Jostra Rota Flow RF-30 pump system: a new centrifugal blood pump for cardiopulmonary bypass.

Y Orime1, M Shiono, S Yagi, T Yamamoto, H Okumura, K Nakata, S Kimura, M Hata, A Sezai, S Kashiwazaki, S Choh, N Negishi, Y Sezai, T Matsui, M Suzuki.   

Abstract

The Rota Flow pump is a fully integrated centrifugal pump system in the Jostra heart-lung machine HL-20 with features such as a less friction mono-pivot bearing system, sealless pump housing, and spiral housing. To evaluate its biocompatibility, antithrombogenesity, and hemolysis, we used it as a main pump of cardiopulmonary bypass (CPB) in coronary artery bypass grafting (CABG) cases and compared it with the BioMedicus pump. From February 1999 to May 1999, 30 consecutive patients underwent CABG under conventional CPB. Fifteen cases were supported by the Rota Flow RF-32 (Group R), and the remaining 15 were pumped by the BioMedicus BP-80 (Group B). In both groups, the flow rate was controlled in an equivalent value. Blood sampling was as follows: preoperative, 60 min after, postoperative Days (POD) 0, 1, and 2. We evaluated the plasma free hemoglobin (fHb) as the hemolysis parameter, beta-thromboglobulin (beta-TG) and platelet factor IV (PF-4) as the platelet deterioration index, C3, C4, and CH50 as complement activation, coagulation function, fibrinolytic factor and thrombomodulin, nitric oxide (NO), and endothelin as endothelial deterioration. This system was very easily and simply controlled and had excellent response. Perioperative laboratory data were not markedly changed in either group. The Rota Flow demonstrated equivalent value of biocompatibility and hemolysis as compared with the BioMedicus BP-80, which is a standard centrifugal pump. After pumping, no thrombus formation or pivot wear was observed inside the pump. This atraumatic, small centrifugal pump is suitable not only for CPB but also for long-term circulatory support.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10886061     DOI: 10.1046/j.1525-1594.2000.06593.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  2 in total

1.  Hemolysis caused by surface roughness under shear flow.

Authors:  Osamu Maruyama; Yusuke Numata; Masahiro Nishida; Takashi Yamane; Ikuya Oshima; Yoshikazu Adachi; Toru Masuzawa
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.385

2.  Durability improvement of polymer chamber of pulsatile extracorporeal life support system in terms of mechanical change.

Authors:  Hyuk Choi; Seung Hoon Paik; Kwang Ho Lee; Byoung Goo Min; Yong Soon Won
Journal:  Med Biol Eng Comput       Date:  2007-08-25       Impact factor: 3.079

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.