BACKGROUND: A thoracic artificial lung, the MC3 Biolung, is being developed as a bridge to lung transplantation or as a treatment for acute respiratory insufficiency. METHODS: The thoracic artificial lung was tested in 10 sheep with the goal of 7 days of respiratory support. The sheep were recovered from surgery and monitored awake for 7 days. Hemodynamics, blood gases, blood cell counts, and organ function were recorded, and after 7 days, all sheep were euthanized and necropsied. RESULTS: Seven sheep survived the full duration. Cardiac output and mean arterial blood pressure were unchanged, averaging 4.7 +/- 0.8 L/min and 98 +/- 10 mm Hg, respectively. Arterial oxygen tension and device oxygen transfer rate were also unchanged, averaging 110 +/- 26 mm Hg and 97.7 +/- 35 mL/min, respectively. Arterial carbon dioxide tension was within normal ranges during the entire experiment, averaging 37.4 +/- 3.8 mm Hg. Artificial lung blood flow decreased from 51% +/- 14% of cardiac output on day 1 to 30% +/- 16% by day 7 because of changes in natural and artificial lung resistance. White blood cell counts were significantly elevated on days 5 and 7, and lastly, kidney and liver function remained normal, although signs of kidney infarction or hemorrhage were noted. CONCLUSIONS: The thoracic artificial lung is suitable for 7-day attachment, but improvements in blood biocompatibility are warranted.
BACKGROUND: A thoracic artificial lung, the MC3 Biolung, is being developed as a bridge to lung transplantation or as a treatment for acute respiratory insufficiency. METHODS: The thoracic artificial lung was tested in 10 sheep with the goal of 7 days of respiratory support. The sheep were recovered from surgery and monitored awake for 7 days. Hemodynamics, blood gases, blood cell counts, and organ function were recorded, and after 7 days, all sheep were euthanized and necropsied. RESULTS: Seven sheep survived the full duration. Cardiac output and mean arterial blood pressure were unchanged, averaging 4.7 +/- 0.8 L/min and 98 +/- 10 mm Hg, respectively. Arterial oxygen tension and device oxygen transfer rate were also unchanged, averaging 110 +/- 26 mm Hg and 97.7 +/- 35 mL/min, respectively. Arterial carbon dioxide tension was within normal ranges during the entire experiment, averaging 37.4 +/- 3.8 mm Hg. Artificial lung blood flow decreased from 51% +/- 14% of cardiac output on day 1 to 30% +/- 16% by day 7 because of changes in natural and artificial lung resistance. White blood cell counts were significantly elevated on days 5 and 7, and lastly, kidney and liver function remained normal, although signs of kidney infarction or hemorrhage were noted. CONCLUSIONS: The thoracic artificial lung is suitable for 7-day attachment, but improvements in blood biocompatibility are warranted.
Authors: David J Skoog; Joshua R Pohlmann; David S Demos; Christopher N Scipione; Amit Iyengar; Rebecca E Schewe; Ahmed B Suhaib; Kelly L Koch; Keith E Cook Journal: ASAIO J Date: 2017 Sep/Oct Impact factor: 2.872
Authors: Angela Lai; Caitlin T Demarest; Chi Chi Do-Nguyen; Rei Ukita; David J Skoog; Neil M Carleton; Kagya A Amoako; Patrick J Montoya; Keith E Cook Journal: Acta Biomater Date: 2019-04-03 Impact factor: 8.947
Authors: Shalv P Madhani; Brian J Frankowski; Sang-Ho Ye; Greg W Burgreen; William R Wagner; Robert Kormos; Jonathan D'Cunha; William J Federspiel Journal: ASAIO J Date: 2019-01 Impact factor: 2.872
Authors: Benjamin D Carr; Clinton J Poling; Pavel Hala; Matias Caceres Quinones; Aaron R Prater; Jennifer S McLeod; Robert H Bartlett; Alvaro Rojas-Pena; Ronald B Hirschl Journal: ASAIO J Date: 2020-05 Impact factor: 3.826