning system also allow shorter patient transit times, reducing unwanted radiation exposure during movement between isocenters.
CONCLUSION: The Perfexion exceeds the capabilities of previous gamma knife models in terms of treatment efficiency, conformity, and radiation protection. These qualities enable treatment of larger target volumes, especially close to eloquent areas. Pathologies previously inaccessible in the head and neck are now treatable due to the increased volume of the radiation cavity.

Entities:  

Mesh:

Year:  2007        PMID: 17876243     DOI: 10.1227/01.neu.0000289726.35330.8a

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  21 in total

1.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.

Authors:  David M Klein; Ramesh C Tailor; Louis Archambault; Lilie Wang; Francois Therriault-Proulx; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Stereotactic Radiosurgery with the CyberKnife for Pituitary Adenomas.

Authors:  L Dade Lunsford
Journal:  J Korean Neurosurg Soc       Date:  2009-06-30

Review 3.  The Role of Surgery in Meningiomas.

Authors:  Michele Bailo; Filippo Gagliardi; Nicola Boari; Antonella Castellano; Alfio Spina; Pietro Mortini
Journal:  Curr Treat Options Neurol       Date:  2019-09-27       Impact factor: 3.598

4.  A technique for achieving submillimeter accuracy of volume-staged stereotactic radiosurgery.

Authors:  Lijun Ma; Shannon Fogh; Nalin Gupta; Andrew Hwang; Dilini Pinnaduwage; Jean Nakamura; Igor Barani; Michael McDermott; Penny K Sneed; David A Larson; Arjun Sahgal
Journal:  J Radiosurg SBRT       Date:  2012

5.  Impact of decaying dose rate in gamma knife radiosurgery: in vitro study on 9L rat gliosarcoma cells.

Authors:  Ajay Niranjan; Glenn Gobbel; Josef Novotny; Jagdish Bhatnagar; Wendy Fellows; L Dade Lunsford
Journal:  J Radiosurg SBRT       Date:  2012

6.  Spatial shifts in frame-based Gamma Knife radiosurgery: A case for cone beam CT imaging as quality assurance using the Gamma Knife® Icon™.

Authors:  M Sean Peach; Daniel M Trifiletti; Sunil W Dutta; James M Larner; David J Schlesinger; Jason P Sheehan
Journal:  J Radiosurg SBRT       Date:  2018

7.  Target and peripheral dose from radiation sector motions accompanying couch repositioning of patient coordinates with the Gamma Knife(®) Perfexion(™).

Authors:  Tuan-Anh Tran; Vincent Wu; Harish Malhotra; James P Steinman; Dheerendra Prasad; Matthew B Podgorsak
Journal:  Radiol Oncol       Date:  2011-04-23       Impact factor: 2.991

8.  First year experience with newly developed Leksell Gamma Knife Perfexion.

Authors:  Jagdish P Bhatnagar; Josef Novotny; Ajay Niranjan; Douglas Kondziolka; John Flickinger; Dade Lunsford; M Saiful Huq
Journal:  J Med Phys       Date:  2009-07

9.  The role of radiation therapy in the management of metastatic melanoma in the brain.

Authors:  Angela Hong; Gerald Fogarty; Michael A Izard
Journal:  Int J Surg Oncol       Date:  2012-04-11

10.  Initial clinical experience with frameless optically guided stereotactic radiosurgery/radiotherapy in pediatric patients.

Authors:  Sassan Keshavarzi; Hal Meltzer; Sharona Ben-Haim; Charles Benjamin Newman; Joshua D Lawson; Michael L Levy; Kevin Murphy
Journal:  Childs Nerv Syst       Date:  2009-03-27       Impact factor: 1.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.