In-vivo dynamic deformation of the mitral valve anterior leaflet.

Michael S Sacks1, Yoshiharu Enomoto, Jeffrey R Graybill, W David Merryman, Ahmad Zeeshan, Ajit P Yoganathan, Robert J Levy, Robert C Gorman, Joseph H Gorman.   

Abstract

BACKGROUND: Surgical techniques have been developed for mitral valve repair for a wide range of pathologies. However, excessive tissue stress and damage have been identified as etiologic factors limiting long-term durability. Before computational models to optimize valve repair can be realistically developed, in-vivo dynamic mitral valve leaflet strain data are required. However, these data do not presently exist. In the present study, a sheep model and sonomicrometry were used to compute the in-surface Eulerian strain tensor of the anterior leaflet over the cardiac cycle at varying afterloads.
METHODS: The anterior leaflet of nine Dorsett sheep (35 kg to 45 kg) was instrumented with nine 1-mm hemispherical piezoelectric transducers in a 15-mm square array. Three-dimensional crystal spatial positions were recorded at 250 Hz over several cardiac cycles, with peak left ventricular pressures varying from 90 mm Hg to 200 mm Hg. The in-surface Eulerian strain tensor was computed from the crystal displacements.
RESULTS: The mitral valve anterior leaflet experiences large anisotropic strains and peak strain rates of 400%/s, followed by an absolute cessation of any deformation during systole. Increasing left ventricular pressure also increased the effective leaflet stiffness but not the peak strains.
CONCLUSIONS: We report the first data on the dynamic in-vivo strain tensor of a functioning mitral valve anterior leaflet, which indicated large anisotropic strains and very high strain rates. Our observations also suggest that changes in left ventricular pressure and annular geometry result in altered effective leaflet stiffness, and may be an important factor in reducing leaflet stress and as such potentially affect mitral valve repair longevity.

Entities:  

Mesh:

Year:  2006        PMID: 16996935     DOI: 10.1016/j.athoracsur.2006.03.117

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  53 in total

1.  Development of a semi-automated method for mitral valve modeling with medial axis representation using 3D ultrasound.

Authors:  Alison M Pouch; Paul A Yushkevich; Benjamin M Jackson; Arminder S Jassar; Mathieu Vergnat; Joseph H Gorman; Robert C Gorman; Chandra M Sehgal
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Characterization of CD133 Antibody-Directed Recellularized Heart Valves.

Authors:  J Koudy Williams; Elizabeth S Miller; Magan R Lane; Anthony Atala; James J Yoo; James E Jordan
Journal:  J Cardiovasc Transl Res       Date:  2015-09-04       Impact factor: 4.132

3.  How do annuloplasty rings affect mitral leaflet dynamic motion?

Authors:  Wolfgang Bothe; John-Peder Escobar Kvitting; Julia C Swanson; Serdar Göktepe; Kathy N Vo; Neil B Ingels; D Craig Miller
Journal:  Eur J Cardiothorac Surg       Date:  2010-03-23       Impact factor: 4.191

Review 4.  Heart valve function: a biomechanical perspective.

Authors:  Michael S Sacks; Ajit P Yoganathan
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2007-08-29       Impact factor: 6.237

5.  Material properties of the ovine mitral valve anterior leaflet in vivo from inverse finite element analysis.

Authors:  Gaurav Krishnamurthy; Daniel B Ennis; Akinobu Itoh; Wolfgang Bothe; Julia C Swanson; Matts Karlsson; Ellen Kuhl; D Craig Miller; Neil B Ingels
Journal:  Am J Physiol Heart Circ Physiol       Date:  2008-07-11       Impact factor: 4.733

6.  The effect of physiological stretch and the valvular endothelium on mitral valve proteomes.

Authors:  Mir S Ali; Xinmei Wang; Carla Mr Lacerda
Journal:  Exp Biol Med (Maywood)       Date:  2019-02-05

Review 7.  Heart Valve Biomechanics and Underlying Mechanobiology.

Authors:  Salma Ayoub; Giovanni Ferrari; Robert C Gorman; Joseph H Gorman; Frederick J Schoen; Michael S Sacks
Journal:  Compr Physiol       Date:  2016-09-15       Impact factor: 9.090

Review 8.  Computational modeling of cardiac valve function and intervention.

Authors:  Wei Sun; Caitlin Martin; Thuy Pham
Journal:  Annu Rev Biomed Eng       Date:  2014-04-16       Impact factor: 9.590

9.  In vivo biomechanical assessment of triglycidylamine crosslinked pericardium.

Authors:  Michael S Sacks; Hirotsugu Hamamoto; Jeanne M Connolly; Robert C Gorman; Joseph H Gorman; Robert J Levy
Journal:  Biomaterials       Date:  2007-09-05       Impact factor: 12.479

Review 10.  Fibrous scaffolds for building hearts and heart parts.

Authors:  A K Capulli; L A MacQueen; Sean P Sheehy; K K Parker
Journal:  Adv Drug Deliv Rev       Date:  2015-12-04       Impact factor: 15.470

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.