In vivo biomechanical assessment of triglycidylamine crosslinked pericardium.

Michael S Sacks1, Hirotsugu Hamamoto, Jeanne M Connolly, Robert C Gorman, Joseph H Gorman, Robert J Levy.   

Abstract

While glutaraldehyde crosslinking is most often used to fabricate bioprosthetic heart valves (BHV) using heterograft tissues, it predisposes BHV to calcification and dramatically stiffens the heterograft tissues. Our group previously reported the synthesis and characterization of a novel epoxy-crosslinker, triglycidylamine (TGA). TGA pretreatment of BHV tissues compared to glutaraldehyde results in both calcification resistance in subdermal implants and improved leaflet compliance. In these prior studies, optimal calcification inhibition was noted with the combined use of TGA with mercapto-aminobisphosphonate (MABP). In the present study, we investigated the hypothesis that bovine pericardium cross-linked with TGA-MABP retains these beneficial biomechanical properties in vivo using a novel mitral valve anterior leaflet (MVAL) ovine valvuloplasty model. Bovine pericardial specimens were crosslinked with either glutaraldehyde or TGA-MABP, from which 1cm2 sections were implanted in the ovine MVAL after removal of the original tissue of the same size. An array of four sonomicrometry transducers were implanted on the corners and used to compute the complete in-surface strain tensor cardiac cycle over the cardiac cycle at 0 and 4 weeks. Following explant samples were fixed in formalin for histology studies. At 4 weeks both treatment groups experienced no dimensional changes in the unloaded state, indicating no shrinkage. When fully loaded during peak systolic ejection, TGA-MABP valvuloplasty patches were significantly more compliant, which did not change at 4 weeks. In contrast, the glutaraldehyde areal strain increased significantly by 4 weeks. Estimated implant stresses for both treatment groups, based on previously measured biomechanical properties [Connolly JM, Alferiev I, Clark-Gruel JN, Eidelman N, Sacks M, Palmatory E, et al. Triglycidylamine crosslinking of porcine aortic valve cusps or bovine pericardium results in improved biocompatibility, biomechanics, and calcification resistance: chemical and biological mechanisms. Am J Pathol 2005;166(1):1-13], were 40 and 250 kPa in the circumferential and radial directions, respectively, which are comparable to predicted BHV peak stress levels. We conclude that TGA-MABP crosslinked bovine pericardium, when subjected to in vivo BHV stress levels in a blood-contacting environment, maintains stable functionality.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17822757      PMCID: PMC2094135          DOI: 10.1016/j.biomaterials.2007.08.021

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  28 in total

1.  Biaxial mechanical properties of the native and glutaraldehyde-treated aortic valve cusp: Part II--A structural constitutive model.

Authors:  K L Billiar; M S Sacks
Journal:  J Biomech Eng       Date:  2000-08       Impact factor: 2.097

Review 2.  The influence of design on bioprosthetic valve durability.

Authors:  I Vesely
Journal:  J Long Term Eff Med Implants       Date:  2001

3.  Characteristics of compressive strains in porcine aortic valves cusps.

Authors:  Margaret M Adamczyk; Ivan Vesely
Journal:  J Heart Valve Dis       Date:  2002-01

4.  Editorial: Are immune mechanisms important in tissue heart valve failure? A debate.

Authors:  F J Schoen
Journal:  J Heart Valve Dis       Date:  2001-07

5.  Effects of fixation pressure on the biaxial mechanical behavior of porcine bioprosthetic heart valves with long-term cyclic loading.

Authors:  Sarah M Wells; Michael S Sacks
Journal:  Biomaterials       Date:  2002-06       Impact factor: 12.479

6.  In-vivo dynamic deformation of the mitral valve anterior leaflet.

Authors:  Michael S Sacks; Yoshiharu Enomoto; Jeffrey R Graybill; W David Merryman; Ahmad Zeeshan; Ajit P Yoganathan; Robert J Levy; Robert C Gorman; Joseph H Gorman
Journal:  Ann Thorac Surg       Date:  2006-10       Impact factor: 4.330

Review 7.  Heart valve function: a biomechanical perspective.

