Durability improvement of polymer chamber of pulsatile extracorporeal life support system in terms of mechanical change.

Hyuk Choi1, Seung Hoon Paik, Kwang Ho Lee, Byoung Goo Min, Yong Soon Won.   

Abstract

Twin Pulse Life Support, T-PLS has received the CE mark (2003) and Korea Food and Drug Administration (KFDA) approval (2004) for short-term application as an Extracorporeal Life Support system (ECLS). T-PLS's original intention was to apply for not only short-term but also long-term application such as Extracorporeal ventricular assist device (VAD). Hence, a long-term durability test was conducted. The 1-year reliability of the systems tested in this study did not meet the STS/ASAIO standard of 80% reliability with 60% confidence for a 1-year mission life. However, without the disposable units, which are only designed to operate for 6 h, the 1-year reliability exceeded the STS/ASAIO standard of 80% reliability with 60% confidence. In this study, by using the existing analysis methods and analyzing the root cause of the failure used by a numerical analysis. As eliminating or mitigating of the root cause of the failure, we improved the durability of blood chamber and evaluated the performance of the modified system via the hemolysis test.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17721715     DOI: 10.1007/s11517-007-0215-9

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   3.079


  27 in total

1.  Vacuum assisted cardiopulmonary bypass in minimally invasive cardiac surgery: its feasibility and effects on hemolysis.

Authors:  H Shin; R Yozu; T Maehara; T Matayoshi; M Morita; Y Kawai; T Yamada; S Kawada
Journal:  Artif Organs       Date:  2000-06       Impact factor: 3.094

2.  Durability testing of a completely implantable electric total artificial heart.

Authors:  Conrad M Zapanta; Alan J Snyder; William J Weiss; Thomas J Cleary; John D Reibson; Marjorie A Rawhouser; Jeffrey P Lewis; William S Pierce; Gerson Rosenberg
Journal:  ASAIO J       Date:  2005 May-Jun       Impact factor: 2.872

3.  Design of a hydraulic analog of the circulatory system for evaluating artificial hearts.

Authors:  F M Donovan
Journal:  Biomater Med Devices Artif Organs       Date:  1975

4.  Methods for measuring plasma hemoglobin in micromolar concentration compared.

Authors:  V F Fairbanks; S C Ziesmer; P C O'Brien
Journal:  Clin Chem       Date:  1992-01       Impact factor: 8.327

5.  The hemolysis test of the Gyro C1E3 pump in pulsatile mode.

Authors:  E Tayama; T Nakazawa; Y Takami; K Makinouchi; S Ohtsubo; Y Ohashi; A J Andrade; J Glueck; J Mueller; Y Nosé
Journal:  Artif Organs       Date:  1997-07       Impact factor: 3.094

6.  In vitro and in vivo testing of a totally implantable left ventricular assist system.

Authors:  J S Jassawalla; M A Daniel; H Chen; J Lee; D LaForge; J Billich; N Ramasamy; P J Miller; P E Oyer; P M Portner
Journal:  ASAIO Trans       Date:  1988 Jul-Sep

7.  Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation.

Authors:  A Sezai; M Shiono; Y Orime; K Nakata; M Hata; M Iida; S Kashiwazaki; J Kinoshita; M Nemoto; T Koujima; M Furuichi; K Eda; H Hirose; T Yoshino; A Saitoh; Y Taniguchi; Y Sezai
Journal:  Artif Organs       Date:  1999-03       Impact factor: 3.094

8.  Direct detection of red blood cell fragments: a new flow cytometric method to evaluate hemolysis in blood pumps.

Authors:  J Linneweber; T W Chow; T Takano; T Maeda; K Nonaka; S Schulte-Eistrup; S Kawahito; O Elert; J L Moake; Y Nosé
Journal:  ASAIO J       Date:  2001 Sep-Oct       Impact factor: 2.872

9.  Jostra Rota Flow RF-30 pump system: a new centrifugal blood pump for cardiopulmonary bypass.

Authors:  Y Orime; M Shiono; S Yagi; T Yamamoto; H Okumura; K Nakata; S Kimura; M Hata; A Sezai; S Kashiwazaki; S Choh; N Negishi; Y Sezai; T Matsui; M Suzuki
Journal:  Artif Organs       Date:  2000-06       Impact factor: 3.094

10.  Hemolysis test of a centrifugal pump in a pulsatile mode: the effect of pulse rate and RPM variance.

Authors:  E Tayama; Y Niimi; Y Takami; Y Ohashi; G Ohtsuka; J A Glueck; J Mueller; Y Nosé
Journal:  Artif Organs       Date:  1997-12       Impact factor: 3.094

View more
  1 in total

1.  World Congress on Medical Physics and Biomedical Engineering (WC2006, Seoul).

Authors:  Eung Je Woo; Hee-Joung Kim; Jos A E Spaan
Journal:  Med Biol Eng Comput       Date:  2007-11-15       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.