Literature DB >> 17720076

Anterior segment changes with age and during accommodation measured with partial coherence interferometry.

Alexis Tsorbatzoglou1, Gábor Németh, Noémi Széll, Zsolt Biró, András Berta.   

Abstract

PURPOSE: To evaluate anterior segment alterations with age and during accommodation in different age groups.
SETTING: Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary.
METHODS: Fifty-three subjects (101 normal eyes) were enrolled in this study and divided into 3 age groups: younger than 30 years (Group 1), between 31 years and 44 years (Group 2), and older than 45 years (Group 3). The total amplitude of accommodation was determined with a defocusing technique, and anterior segment measurements were performed by partial coherence interferometry.
RESULTS: Group 1 comprised 32 eyes; Group 2, 37 eyes; and Group 3, 32 eyes. The total amplitude of accommodation decreased with age (P<.0001). With the target position at infinity, the lens thickness (LT) and anterior segment length (ASL) increased and the anterior chamber depth (ACD) decreased significantly with age (P<.0001). During accommodation in the youngest group, the mean change in LT was 36.3 mum/diopter (D) and in ACD, -26.7 mum/D. The mean accommodation-induced ACD change was -0.08 mm +/- 0.06 (SD) in Group 1, -0.064 +/- 0.087 mm in Group 2, and -0.03 +/- 0.06 mm in Group 3 (P = .0004). The mean LT change during near fixation was 0.109 +/- 0.063 mm in Group 1, 0.103 +/- 0.136 mm in Group 2, and 0.006 +/- 0.05 mm in Group 3 (P<.0001). The mean ASL change during accommodation was 0.029 +/- 0.037 mm, 0.039 +/- 0.114 mm, and -0.023 +/- 0.051, respectively (P<.0001).
CONCLUSIONS: In addition to forward movement of the anterior lens surface with age, the posterior surface moved backward. Alterations in LT and ACD sufficient for a unit of refractive power change during accommodation might be smaller than previously thought. Anterior shifting of the lens may also participate in the accommodative response.

Mesh:

Year:  2007        PMID: 17720076     DOI: 10.1016/j.jcrs.2007.05.021

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  15 in total

1.  Objective evaluation of the changes in the crystalline lens during accommodation in young and presbyopic populations using Pentacam HR system.

Authors:  Yao Ni; Xia-Lin Liu; Ming-Xing Wu; Ying Lin; Yu-Ying Sun; Chang He; Yi-Zhi Liu
Journal:  Int J Ophthalmol       Date:  2011-12-18       Impact factor: 1.779

2.  Mechanism of accommodation assessed by change in precisely registered ocular images associated with concurrent change in auto-refraction.

Authors:  Andrzej Grzybowski; Ronald A Schachar; Magdalena Gaca-Wysocka; Ira H Schachar; Farhad Kamangar; Barbara K Pierscionek
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-16       Impact factor: 3.117

3.  Ocular anatomic changes for different accommodative demands using swept-source optical coherence tomography: a pilot study.

Authors:  José J Esteve-Taboada; Teresa Ferrer-Blasco; Miguel A Aloy; José E Adsuara; Pablo Cerdá-Durán; Petar Mimica; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-09-26       Impact factor: 3.117

4.  Comparison of anterior segment measurements with LenStar and Pentacam in patients with newly diagnosed glaucoma.

Authors:  Emine Sen; Merve Inanc; Ufuk Elgin; Pelin Yilmazbas
Journal:  Int Ophthalmol       Date:  2017-01-21       Impact factor: 2.031

5.  Objective measurement of accommodative biometric changes using ultrasound biomicroscopy.

Authors:  Viswanathan Ramasubramanian; Adrian Glasser
Journal:  J Cataract Refract Surg       Date:  2015-03       Impact factor: 3.351

6.  Pseudo-accommodation in non-amblyopic children after bilateral cataract surgery and implantation with a monofocal intraocular lens: prevalence and possible mechanisms.

Authors:  Charlotte Dénier; Pascal Dureau; Catherine Edelson; Amandine Barjol; Georges Caputo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-10-26       Impact factor: 3.117

7.  Anterior segment biometry during accommodation imaged with ultralong scan depth optical coherence tomography.

Authors:  Chixin Du; Meixiao Shen; Ming Li; Dexi Zhu; Michael R Wang; Jianhua Wang
Journal:  Ophthalmology       Date:  2012-08-17       Impact factor: 12.079

8.  Lens thickness with age and accommodation by optical coherence tomography.

Authors:  Kathryn Richdale; Mark A Bullimore; Karla Zadnik
Journal:  Ophthalmic Physiol Opt       Date:  2008-09       Impact factor: 3.117

9.  Biometry of anterior segment of human eye on both horizontal and vertical meridians during accommodation imaged with extended scan depth optical coherence tomography.

Authors:  Lin Leng; Yimin Yuan; Qi Chen; Meixiao Shen; Qingkai Ma; Beibei Lin; Dexi Zhu; Jia Qu; Fan Lu
Journal:  PLoS One       Date:  2014-08-12       Impact factor: 3.240

10.  Functional spasm of accommodation: Changes on scheimpflug imaging.

Authors:  Jaspreet Sukhija; Mangat R Dogra; Thara Zadeng; Jagat Ram
Journal:  Oman J Ophthalmol       Date:  2014-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.