Authors:  Michael S Sacks; Ajit P Yoganathan
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2007-08-29       Impact factor: 6.237

8.  Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp--Part I: Experimental results.

Authors:  K L Billiar; M S Sacks
Journal:  J Biomech Eng       Date:  2000-02       Impact factor: 2.097

9.  Structural changes in porcine bioprosthetic valves of a left ventricular assist system in human patients.

Authors:  M Moczar; R Houël; M Ginat; V Clérin; D Wheeldon; D Loisance
Journal:  J Heart Valve Dis       Date:  2000-01

10.  Mechanisms of the in vivo inhibition of calcification of bioprosthetic porcine aortic valve cusps and aortic wall with triglycidylamine/mercapto bisphosphonate.

Authors:  H Scott Rapoport; Jeanne M Connolly; James Fulmer; Ning Dai; Brandon H Murti; Robert C Gorman; Joseph H Gorman; Ivan Alferiev; Robert J Levy
Journal:  Biomaterials       Date:  2006-10-06       Impact factor: 12.479

View more
  9 in total

1.  A generalized method for the analysis of planar biaxial mechanical data using tethered testing configurations.

Authors:  Will Zhang; Yuan Feng; Chung-Hao Lee; Kristen L Billiar; Michael S Sacks
Journal:  J Biomech Eng       Date:  2015-04-15       Impact factor: 2.097

2.  Shrinkage temperature and anti-calcification property of triglycidylamine-crosslinked autologous tissue.

Authors:  Masataka Sato; Yuji Hiramatsu; Shonosuke Matsushita; Shoko Sato; Yasunori Watanabe; Yuzuru Sakakibara
Journal:  J Artif Organs       Date:  2014-05-04       Impact factor: 1.731

3.  On the in vivo deformation of the mitral valve anterior leaflet: effects of annular geometry and referential configuration.

Authors:  Rouzbeh Amini; Chad E Eckert; Kevin Koomalsingh; Jeremy McGarvey; Masahito Minakawa; Joseph H Gorman; Robert C Gorman; Michael S Sacks
Journal:  Ann Biomed Eng       Date:  2012-02-11       Impact factor: 3.934

4.  Effects of cyclic flexural fatigue on porcine bioprosthetic heart valve heterograft biomaterials.

Authors:  Ali Mirnajafi; Brett Zubiate; Michael S Sacks
Journal:  J Biomed Mater Res A       Date:  2010-07       Impact factor: 4.396

5.  In vivo dynamic deformation of the mitral valve annulus.

Authors:  Chad E Eckert; Brett Zubiate; Mathieu Vergnat; Joseph H Gorman; Robert C Gorman; Michael S Sacks
Journal:  Ann Biomed Eng       Date:  2009-07-08       Impact factor: 3.934

6.  Effects of Leaflet Stiffness on In Vitro Dynamic Bioprosthetic Heart Valve Leaflet Shape.

Authors:  Hiroatsu Sugimoto; Michael S Sacks
Journal:  Cardiovasc Eng Technol       Date:  2013-03       Impact factor: 2.495

7.  An inverse modeling approach for stress estimation in mitral valve anterior leaflet valvuloplasty for in-vivo valvular biomaterial assessment.

Authors:  Chung-Hao Lee; Rouzbeh Amini; Robert C Gorman; Joseph H Gorman; Michael S Sacks
Journal:  J Biomech       Date:  2013-11-08       Impact factor: 2.712

8.  Polyphenol-stabilized tubular elastin scaffolds for tissue engineered vascular grafts.

Authors:  Ting-Hsien Chuang; Christopher Stabler; Agneta Simionescu; Dan T Simionescu
Journal:  Tissue Eng Part A       Date:  2009-10       Impact factor: 4.080

Review 9.  ECM-based materials in cardiovascular applications: Inherent healing potential and augmentation of native regenerative processes.

Authors:  Anna V Piterina; Aidan J Cloonan; Claire L Meaney; Laura M Davis; Anthony Callanan; Michael T Walsh; Tim M McGloughlin
Journal:  Int J Mol Sci       Date:  2009-11-20       Impact factor: 6.208

  9 in total